AirGreenHAXXAIR

Sold and installed by AirGreen.Montreal, Laval, Longueuil, South Shore and North Shore

V2D series · R-454B · ENERGY STAR cold climate

HAXXAIR V2D R-454B wall-mounted heat pump: heating range from mild weather to deep cold

The V2D is the R-454B HAXXAIR wall series we install, ENERGY STAR cold-climate certified in all four sizes. At −25 °C, the NEEP list still gives it up to 5,000 BTU/h for the 9,000 and 11,700 BTU/h for the 24,000. Pick a size and a temperature to see how far it slows down, its rated output and its maximum.

V2D modulation range, as listed on NEEP

The minimum shows how far the V2D slows down, the maximum what it can deliver. NEEP test temperatures: 8.3 °C, −8.3 °C, −15 °C and −25 °C. HAXXAIR publishes a heating range of −25 to 25 °C for the V2D.

Size
Outdoor temperature
Minimum
6,020 BTU/h
Rated output at this temperature (NEEP)
22,000 BTU/h
Maximum
24,000 BTU/h
COP at maximum
1.85

At −8.3 °C, the V2D 24,000 slows down to 6,020 BTU/h; its NEEP rated output there is 22,000 BTU/h, and it can deliver up to 24,000 BTU/h.

On the bar, the vertical mark shows the rated output. COP: heat delivered per kWh of electricity used.

Minimum and maximum of each size, in BTU/h (NEEP list)

Size8.3 °C−8.3 °C−15 °C−25 °C
V2D 9,0003,000–10,0002,550–9,2002,000–9,0001,000–5,000
V2D 12,0003,000–13,0002,550–12,0002,000–11,0001,000–6,100
V2D 18,0005,500–19,0004,675–18,5004,000–18,0002,000–11,500
V2D 24,0007,000–25,0006,020–24,0005,000–19,8002,500–11,700

Data from the NEEP list (records 203875 to 203878, checked November 5, 2026). NEEP test temperatures: 47, 17, 5 and −13 °F.

The four V2D sizes, record by record: AHRI, NEEP, ENERGY STAR and LogisVert

ModelAHRINEEPENERGY STAR CanadaSEER2HSPF2 (region IV / V)LogisVert grant, indicative amount
V2D 9,000 BTU/h2160120102038753723079 · cold climate2511 / 9not eligible (under 12,000 BTU/h)
V2D 12,000 BTU/h2160120112038763723080 · cold climate2310 / 9$1,296
V2D 18,000 BTU/h2158873412038773712562 · cold climate2110 / 8.5$2,160
V2D 24,000 BTU/h2158873422038783712561 · cold climate22.59.5 / 8$2,640

AHRI numbers: HAXXAIR V2D brochure; each points to the NEEP and ENERGY STAR records shown. SEER2 and HSPF2 (NEEP list): seasonal cooling and heating efficiency; the higher the better, and region V stands for a colder climate than region IV.

LogisVert. Hydro-Québec’s LogisVert guide v1.10 (September 15, 2026) gives $120 (ENERGY STAR cold climate) or $50 (ENERGY STAR) per 1,000 BTU/h at −8 °C, for an outdoor unit of at least 12,000 BTU/h nominal cooling capacity. We use the heating capacity at 17 °F (−8.3 °C) from the ENERGY STAR record. This is an indicative amount. Only Hydro-Québec confirms the amount granted.

Since November 26, 2025, LogisVert no longer uses the NEEP list. For the V2D, as for any heat pump, only ENERGY STAR certification counts. Hydro-Québec’s list is final; the other conditions are in the guide and on our HAXXAIR page.

V2D: the heating values that differ between the HAXXAIR brochure and the NEEP list (brochure / NEEP)

SizeRegion V HSPF2Max. heating, BTU/h (NEEP: at 8.3 °C)Max. at −25 °C, BTU/hCOP at −25 °C
V2D 9,0009.1 / 910,700 / 10,0005,500 / 5,0001.47 / 1.22
V2D 12,0009.2 / 913,800 / 13,0006,000 / 6,1001.53 / 1.38
V2D 18,0007.7 / 8.521,900 / 19,00012,000 / 11,5001.59 / 1.43
V2D 24,0007.7 / 826,300 / 25,00012,000 / 11,7001.41 / 1.37

For the V2D 18,000, the brochure also prints 18,000 instead of 18,500 BTU/h at −8.3 °C, and 10,000 BTU/h at −15 °C, less than its 12,000 at −25 °C; the NEEP list gives 18,000 at −15 °C. We show the NEEP values throughout: it is the only source giving the minimum, rated and maximum output at all four temperatures for all four V2D sizes.

Did you know?

The HAXXAIR V2D brochure mentions the outdoor unit’s condensate-pan heater, which prevents ice and snow from building up, without a wattage; the NEEP list puts it at 150 W for the V2D 9,000 and 12,000, 200 W for the 18,000 and 250 W for the 24,000.

HAXXAIR V2D brochure, NEEP list

At −25 °C, the V2D 24,000 gives barely more than the 18,000: the HAXXAIR brochure prints 12,000 BTU/h for both, the NEEP list 11,700 vs 11,500. The gap widens as it gets milder: 24,000 vs 18,500 BTU/h at −8.3 °C.

HAXXAIR V2D brochure, NEEP list

At −8.3 °C and full output, the HAXXAIR brochure gives the V2D 12,000 a COP of 2.51, the best of the four sizes: 2.07 for the 9,000, 1.95 for the 18,000 and 1.85 for the 24,000. On the V2D, bigger does not mean more efficient in the cold.

HAXXAIR V2D brochure (the NEEP list gives the same values)

V2D or T2D, size for size

The T2D, using R-410A, is the other ENERGY STAR-certified HAXXAIR wall series we install. In the cold, the V2D delivers more at full output: at −8.3 °C, 12,000 vs 10,100 BTU/h for the 12,000, and 18,500 vs 14,960 for the 18,000. For refrigerant, the cold-climate designation and SEER2, where the T2D 18,000 has the better figure, see the decoder on our HAXXAIR page.

FeatureV2D 12,000T2D 12,000V2D 18,000T2D 18,000
AHRI216012011204628475215887341204628476
Minimum at 8.3 °C3,000 BTU/h3,115 BTU/h5,500 BTU/h5,330 BTU/h
Maximum at −8.3 °C12,000 BTU/h10,100 BTU/h18,500 BTU/h14,960 BTU/h
Maximum at −15 °C11,000 BTU/h9,600 BTU/h18,000 BTU/h13,770 BTU/h
COP at maximum, at −15 °C2.01.851.91.87

Data from the NEEP list; T2D AHRI numbers: our product sheets, found on NEEP and ENERGY STAR.

See the T2D series

Warranty as published by HAXXAIR

Residential. “Five-year warranty on parts and compressor for a residential installation.” (our translation)

Commercial. “One-year warranty on parts and five-year warranty on the compressor for a commercial installation.” (our translation)

HAXXAIR V2D brochure. Our quote states what applies to your installation.

Frequently asked questions

Which V2D size should I choose?

The V2D size is chosen on site, based on the room and the house. What sets the sizes apart, per the NEEP list: in mild weather (8.3 °C), the V2D 9,000 and 12,000 slow down to 3,000 BTU/h, the 18,000 to 5,500 and the 24,000 to 7,000; in the cold (−15 °C), they reach 9,000, 11,000, 18,000 and 19,800 BTU/h. Oversized, a V2D 24,000 therefore cannot slow down as far as a 12,000 in mild weather: it stops and restarts more often.

Which size keeps the largest share of its output at −15 °C?

Per the NEEP list, the V2D 9,000 and 18,000 still deliver all of their 8.3 °C rated output at −15 °C (9,000 and 18,000 BTU/h). The 12,000 gives 11,000 BTU/h out of 12,000, and the 24,000, 19,800 out of 24,000.

And below −25 °C?

HAXXAIR publishes no heating data for the V2D below −25 °C, and the NEEP list also stops at −25 °C. For the coldest days, keep a backup heat source alongside the V2D; we discuss it during the site visit. Montréal-Trudeau’s 1991–2020 climate normals do not count days below −25 °C: our T2D page gives the days below −20 °C, which include them.

Sources

Price of an installed V2D

The size is chosen during the site visit; the price also depends on the line and access. Request a quote and we’ll come and take a look.