Installation of a Zephyr Multi-Zone wall-mounted heat pump in Chomedey (Laval)
Zephyr MultiZone heat pump installed in Chomedey: dual-fan outdoor unit on brackets, discreet enclosure, three indoor zones for four-season comfort. AirGreen, HVAC experts Montreal–Laval–Rives.

In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
A Zephyr dual-fan unit designed to heat and cool multiple rooms, neatly integrated into a brick facade
In Chomedey , a residential area of Laval dominated by brick houses with semi-buried basements and narrow side walkways, we carried out the HVAC installation of a MultiZone Zephyr heat pump intended to serve several rooms of a single-family home. The environment presented typical constraints: tight passage between the house and the fence, proximity to an outdoor spa , vegetation to be preserved and an exposed foundation base. Our team orchestrated a safe and sustainable installation while preserving the aesthetics of the facade.
Context and needs of the house
The family wanted:
-
Replace spot cooling with four-season comfort in 3 main areas (living room, master bedroom, basement).
-
Reduce energy costs compared to portable appliances and electric baseboard heaters.
-
Minimize the footprint in the yard and comply with municipal and insurance requirements related to the proximity of the spa .
After calculating the thermal loads and validating the possible paths, we selected a Zephyr dual-fan outdoor unit coupled with wall-mounted heads with capacities adapted to each room. The configuration offers an excellent compromise between cold performance, quiet operation and distribution flexibility.
Choice and installation of the outdoor unit
The Zephyr unit is fixed on galvanized wall brackets anchored in the brick and raised in order to:
-
clear the air intake and exhaust grilles;
-
maintain the clearances prescribed by the manufacturer;
-
protect against snow accumulation and facilitate the flow of defrosting water;
-
reduce vibration transmission thanks to high-density silent blocks .
The chosen lateral location ensures free airflow despite the restricted space, while maintaining a safe distance from the spa (electrical standards and thermal clearances). The external disconnect panel is located within visual range, protected from water splashes.
Refrigerated route and drilling management
The refrigerant connections run along the rear facade, at waist height, then rise through discreet light-colored UV cladding to reach the entrances to the three rooms.
-
Estimated total length of the connections: 18 to 22 m, divided into three branches.
-
Curvature radii respected to preserve the refrigerant charge and limit pressure losses.
-
Clean holes with vapor barriers and insulating packing to maintain the airtightness of the envelope.
-
Controlled slopes for the flow of condensates on the interior side, promoting gravity drainage without a pump when possible.
This approach guarantees stable performance and avoids water pollution near the foundations.
Salient technical details
-
Machine type : MultiZone heat pump (multizone mini-split).
-
Brand : Zephyr (high flow dual-fan outdoor unit).
-
Supports : wall brackets with stainless steel hardware and anti-vibration pads .
-
Electricity : dedicated circuit with suitable circuit breaker, armoured cable to the external disconnector; earthing checked.
-
Condensates (interior): insulated pipes, controlled slope; discreet outlet on the rear side.
-
Winter management : defrost water discharge area prepared (draining stone bed), minimum clearance maintained in front of the lower fan.
Site features: brick, spa and existing tree
The brick wall requires proper anchors and a check of the condition of the air barrier. We have spaced out the fixing points to distribute the load and eliminate the risk of tearing.
The presence of a covered spa requires:
-
side clearance for maintenance and air circulation;
-
splash protection for wiring ;
-
strict management of conduits to avoid accidental contact with hot surfaces or cleaning products.
The bordering tree was preserved; we oriented the equipment to avoid recirculation of leaves in the grids and planned a seasonal maintenance plan .
Interior integration: three zones, three comforts
Each wall head has been calibrated according to volume, solar orientation and use:
-
Living room : airflow optimized for range, positioning avoiding direct blowing towards the rest area.
-
Master bedroom : silent night mode, fine temperature management .
-
Basement : stable cover of a more humid space; settings favoring dehumidification in summer.
Multi-zone control allows you to adjust the settings room by room, reducing electricity consumption and increasing the feeling of comfort.
Noise and vibrations: what we are putting in place
For homes in Laval, Montreal, Longueuil, North Shore and South Shore , sound perception is a recurring issue. We systematically apply:
-
elastomer pads under the outdoor unit;
-
tighten to the recommended torque to avoid buzzing;
-
direction of breath away from nearby windows ;
-
resonance test at the end of installation and rebalancing if necessary.
Result: discreet operation , compatible with neighboring uses and relaxation around the spa.
Safety, compliance and sustainability
-
Wiring protected in compliant conduits, service loops respected.
-
Sealing of the crossings with urethane and sealant compatible with air barrier.
-
Service valves and charge port accessible for future maintenance.
-
Commissioning documentation recording pressures, superheat, subcooling and measured currents .
Grants and Eligibility
High-performance multi-zone heat pumps may be eligible for incentives based on their efficiency class and cold-weather heating capacity . Our team assists homeowners in Greater Montreal to verify the criteria and submit applications when the chosen equipment meets them.
Recommended HVAC maintenance
To ensure the longevity of the heat pump :
-
clean the filters of the interior heads every 1 to 3 months;
-
clear 60 cm around the outdoor unit (leaves, snow, temporary objects);
-
avoid directing the air discharge towards light tarpaulins (e.g. spa cover);
-
schedule annual maintenance (refrigerant check, electrical tests, drainage, probes).
Regular maintenance maintains yields and reduces the risk of downtime during peak periods.
Result: zoned comfort and clean facade
The installation delivered to Chomedey offers:
-
stable winter heating and efficient summer cooling ;
-
careful integration into the brick without encroaching on the relaxation space;
-
easy maintenance thanks to clear access and commissioning documentation.
At AirGreen , we design each HVAC installation as a technical architecture project : adaptation to the site, compliance with regulations, clean finishes and lasting performance. Whether you are in Montreal , Laval , Longueuil , on the North Shore or the South Shore , our team guides you from the choice of heat pump to maintenance, with solutions aligned with your home and your uses.
How it goes, from the first call to the end
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
And at your place?
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
Which type of equipment for your project?
Pick what looks like your need.
Four mistakes we do not make
Flip each card to see what we do instead.
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
Useful pages for what comes next
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
Tell us about your house. We come and see it for free.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).