Installation of a Fujitsu Orion XLTH+ wall-mounted heat pump in Saint-Cyprien-de-Napierville
Balcony slab, concrete wall, and temperatures as low as -30°C expected: how we installed a Fujitsu Orion XLTH+ 12,000 BTU wall-mounted heat pump, from the anti-vibration ground stand to winter condensate drainage. Technical details and mistakes to avoid.
- City
- Region
- Equipment
- Brand
- Challenges
- Published
The job on one screen

The article, chapter by chapter
A balcony slab, a concrete wall, and -30 °C to anticipate: the anatomy of an installation that leaves no room for approximation
There are projects where the outdoor unit is placed on a plastic base in the backyard, three feet from the electrical panel, and everything is finished before lunch. This was not one of them.
At AirGreen, we installed a 12,000 BTU Fujitsu Orion XLTH+ wall-mounted heat pump in an upstairs apartment, with an outdoor unit that had to rest on a concrete balcony slab, backed against a load-bearing wall, a few feet from a window and a barbecue. Each of these constraints affects how the unit is mounted, drained, insulated, and commissioned. Here is how we approached it, and what it should teach you if you are considering a similar HVAC installation in Saint-Cyprien-de-Napierville, in Montérégie, or elsewhere on the South Shore.
The project context
The client heated with electric baseboards and was mainly suffering through the summer: south-facing orientation, large windows, and no air conditioning. The initial request was simple—“I want air conditioning”—but our assessment quickly showed that the real benefit lay elsewhere. With a coefficient of performance of 4.88, the same unit would also substantially reduce heating bills from October to April, provided the selected model could genuinely withstand a cold climate.
Three structural constraints guided the choice:
- No wall available for a wall-mounted support. The cladding and masonry could not support anchoring a cantilevered bracket without risking the transmission of vibrations into the structure—and therefore to the neighbor below.
- A circulation space to preserve. The balcony also serves as a terrace, so it was impossible to occupy its entire depth.
- Defrost condensate. In winter heating mode, an outdoor unit discharges water. On an elevated slab, this water can become a sheet of ice, cause water damage to the neighbour below, or both.
Why choose Fujitsu's Orion XLTH+ series
The AIRSTAGE H series from Fujitsu comes in three single-zone capacities: 09KTAP1, 12KTAP1, and 15KTAP1. We selected the 12KTAP1 after performing a load calculation, rather than reflexively oversizing the system.
Heating certified down to -30 °C, with no cutoff device
This is the most misunderstood criterion in the Quebec market. Many wall-mounted heat pumps advertise “cold-climate” operation but shut down at -15 °C or -20 °C. The Orion XLTH+ has a heating operating range of -30 °C to 24 °C, with no imposed cutoff point.
More important than the temperature range itself is the remaining capacity at those temperatures. For the 12KTAP1, it reaches:
- 156% of nominal capacity at -21 °C
- 103% of nominal capacity at -30 °C
In other words, the unit still delivers more than 15,000 BTU/h of heat in the coldest part of a January night. That figure—not the number printed on the box—is what determines whether your baseboard heaters will switch on or remain off.
The R-32 refrigerant and what it means for installation
The Orion XLTH+ uses R-32, whose global warming potential is 675, compared with 2,088 for R-410A—a reduction of 68%. The required charge is also lower for the same performance.
However, R-32 is classified as A2L, which requires checks that too many installers overlook: the minimum room area where the indoor unit is located, based on the total circuit charge, and full compliance with the CSA B52 standard. On this project, the living room was well above the required threshold, but we perform this calculation systematically even before ordering the equipment. A wall-mounted air conditioner installed in a 60 sq. ft. room may be non-compliant.
Quietness, durability, and control
- 23 dB(A) indoors in Quiet mode, with 6 fan speeds + Auto
- 48 dB(A) outdoors in cooling mode, 49 dB(A) in heating mode, with a low-noise outdoor operating mode—a practical advantage in a condominium
- ProCore™ indoor coils made of highly corrosion-resistant copper
- Integrated base pan heater, designed for extremely cold climates
- Built-in Wi-Fi with the AIRSTAGE app, and BACnet / Modbus compatibility for integration with a building management system
Technical specifications for the installed model (12KTAP1)
| Data | Value |
|---|---|
| Rated cooling capacity | 12,000 BTU/h (modulation from 3,100 to 17,300) |
| Rated heating capacity | 15,300 BTU/h (modulation from 4,500 to 27,300) |
| SEER2 | 31,5 |
| HSPF2 (region V) | 11,3 |
| EER2 | 16,7 |
| COP | 4,88 |
| Certification | ENERGY STAR (ES, ESCC, ESME) |
| Power supply | 208–230 V / 60 Hz / single-phase, 20 A circuit breaker |
| Indoor unit | 295 × 894 × 280 mm, 14 kg |
| Outdoor unit | 716 × 820 × 315 mm, 42 kg |
| Piping | Gas 3/8 in., liquid 1/4 in. |
| Piping length | 3 m min., 20 m max. (precharged up to 14.9 m) |
| Maximum elevation difference | 14,9 m |
| Dehumidification | 1.8 L/h |
| Filter | Washable |
The installation process, step by step
Ground mounting rather than wall mounting
We chose an extruded aluminum ground support with adjustable feet rather than a wall bracket. Three reasons:
- Vibration isolation. The feet rest on anti-vibration pads, not directly on the bare slab. The Inverter compressor therefore does not transmit low-frequency vibrations into the concrete structure, which would otherwise act as a resonance chamber for the floor below.
- Elevation. The unit is raised approximately 6 in. above the slab. In winter, it does not become trapped in a bed of ice formed by its own defrosting.
- Reversibility. No anchors passing through the cladding or the balcony membrane. A point that resolves many discussions with a condominium association.
The unit was positioned with its long side against the wall, the discharge grille facing outward, with full front clearance. A heat pump that blows against a solid railing or a wall that is too close recirculates its own air: efficiency drops and the machine defrosts more often.
Wall-mounted installation
The penetration goes through a concrete wall. We used a core drill with the exact diameter, an insulated sleeve, a slight slope toward the outside, and flexible sealant at both ends. The connection is then protected by an insulated black cover, visible in the photo at the bottom of the unit.
Even a slope reversed by just a few millimeters sends water back into the wall. It is one of the most common defects we correct in installations carried out by others in Montreal, Laval, and Longueuil.
Outdoor condensate drainage
A drain elbow was installed beneath the base pan and connected to a flexible hose directed toward the balcony drain rather than left to discharge freely. This part costs a few dollars. Its absence costs an insurance claim.
Refrigerant lines, vacuuming, and commissioning
- Cold-bending the 3/8 in. and 1/4 in. lines without crushing them, with continuous insulation on both pipes—including the liquid line, which is often neglected
- Re-making the flares with an eccentric flaring tool, and tightening to torque-wrench specifications
- Vacuuming down to a deep vacuum, with hold and rise testing: this is the step that determines the compressor's service life—and the one that gets shortened when someone wants to finish early
- Dedicated circuit, outdoor disconnect, verified grounding
- Checking the pressures, temperature split, and amperage draw, then configuring Wi-Fi AIRSTAGE and demonstrating it to the customer
Total time on site: one day.
Five mistakes we see constantly
- Oversizing. An oversized system short-cycles, dehumidifies poorly, and ages quickly. Load calculations are not a formality.
- Placing the outdoor unit against the wall or railing. The advertised performance assumes that proper clearance is maintained.
- Placing the outdoor unit directly on the slab. Ice, corrosion, and transmitted noise.
- Ignoring winter condensate. In heating mode, the outdoor unit produces water—not the other way around.
- Installing it too close to a barbecue. Airborne grease fouls the outdoor coil, and radiant heat throws off the sensor reading. We maintain a clear separation.
Maintenance: what the homeowner should do and what falls to us
- Every 2 to 4 weeks during the season: rinse the indoor unit's washable filters
- In spring: clear the outdoor grille of poplar fluff and dust
- Once a year: deep cleaning of the indoor unit's coil and drain pan, and checking pressures, drainage, and electrical connections
A dirty indoor coil reduces airflow, increases energy consumption, and eventually causes odors. This is the first thing we inspect during a service call for “loss of performance.”
Eligibility for rebates
The Orion XLTH+ is ENERGY STAR certified (ES, ESCC, ESME), which is the entry requirement for most programs currently available in Quebec, notably Hydro-Québec's LogisVert and Rénoclimat. The actual amount depends on the heating system being replaced, the type of building, and occupancy status—the rates change from year to year. We verify eligibility before signing, and we provide the technical documentation required for the application. We never promise an amount that we have not verified in the file.
What this project says about how we work
A successful wall-mounted heat pump installation is not judged on the day it is installed. It is judged at -25 °C in February, and six summers later. The decisions that make the difference—the ground stand rather than a wall mount, the slope of the core-drilled opening, the drainage elbow, and the depth of the void—cost a few hundred dollars and a few extra hours. They separate a machine that lasts fifteen years from one that turns into a warranty case.
AirGreen designs, installs, and maintains HVAC systems in Montréal, Laval, Longueuil, the North Shore, and the South Shore, including Saint-Cyprien-de-Napierville and the entire Jardins-de-Napierville RCM. We know the municipal noise and placement regulations specific to each area, and we verify them before proposing a location.
For an assessment of your home and a detailed quote for a Fujitsu Orion XLTH+, email us at sales@airgreen.ca or call (514) 316-2973. RBQ 5645-9605-01.
The job tools
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
How the job unfolds
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What we check on a job like this one
Each number is a point we check on site. Switch between summer and winter to watch air and heat move.
In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
Is your home ready?
Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.
Good habits, once the unit is in place
Six simple habits that keep the unit going. Your list stays on this device.
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
The right pages, at the right time
Four statements: true or false?
It all comes down to details you have just seen.
1. In heating mode, the outdoor unit can produce water.
During defrost cycles. That water must drain away without forming ice.
2. You pick the capacity with a simple square-footage rule.
Windows, insulation, orientation and how the room is used all count. Capacity is chosen on site.
3. A multi-zone connects several indoor heads to a single condenser.
One head per room, all on the same condenser. Each room keeps its own temperature.
4. The disconnect can sit behind the patio furniture.
It must stay accessible: it is what shuts the unit off for service.
0 / 4 right answers
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
An on-site estimate, the right capacity, the right equipment.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).