Installation of a Haxxair T2D Wall-Mounted Heat Pump in Saint-Eustache
Dive into a tale of trust and excellence with AirGreen’s recent installation of the Haxxair T2D in Saint-Eustache - a symphony of efficiency and silence tailored for satisfaction!

In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
A Symphony of Efficiency and Silence: The Haxxair T2D Experience
Meeting Unique Demands with Precision
In the serene locality of Saint-Eustache on the North Shore of Montreal, we at AirGreen recently had the pleasure of installing a Haxxair T2D Wall-Mounted Heat Pump for a valued customer of over a decade. This installation wasn’t just another routine job for us; it was a symphony of efficiency, silence, and precision, tailored to meet the unique demands of our client and his tenant.
The Silent Performer: Haxxair T2D
The narrow hallway of the rental apartment unit posed a challenge, demanding a compact yet powerful machine. The tenant’s sensitivity to noise added another layer of complexity to the requirement. Enter Haxxair T2D, a marvel of engineering that not only fits snugly in tight spaces but also whispers while it works, thanks to its ultra-silent mode.
- Cooling Capacity: A robust 12,000 BTU
- Heating Capacity: Effective even at -25°C
- Dimensions: Compact design with interior dimensions of 32.88 x 8.69 x 11 and exterior dimensions of 31.88 x 11 x 23
- Sound Pressure Level: With an interior sound level ranging between 26 and 39 dB(A), it’s a whisper in the room.
Quality That Speaks Volumes
Haxxair, a sub-brand of Hisense, is synonymous with quality. The T2D model is no exception, promising longevity with minimal downtime. It’s a straightforward, reliable machine designed to heat and cool efficiently, without unnecessary technological frills or components that are prone to failure.
Economic, Efficient, and Endorsed
Our client sought a machine that was neither the cheapest nor the most expensive but offered value for money. The Haxxair T2D hit the sweet spot with its competitive pricing and eligibility for a $375 Provincial Grant. Its Energy Star® certification and impressive 20.5 SEER efficiency rating further underscore its economic operation and environmental friendliness.
Warranty and Support
- Warranty: 10-10-10 warranty available for peace of mind
- Support: AirGreen’s unwavering support and maintenance services
A Decade of Trust and Satisfaction
For over ten years, our client has placed his trust in AirGreen for HVAC solutions. This installation of the Haxxair T2D is a testament to our commitment to delivering not just products, but solutions that resonate with the needs and expectations of our customers in Montreal, Laval, Longueuil, and the North and South Shores.
Conclusion: A Tale of Trust and Excellence
In the end, the installation at Saint-Eustache is not just about a machine; it’s a story of trust, excellence, and customer satisfaction. It’s about understanding the nuanced needs of our clients and responding with solutions that are efficient, economical, and exemplary. With the Haxxair T2D Wall-Mounted Heat Pump, we’ve added another chapter to our tale of commitment and quality at AirGreen.
How it goes, from the first call to the end
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
And at your place?
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
Which type of equipment for your project?
Pick what looks like your need.
Four mistakes we do not make
Flip each card to see what we do instead.
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
Useful pages for what comes next
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
Tell us about your house. We come and see it for free.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).
