Installation of a Zephyr wall-mounted heat pump in Côte-des-Neiges–Notre-Dame-de-Grâce
AirGreen installs a Zephyr wall-mounted heat pump (R-32) in Côte-des-Neiges–Notre-Dame-de-Grâce: high head, short cooling path, gravity evacuation and measured commissioning. HVAC service in Montreal , Laval , Longueuil , North Shore and South Shore .

Take a tour of the installation
Each number is a point we check on site. Switch between summer and winter to watch air and heat move.
In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
Precise comfort and even diffusion: our HVAC installation of a Zephyr wall-mounted head (R-32) in a bright apartment in Côte-des-Neiges–Notre-Dame-de-Grâce
Project context and client expectations
At AirGreen , we are working in a dual-aspect apartment in Côte-des-Neiges–Notre-Dame-de-Grâce . The occupants want efficient cooling in the summer, comfortable additional heat in the spring and fall, and a discreet and quiet installation . The main room opens onto a central hallway; air circulation must therefore remain gentle to avoid creating cold air corridors near the passageways.
We recommend a recent Zephyr wall-mounted heat pump that runs on R-32 refrigerant : a robust choice with high seasonal efficiency and a reduced carbon footprint compared to older generations of R-410A. The Zephyr indoor head features a sleek front panel, central setpoint display, and a wide, multi-louvered air vent.
Sizing and logic of choice
Before proposing the capacity, we evaluate: surface area (approximately 28–32 m² for the living area), ceiling height, orientation, wall insulation and occupancy habits. The thermal profile indicates a 12,000 BTU solution (typical range for this volume), capable of covering the living room and supplying part of the hallway and the open kitchen.
Why this configuration?
-
Inverter modulation: maintaining the setpoint with low variations, without overconsumption;
-
Balance between blowing range and noise level;
-
Compatibility with the criteria of energy efficiency programs when they apply to the building;
-
Easy access to filtration for regular HVAC maintenance by occupants.
Interior installation: above the passage, without direct air current
We place the Zephyr head in the upper part, above a passage , with sufficient clearance from the ceiling for good air intake. This position allows:
-
a sweep of the room without blowing directly on the occupants;
-
a longitudinal diffusion which follows the circulation axis towards the adjacent spaces;
-
easy access to filters for cleaning.
The plate is anchored with dowels adapted to the support. The unit is perfectly plumb , which guarantees a regular flow of condensate and a quiet operation. The shutters and vanes are adjusted to create a wide cone of air, oriented towards the main volume rather than towards the door sill.
Refrigeration and drilling
We favor a direct rear drilling (“back-to-back” configuration) to limit the length of copper, reduce pressure losses and accelerate responsiveness. The wall-to-wall passage is sealed, insulated and then capped on the outside with a clean cover. The total length of connections is contained (approximately 2 to 3 m), which improves efficiency and simplifies maintenance.
The brazing is carried out under nitrogen flushing to prevent internal oxidation. After crimping to the recommended torques, we apply a high vacuum until a stable residual pressure is reached, then we open the valves and check for leaks.
Condensate management: priority to gravity
In this configuration, the condensate is evacuated by gravity , silently, with a constant slope and a passage protected against shocks. When lifting is necessary (unfavorable configuration or long distance), we offer a silent pump with a non-return valve. Here, the topography allows the most reliable and simplest solution.
Power on, settings and acoustic validation
Once the power supply has been checked (dedicated circuit, adequate gauge, tightening checked), we proceed with commissioning:
-
Current measurement and voltage control;
-
Verification of ΔT in cooling and auxiliary heating;
-
Mode settings: Auto/Cool/Heat/Dry, timer and auto restart;
-
Fine adjustment of the blowing to avoid drafts at the passage.
The front display allows you to check the setpoint and operating status at a glance. Within minutes, the room reaches the desired temperature, then the unit modulates to low speed; the noise level drops significantly, which is ideal for everyday life and quiet evenings.
Results: summer comfort and winter support
-
In summer, the Zephyr operates as a very economical wall-mounted air conditioner ; its dehumidification greatly improves perceived comfort without the need to excessively lower the setpoint.
-
In mid-season, Heat mode provides efficient support, reducing the need for the main heating system.
-
Inverter modulation limits on/off cycles , extends component life and stabilizes temperature.
Finishes and aesthetics
The interior finish remains discreet: thin line cover, clean seal, invisible wiring. The unit, installed above the passage, frees up the walls of fittings and respects the minimalist aesthetic of the apartment. We provide the client with the installation file with serial number , installation photos and maintenance instructions.
HVAC Maintenance: Maintaining Long-Lasting Performance
We recommend a simple and effective program:
-
Filters : vacuum/wash every 4 to 6 weeks during periods of intensive use;
-
Turbine and tank : periodic cleaning/disinfection to prevent odors and biofilm;
-
Annual inspection : pressures, evaporation/condensation temperatures, electrical tightening, sealing, condition of the line cover;
-
Exterior clearance : keep the unit free of any obstructions (vegetation, snow, objects).
Rigorous maintenance protects the exchanger, maintains air quality and ensures consistent seasonal performance .
Good usage practices
-
Realistic setpoint: 23–24°C in summer, 20–21°C for heating support;
-
Allow the device to modulate rather than switching off/on frequently;
-
Direct the flow towards the volume to be treated, never directly onto people;
-
Keep interior doors open to promote partial transfer of fresh air.
Mistakes to avoid
-
Installing a head too close to the ceiling or a lintel: air intake deteriorates;
-
Obstruct the unit with tall furniture or heavy curtains;
-
Forgetting to maintain filters: consumption increases and comfort drops.
AirGreen deadlines and process
-
Technical visit and detailed estimate (dimensioning, routing, options);
-
Planning and procurement;
-
Installation of the Zephyr head and connections (often in half a day for a single zone);
-
Commissioning with measurements, shutter adjustments and express training in use;
-
Follow-up : assistance with incentive procedures when the building and device meet the criteria, and scheduling maintenance appointments.
Grants and eligibility (according to criteria)
Recent, high-efficiency R-32 wall-mounted heat pumps may be eligible for energy efficiency incentives when official thresholds are met (performance, building configuration, usage). We help our clients build a clear case: proof of purchase, photos, installation certificates.
Why AirGreen for your project in Greater Montreal?
Our team installs, maintains and modernizes HVAC systems throughout Montreal , Laval , Longueuil , on the North Shore and the South Shore . Our signature: correct sizing, impeccable finishes, respect for clearances, measured commissioning and responsive after-sales service . Depending on the architecture of the home, we offer the right solution: wall-mounted heat pump , wall-mounted air conditioner , multi-zone, cassette or ducted.
In short : in Côte-des-Neiges–Notre-Dame-de-Grâce, the installation of a Zephyr R-32 wall-mounted heat pump, installed above the passageway with a short cooling path and gravity evacuation, provides stable comfort all year round, a neat aesthetic and controlled energy savings. A project by AirGreen, designed to last.
The big day, step by step
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What would it look like at your place?
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
Four mistakes we do not make
Flip each card to see what we do instead.
Your own project, step by step
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
Is your home ready?
Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.
Four statements: true or false?
It all comes down to details you have just seen.
1. In heating mode, the outdoor unit can produce water.
During defrost cycles. That water must drain away without forming ice.
2. You pick the capacity with a simple square-footage rule.
Windows, insulation, orientation and how the room is used all count. Capacity is chosen on site.
3. A multi-zone connects several indoor heads to a single condenser.
One head per room, all on the same condenser. Each room keeps its own temperature.
4. The disconnect can sit behind the patio furniture.
It must stay accessible: it is what shuts the unit off for service.
0 / 4 right answers
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
Every house has its constraints. We see them before we install.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).