The T2D still heats in deep cold: at −20 °C, the coldest test temperature in its NEEP record, it delivers up to 9,300 BTU/h for the 12,000 and 13,170 BTU/h for the 18,000. At Montréal-Trudeau, the daily minimum drops below −20 °C on just 12 days a year on average (1991–2020 normals). Pick a month and a size.
Montreal’s winter, month by month, against the T2D
Average daily minimum and cold days: 1991–2020 normals for Montréal-Trudeau. T2D output: the maximum in its NEEP record at each of its four test temperatures; in between, an AirGreen estimate by interpolation. T2D COP: kWh of heat delivered per kWh of electricity used.
−20−15−8.38.3−13.5 °C
T2D 18,000 at full output, at each NEEP test temperature
−20 °Cbrackets the month13,170 BTU/hCOP 1.792.2 kW drawn
−15 °Cbrackets the month13,770 BTU/hCOP 1.872.2 kW drawn
−8.3 °Cbrackets the month14,960 BTU/hCOP 2.281.9 kW drawn
8.3 °Cbrackets the month21,225 BTU/hCOP 2.912.1 kW drawn
In January, at the average daily minimum (−13.5 °C), the T2D 18,000 can deliver about 14,000 BTU/h at full output (AirGreen estimate, a straight line between −15 and −8.3 °C; the NEEP list gives no point in between). That month averages 20.7 days with a minimum below −10 °C and 6.7 below −20 °C.
Highlighted: the two T2D test temperatures that bracket the month. At full output, the COP falls with the cold to 1.79 at −20 °C for both sizes, from 3.08 (12,000) and 2.91 (18,000) at 8.3 °C. kW drawn: AirGreen calculation from the NEEP record (maximum output ÷ 3,412 BTU/h per kW ÷ COP).
Month by month at Montréal-Trudeau: average daily minimum and average number of days when the minimum drops below −10 °C and below −20 °C (1991–2020 normals, Environment and Climate Change Canada)
Month
Avg. min.
Below −10 °C
Below −20 °C
November
−1.7 °C
1.5
0.0
December
−8.7 °C
12.3
1.3
January
−13.5 °C
20.7
6.7
February
−12.4 °C
17.7
3.4
March
−6.5 °C
8.0
0.67
Normals: Environment and Climate Change Canada, Montréal-Trudeau (airport), 1991–2020 climate normals. Output and COP: NEEP list, records 33206 and 33207 (checked November 5, 2026), tests at 47, 17, 5 and −4 °F.
T2D SEER2 and HSPF2, NEEP list: seasonal efficiency in cooling and in heating, under the current method. In heating, the T2D 12,000 does better in region IV (9.5 vs 8.6), but the 18,000 takes the lead in region V, the colder of the two and the one Natural Resources Canada uses for a climate like Ottawa’s (7.27 vs 6.98); the higher the better.
LogisVert. Hydro-Québec’s LogisVert guide v1.10 (September 15, 2026) gives $120 (ENERGY STAR cold climate) or $50 (ENERGY STAR) per 1,000 BTU/h at −8 °C, for an outdoor unit of at least 12,000 BTU/h nominal cooling capacity. We use the heating capacity at 17 °F (−8.3 °C) from the ENERGY STAR record. This is an indicative amount. Only Hydro-Québec confirms the amount granted.
T2D heating, in BTU/h: HAXXAIR catalogue / NEEP list in each cell; NEEP lists these values at 8.3 °C
Size
Rated heating
Maximum heating
T2D 12,000
13,000 / 12,000
14,000 / 12,300
T2D 18,000
19,000 / 18,000
20,000 / 21,225
The HAXXAIR “Thermopompes & climatiseurs” (“Heat pumps & air conditioners”) brochure publishes the same heating outputs as the catalogue for both T2D sizes. The tool shows the NEEP values, the only ones that cover the T2D’s four test temperatures.
Did you know?
01
“Up to 23.3 SEER” (our translation), says the cover of the HAXXAIR “Thermopompes & climatiseurs” brochure: that is the SEER this document and the catalogue give the T2D 18,000, under the older method. The NEEP list, which gives the SEER2, under the current method, lists 22.5 for it: the two figures cannot be compared directly.
In cooling, HAXXAIR publishes 3.2 pt/h (pints per hour) of dehumidification for the T2D 18,000 and 2.5 pt/h for the 12,000: the 18,000 has 50% more cooling output, but removes only 28% more water per hour. Per 1,000 BTU/h of cooling, the 12,000 removes 0.21 pt/h and the 18,000 0.18 (AirGreen calculation).
HAXXAIR catalogue and brochure (same values)
03
According to the HAXXAIR “Thermopompes & climatiseurs” brochure, HAXXAIR heat pumps have “an energy-saving protection, which kicks in when the outdoor temperature reaches” −25 °C on the T series, the T2D’s series (our translation): it is also the bottom of the heating range the catalogue publishes for the T2D. HAXXAIR does not say what this protection does on the T2D.
The B2D shares the T2D’s R-410A and its 12,000 and 18,000 sizes. In the catalogue, HAXXAIR publishes equal or higher rated heating for it; for cold weather, only the T2D has outputs listed on NEEP, the ones in the tool above. In cooling, the T2D has the better EER, the efficiency at full load.
For several rooms on one outdoor unit, the HAXXAIR multi-zone systems we install (HVHM-18T2D to HVHM-42T2D) are also T2D series; their NEEP cold-weather output is on the Multi-zone page.
Warranty as published by HAXXAIR
Residential. “Five-year warranty on parts and compressor for a residential installation.” (our translation)
Commercial. “One-year warranty on parts and five-year warranty on the compressor for a commercial installation.” (our translation)
HAXXAIR product catalogue. Per the catalogue, it applies to all current models in Canada. Our quote states what applies to your installation.
Frequently asked questions
Is the T2D enough for the coldest days in Montreal?
HAXXAIR publishes T2D heating down to −25 °C, but its NEEP record stops at −20 °C: below that, no output is published. On those nights, about 12 a winter at Montréal-Trudeau (the minimum reached −31.8 °C on January 27, 1994, the record for the 1991–2020 period), keep a backup heat source. Above that, the heat loss of your rooms, assessed during the site visit, tells whether the T2D is enough.
Why is the LogisVert grant higher for the T2D 18,000 than for the 12,000?
For two reasons: only the 18,000 is ENERGY STAR cold-climate certified, which is worth $120 per 1,000 BTU/h instead of $50, and its ENERGY STAR record gives it more rated output at −8.3 °C: 10,000 BTU/h against 7,500. That makes $1,200 (AHRI 204628476) against $375 (AHRI 204628475); the higher maximum in its NEEP record does not enter our calculation. Both are indicative amounts for the T2D: only Hydro-Québec confirms the amount granted.
How much electricity does the T2D use in deep cold?
For an 8-hour night at −20 °C at full output: about 17 kWh for the T2D 18,000 and 12 kWh for the 12,000 (AirGreen calculation, same method as the tool, × 8 h, not counting the heating element in the outdoor unit’s base pan). Electric baseboards would use about 31 and 22 kWh (same heat, at COP 1).
Between the 12,000 and the 18,000, we decide on site, based on the rooms to heat; the price also depends on the line length and wall access. Request a quote and we’ll come and take a look.