AirGreenHAXXAIR

Sold and installed by AirGreen.Montreal, Laval, Longueuil, South Shore and North Shore

HAXXAIR central heat pumps · 2 to 5 tons · R-410A

HAXXAIR central heat pump, 2 to 5 tons: how loud, how big outside?

HAXXAIR’s catalogue publishes 54 dB(A) for the outdoor unit of our 2-ton central heat pump and 68 dB(A) for the 5-ton unit. Pick a size: the tool compares its published level with the other sizes, then gives its footprint and weight. Further down: cold-weather heating for each size and the LogisVert amount for our 4-ton listing.

The HVHD outdoor unit, size by size: published sound and footprint

The levels HAXXAIR publishes for its central heat pumps, compared with each other. dB(A): decibels adjusted to how the human ear hears.

Central heat pump size

HVHD-36E2D, 3 tons: 56 dB(A) as published by HAXXAIR, 2 dB(A) more than the 2-ton and 12 dB(A) less than the 5-ton. Outside, the unit takes up 94.9 × 34.0 cm on the ground (37-3/8 × 13-3/8 in), stands 83.8 cm (33 in) tall and weighs 156 lb.

HAXXAIR does not say at what distance its levels are measured: use them to compare the sizes with each other. To place these figures, Québec.ca notes that sleep can be disturbed by outdoor noise of 40 dB(A); with no published measuring distance, this is only a rough guide, and the unit’s location is chosen at the site visit. The footprint is the unit alone: HAXXAIR does not publish the clearances to leave around the HVHD outdoor unit.

Sound level published by HAXXAIR for the outdoor unit, in dB(A)

  • 2 tons HVHD-24E2D54 dB(A)
  • 3 tons HVHD-36E2D56 dB(A)
  • 4 tons HVHD-48E2D2not published
  • 5 tons HVHD-60E2D68 dB(A)

Scale from 30 to 80 dB(A)

1 m2 tons86.0 cm67.0 cm5 tons94.9 cm138.7 cm3 tons94.9 cm83.8 cm
Front of the HVHD outdoor unit (width × height), to scale; dashed: the other sizes. The 4-ton is not drawn: HAXXAIR does not publish the dimensions of the HVHD-48E2D2 model on our listing.

Sound levels, dimensions (width × depth on the ground, then height) and weights: HAXXAIR catalogue (2-, 3- and 5-ton sizes), weights as published, in pounds. Drawing: HVHD front width × height, to scale.

The four HAXXAIR central heat pumps, compared by size

The HAHD air handler for each size is on the electric furnace page. Our 4-ton product listing carries models with the E2D2 suffix (HVHD-48E2D2 and HAHD-48E2D2), which appear in neither HAXXAIR’s catalogue nor its brochure, both printed with the E2D suffix only: this size’s values come from its NEEP listing (505154) and its ENERGY STAR record. Those of the 2-, 3- and 5-ton sizes come from the catalogue.

See HAXXAIR electric furnaces

SizeAHRIENERGY STAR CanadaNominal capacityHeating at −8.3 °CSeasonal efficiencyMinimum circuit ampacity (MCA) / max. fuseLogisVert, indicative amount
2 tonsHVHD-24E2D205306853no record24,000 BTU/h15,300 BTU/hSEER 18 · HSPF 1015 / 25 Ano amount
3 tonsHVHD-36E2D205726755no record36,000 BTU/h25,000 BTU/hSEER 18 · HSPF 1123 / 35 Ano amount
4 tonsHVHD-48E2D22070364733627529 · cold climate48,000 BTU/h (NEEP)31,000 BTU/h (NEEP)SEER2 17.5 · HSPF2 8.5 (region IV, NEEP)not published$3,720
5 tonsHVHD-60E2D205921369no record56,000 BTU/h36,400 BTU/hSEER 17.5 · HSPF 1035 / 60 Ano amount

Nominal capacity: the same in cooling and in heating at 8.3 °C (47 °F) for each size. 5-ton: the catalogue’s table gives 56,000 BTU/h, while the title of its page announces “60 000 BTU/H”. Efficiency: HAXXAIR’s catalogue publishes SEER (cooling) and region IV HSPF (heating); the NEEP list publishes SEER2 and HSPF2, measured with another method, so they do not compare directly with the first two; in both cases, higher is better. AHRI numbers of the four central units: our product pages.

LogisVert. Hydro-Québec’s LogisVert guide v1.10 (September 15, 2026) gives $120 (ENERGY STAR cold climate) or $50 (ENERGY STAR) per 1,000 BTU/h at −8 °C, for an outdoor unit of at least 12,000 BTU/h nominal cooling capacity. We use the heating capacity at 17 °F (−8.3 °C) from the ENERGY STAR record. This is an indicative amount. Only Hydro-Québec confirms the amount granted.

For our 4-ton (AHRI 207036473, ENERGY STAR 3627529, cold climate): 31,000 BTU/h × $120 ÷ 1,000 = $3,720. This amount is for the complete system, outdoor unit and air handler of the same size; under guide v1.10, replacing only one of the two units is not eligible.

See the LogisVert conditions on our HAXXAIR page

HAXXAIR central or multi-zone, at 24,000 and 36,000 BTU/h

At the same nominal heating output at 8.3 °C, two ways to spread the heat: an HAHD air handler and ducts for the central heat pump, an indoor head in each room for the HVHM multi-zone. HAXXAIR publishes a heating range that goes lower for the central unit, but no output below −8.3 °C; for the multi-zone, the NEEP list gives an output at −15 °C (see the multi-zone page), and the AHRI numbers of our HVHM multi-zone units have an ENERGY STAR cold-climate record, which can make them eligible for LogisVert.

FeatureCentral 24,000 HVHD-24E2DMulti-zone 24,000 HVHM-24T2DCentral 36,000 HVHD-36E2DMulti-zone 36,000 HVHM-36T2D
Indoor units1 HAHD air handler and ducts2 or 3 zones1 HAHD air handler and ducts2 to 4 zones
Nominal heating at 8.3 °C24,000 BTU/h24,000 BTU/h36,000 BTU/h36,000 BTU/h
Nominal cooling24,000 BTU/h24,000 BTU/h36,000 BTU/h32,000 BTU/h
Heating at −8.3 °C15,300 BTU/h (catalogue)15,000 BTU/h (NEEP; max. 26,000)25,000 BTU/h (catalogue)22,400 BTU/h (NEEP; max. 40,000)
Heating at −15 °Cnot publishedon the multi-zone pagenot publishedon the multi-zone page
Published heating rangedown to −30 °Cdown to −25 °Cdown to −30 °Cdown to −25 °C
ENERGY STAR Canadano record3542753 · cold climateno record3542752 · cold climate

HAXXAIR catalogue (central and multi-zone units); cold-weather heating of the multi-zones: NEEP list (records 425471 and 425474), nominal and maximum output at −8.3 °C; multi-zone AHRI numbers: our product pages, found on NEEP and ENERGY STAR.

See HAXXAIR multi-zone units

Did you know?

The outdoor unit can be far from the HAHD air handler: HAXXAIR publishes up to 164 ft (50.0 m) of refrigerant piping for the 2-ton and 246 ft (75.0 m) for the 3- and 5-ton sizes, with a 98 ft (29.9 m) height difference for all three.

HAXXAIR catalogue

In cooling, the 2-ton central unit slows down to 6,700 BTU/h, under a third of its nominal 24,000 BTU/h; in heating at 8.3 °C, the 3-ton runs from 8,900 to 38,200 BTU/h, above its nominal 36,000 BTU/h (our calculation).

HAXXAIR catalogue

According to its HAXXAIR brochure, the central heat pump’s coils are helium-tested for leaks under 500 psi of air pressure (about 3,450 kPa, our conversion).

HAXXAIR brochure “Thermopompe centrale” (“Central heat pump”) (undated)

Warranty as published by HAXXAIR

Residential. “Five-year warranty on parts and compressor for a residential installation.” (our translation)

Commercial. “One-year warranty on parts and five-year warranty on the compressor for a commercial installation.” (our translation)

HAXXAIR product catalogue. The catalogue says it applies to all current models in Canada; its central heat pump page adds “warranty on all parts” (our translation). Our quote states what applies to your installation.

Frequently asked questions

Which HAXXAIR central heat pump can qualify for LogisVert?

Since November 26, 2025, LogisVert only accepts ENERGY STAR certified heat pumps. No ENERGY STAR record carries the AHRI numbers of our 2-, 3- and 5-ton heat pumps: only the 4-ton, installed with its air handler, can qualify, subject to Hydro-Québec’s list of eligible heat pumps, which is the final word.

What is the lowest outdoor temperature for heating with a HAXXAIR central heat pump?

HAXXAIR publishes a heating range of −30 to 24 °C (−22 to 75 °F) for its 2-, 3- and 5-ton central units, with no output published below −8.3 °C. For the 4-ton, the NEEP list gives at most 33,600 BTU/h at −15 °C (5 °F), with a COP (coefficient of performance) of 1.9, and 17,000 BTU/h at −25 °C (−13 °F), its coldest test temperature, with a COP of 1.5: even that cold, each kWh it uses still gives 1.5 kWh of heat. On the coldest days, the HAHD air handler’s element tops up the heat: see the electric furnace page. For context: the 1991–2020 climate normals for Montréal-Trudeau airport (ECCC) count an average of 0.21 days a year, about one day every five years, with a minimum below −30 °C.

Can I keep the line set from my old central heat pump?

Possibly, if the pipe sizes and condition are right: HAXXAIR publishes a 3/8 in liquid line for its 2-, 3- and 5-ton central units, and a 5/8, 3/4 and 7/8 in gas line respectively. We take the existing line set into account in the central heat pump quote, after the site visit.

Which indoor units can the HAXXAIR central heat pump be installed with?

HAXXAIR’s central heat pump brochure shows three: an “A-coil” or a “cased-coil” indoor coil, or the HAHD “indoor blower cabinet” (our translation). Our product listings pair each HVHD outdoor unit with its HAHD air handler: the AHRI numbers of our central units, the 4-ton’s ENERGY STAR record and its LogisVert amount all belong to that pairing, and the electric element is in that air handler.

Sources

Price of an installed HAXXAIR central heat pump

The installed price depends on the size, the HAHD air handler and the ducts in place. Request a quote and we’ll come and take a look.