Installation of a 2-head GREE FreeMatch R32 heat pump in Saint-Valentin: mounting the indoor wall unit
Installation of a 2-head GREE FreeMatch R32 heat pump in Saint-Valentin, with piping installed before the ceilings were closed: wall-mounted unit placement, condensate drain slope, and the minimum area required for R32. The AirGreen method, from Montreal to the South Shore.

Take a tour of the installation
Each number is a point we check on site. Switch between summer and winter to watch air and heat move.
In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
The component no one looks at that determines all the comfort
Homeowners assess a heat pump based on the outdoor unit: the brand on the casing, the capacity, the efficiency rating. Yet in everyday life, everything happens indoors. It is the wall-mounted head that distributes the air, makes noise or operates quietly, dries out a room or leaves it damp. A flawless outdoor unit connected to a poorly positioned head results in a disappointing system.
At Saint-Valentin, in Haut-Richelieu, we installed a GREE FreeMatch R32 2-head heat pump in a building undergoing renovation. The construction site gave us something we rarely get: the opportunity to run the piping before the ceilings were closed.
Take advantage of an open construction site: the best time for an HVAC installation
In the photo, the ceiling soffit is still open and the framing is exposed. This is exactly when an HVAC installation costs the least and delivers the best result.
When we work in a finished home, every metre of piping becomes a compromise: exposed conduit on the exterior wall, drilling into a corner of the room, a route longer than necessary. When we work during construction, we place the head where it belongs, not where the route happens to allow.
The tangible benefits on this project:
- Fully concealed piping in the soffit, with no exposed conduit indoors or visible raceway in the room.
- Shorter run between the outdoor unit and the indoor head, meaning less pressure loss and less additional refrigerant.
- Condensate drain with a pronounced, continuous slope, with the route planned before the drywall dictates its terms.
- Inspection possible of all connections before closing.
The advice that follows applies to any project in Montréal, Laval, or on the South Shore: if you are renovating and considering a heat pump within the next five years, have the piping installed now, even if the unit comes later. The marginal cost is negligible; retrofitting it later is not.
Where to place a wall-mounted head, and why
Height
The head is installed near the ceiling. This is not for aesthetic reasons: in cooling mode, the cold air produced is denser than the ambient air and naturally descends, circulating throughout the room. A head installed too low cools your ankles while leaving the upper part of the room warm.
However, the clearance required by the manufacturer above the unit must be maintained. A head installed tight against the ceiling restricts its own air intake and loses capacity, in addition to becoming noisy.
Side clearance
Here, the head is installed away from the corner where the walls meet. When placed too close to a perpendicular wall, the blower sends its airflow directly against the surface: the air bounces back toward the unit, and the internal thermostat reads a temperature that is not the room temperature. The result is always the same—the unit shuts off too soon, and the rest of the room never reaches the setpoint.
Airflow direction
A head should blow along the length of the room, never toward a nearby partition and never directly above a bed or work chair. Perceived comfort depends as much on the air speed you feel as on the temperature.
Heating mode changes the logic
In heating mode, warm air rises. A head installed high on the wall must therefore direct its louvers downward to push heat toward floor level. This is an adjustment we configure during commissioning, and one many homeowners overlook—they receive heat that stagnates at the ceiling and conclude that “the heat pump doesn't heat.”
The indoor installation mistakes we correct most often
The mounting plate fastened to drywall alone
The head and its mounting plate must be anchored to the framing. A plate held only by drywall anchors eventually starts to move, putting stress on the plumbing connections and the drain line. This is a common cause of indoor water leaks occurring two years after installation.
The drain’s back slope
The condensate drain works by gravity. It requires a continuous downward slope, without a single high point. A two-centimeter rise hidden above a ceiling soffit is enough to create a collection point where biological deposits form. The day it clogs, water flows out through the indoor unit’s drain pan and onto the wall. We check the slope every meter, not just at the ends.
The wall penetration without an outward slope
The wall penetration must be slightly sloped toward the outside and sealed. A level opening, or worse, one sloped inward, directs rainwater and runoff straight into the wall structure.
The forgotten caulking behind the wall plate
The area around the piping must be sealed on both the interior and exterior sides. An untreated air leak in this location creates condensation inside the wall cavity in winter—a form of damage that may not become apparent for several seasons.
The installed system
The dual-zone configuration of the GREE FreeMatch R32 can power two indoor units from a single outdoor unit. The unit’s reference data:
| Data | Value |
|---|---|
| Rated capacity | 24,000 BTU/h in both cooling and heating |
| Modulation | 7,500 to 31,400 BTU/h |
| Power supply | 208/230 V, MCA 19.5 A, MOP 25 A |
| Refrigerant | R32, outdoor unit A2L |
| SEER2 / HSPF2 / EER2 | 21 / 10 / 12 |
| Heating down to | -30 °C |
| Total piping | up to 60 m, elevation difference 15 m |
| Certifications | AHRI, ENERGY STAR Cold Climate, ETL |
| Warranty | 10 years on parts and compressor, +2 years with registration |
The R32 imposes a specific requirement inside the building, and this is what we systematically verify before choosing the location of an indoor unit: this refrigerant is classified as A2L, slightly flammable, which means there is a minimum room area based on the refrigerant charge served and the unit’s mounting height. A high-capacity indoor unit in a small, enclosed room is not always permissible. An installer who does not perform this calculation may install a non-compliant system without even realizing it.
Commissioning: the step too many contractors skip
Once the two heads are connected, we perform a deep vacuum evacuation, leak test, pressure and temperature checks in cooling and then heating mode, and record the parameters for each zone. We document these values. Without initial readings, no serious diagnosis is possible three years later—the technician servicing your system then has no reference point for determining whether it has drifted.
We also take the time to explain two settings that make a difference on your energy bill: maintaining a stable heating setpoint instead of making significant overnight setbacks, and cleaning the head filters every four to six weeks. A clogged filter reduces airflow, then capacity, then efficiency—and it is the most common cause of the service calls we receive.
Rebates and eligibility
The FreeMatch R32 is certified ENERGY STAR, Cold Climate, and AHRI, making it eligible for the categories covered by Quebec programs that provide assistance for efficient heating systems. The rule to remember: the AHRI number applies to the combination of the outdoor unit and indoor heads, never to the outdoor unit alone. We verify this combination and eligibility for the applicable program before signing, because financial assistance cannot be claimed retroactively when the application was put together incorrectly.
Our service area
At AirGreen, we handle HVAC installation from start to finish: load calculation, selection of the certified combination, indoor and outdoor installation, documented commissioning, and annual HVAC maintenance. We serve Montreal, Laval, Longueuil, the North Shore, the South Shore, and Montérégie, including small municipalities such as Saint-Valentin. A properly installed heat pump is noticeable because you forget it's there: no noise, no water, no cold drafts, and a lower energy bill.
The big day, step by step
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What would it look like at your place?
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
Four mistakes we do not make
Flip each card to see what we do instead.
Your own project, step by step
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
Is your home ready?
Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.
Four statements: true or false?
It all comes down to details you have just seen.
1. In heating mode, the outdoor unit can produce water.
During defrost cycles. That water must drain away without forming ice.
2. You pick the capacity with a simple square-footage rule.
Windows, insulation, orientation and how the room is used all count. Capacity is chosen on site.
3. A multi-zone connects several indoor heads to a single condenser.
One head per room, all on the same condenser. Each room keeps its own temperature.
4. The disconnect can sit behind the patio furniture.
It must stay accessible: it is what shuts the unit off for service.
0 / 4 right answers
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
Every house has its constraints. We see them before we install.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).