Job sheet · Project

Installation of a Haxxair T2D Wall-Mounted Heat Pump in Senneville, Montreal

Dive into AirGreen's latest installation in Senneville, Montreal. Discover the quiet, efficient, and affordable Haxxair T2D Wall-Mounted Heat Pump, tailored for Quebec winters!

By AirGreen Climatisation & Chauffage Admin3 min read
City
Region
Equipment
Brand
Challenges
Published
–chapters, to open one by one
3 minto read the whole story
–type of installation
2023year published
At a glance

The job on one screen

Installation of a Haxxair T2D Wall-Mounted Heat Pump in Senneville, Montreal
Installation of a Haxxair T2D Wall-Mounted Heat Pump in Senneville, Montreal
The full story

The article, chapter by chapter

A Seamless Experience with AirGreen's Expertise

Choosing the Perfect Fit

When it comes to ensuring comfort in your home, the right choice of HVAC equipment is paramount. Our recent installation in Senneville, Montreal stands as a testament to this. Our client was in search of a machine that was not only efficient but also quiet, affordable, and backed by a solid warranty. After careful consideration, the Haxxair T2D Wall-Mounted Heat Pump emerged as the clear winner.

Why Haxxair T2D?

  • Tailored for Quebec Winters: Manufactured by Hisense, the Haxxair T2D is designed keeping in mind the harsh Quebec winters. Its robust build ensures optimal performance even in the coldest of days.

  • Ultra Quiet Mode: One of the standout features of this model is its Ultra Quiet mode. This ensures that the compressor, even when placed close to the entrance, operates without causing any disturbance. A boon for those who cherish their peace and quiet!

  • Efficiency and Warranty: With an impressive 20.5 SEER efficiency rating and a 10-10-10 warranty (Compressor - Parts - Labor), this machine promises both performance and peace of mind.

  • Space-Saving Design: The compact design of the Haxxair T2D ensures that it doesn't occupy too much space, making it an ideal choice for balconies and other tight spaces.

The Installation Process

The installation at Senneville was a straightforward affair, thanks to the simplicity of the model and the expertise of our team at AirGreen. Our client was particularly pleased with the rapidity of the installation process. The strategic placement of the compressor near the entrance not only saved space but also reduced costs.

A Glimpse into the Machine's Features

  • Cooling and Heating Capacities: The machine boasts a cooling capacity of 12,000 BTU and can efficiently heat even at temperatures as low as -25°C.

  • Serial Numbers: For those keen on specifics, the interior serial number is HAH-12T2D and the exterior is HVH-12T2D.

  • Dimensions: The interior unit measures 32.88 x 8.69 x 11 inches, while the exterior unit comes in at 31.88 x 11 x 23 inches.

  • Connectivity and Efficiency: The machine is Energy Star® certified and offers optional WiFi connectivity. Its AHRI number is 204628475.

  • Sound Levels: With a sound pressure level of 26 / 39 dB(A) for the interior, it's evident why our client was so impressed with its quiet operation.

  • Other Technical Details: The machine operates on 220V voltage and uses R-410A gas (Freon). The pipes used are 1/4 - 3/8 inches.

A Win-Win Situation

Our client was not only able to benefit from the Provincial Grant of $375 but was also thrilled with the overall installation experience. The Haxxair T2D proved to be the perfect blend of efficiency, affordability, and quiet operation. It's installations like these that reinforce our commitment to delivering the best HVAC solutions in Montreal, Laval, Longueuil, North Shore, and South Shore.

In Conclusion

At AirGreen, we pride ourselves on our ability to understand our clients' needs and provide solutions that not only meet but often exceed their expectations. The installation in Senneville is a shining example of this. Whether you're in the market for a new HVAC system or simply looking to upgrade, we're here to guide you every step of the way.

Your numbers

The job tools

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    The steps

    How the job unfolds

    The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

    Step 1 of 9The on-site estimate

    We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

    1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
    2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
    3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
    4. The wall openingA single opening, with the slope the drain needs to flow outside.
    5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
    6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
    7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
    8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
    9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
    The tour

    What we check on a job like this one

    Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

    Generic diagram: wall-mounted heat pump, indoor and outdoor units

    In summer, the outdoor unit rejects the house's heat outside.

    Generic illustration of this type of installation, not a survey of this job site. Tap a number.

    1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

    2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

    3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

    4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

    5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

    6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

    7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    Maintenance

    Good habits, once the unit is in place

    Six simple habits that keep the unit going. Your list stays on this device.

    0 / 6 checked
    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    For your project

    The right pages, at the right time

    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. In heating mode, the outdoor unit can produce water.

    2. You pick the capacity with a simple square-footage rule.

    3. A multi-zone connects several indoor heads to a single condenser.

    4. The disconnect can sit behind the patio furniture.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    An on-site estimate, the right capacity, the right equipment.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment