Installation of a Sharp ZU1 Wall-Mounted Heat Pump in Deux-Montagnes, North Shore
Transform your home with the Sharp ZU1 heat pump! Experience unmatched comfort and significant energy savings with our latest installation.

In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
Harnessing Efficiency and Comfort with Advanced Technology
The Sharp ZU1: A Leap Forward in HVAC Technology
Nestled in the tranquil surroundings of Deux-Montagnes on Montreal's North Shore, a recent installation by AirGreen has set a new benchmark for residential comfort and energy efficiency. The centerpiece of this installation is the Sharp ZU1, a wall-mounted heat pump that has rapidly become the preferred choice for discerning homeowners. With its robust 18,000 BTU cooling and heating capabilities and a suite of advanced features, the ZU1 model promises not just comfort but also a significant reduction in energy bills.
The Machine's Specifications and Features
The Sharp ZU1 is a testament to the innovation that defines modern HVAC systems. It operates with a revolutionary R-32 refrigerant, known for its low environmental impact and superior efficiency. This system not only cools and heats at a remarkable -27°C, but also incorporates cutting-edge technologies:
- Plasmacluster Technology: Enhances indoor air quality by neutralizing airborne pathogens and allergens, ensuring a healthier living environment.
- COANDA Airflow Control: Distributes air evenly throughout the space, avoiding direct airflow to occupants, which enhances comfort without the direct draft sensation.
- Efficiency Ratings: With a SEER rating of 24.0, it ranks among the most efficient heat pumps available, further backed by an Energy Star® certification.
- Silent Operation: The indoor unit operates at a noise level of just 25 dB(A), making it one of the quietest in its class.

Installation Details and Customer Experience
The installation at Deux-Montagnes was not just about adding a heat pump; it was about transforming a living space into a haven of comfort and efficiency. The Sharp ZU1 was installed in a central location within the home to optimize its airflow and cooling/heating distribution. The outdoor unit, with dimensions 33.47 x 13 x 27.94 inches, was strategically placed to minimize aesthetic impact while maximizing performance.
A key part of this installation story is the integration with Hilo thermostats, which allows the homeowners to qualify for a $2640 LogisVert Grant by Hydro-Québec. This incentive, coupled with a 25% additional bonus, not only makes the installation more affordable but also encourages the adoption of energy-efficient technologies.
Unique Installation Challenges and Solutions
Every installation comes with its own set of challenges, and the Deux-Montagnes project was no exception. The primary challenge was integrating the new system with the existing infrastructure without disrupting the home's aesthetics or functionality. AirGreen's technicians used their expertise to ensure that the installation was seamless, with minimal impact on the home's interior design.
The installation also required careful consideration of the system's placement to ensure optimal functionality. The indoor unit was placed high on a wall to provide better air distribution and to keep it out of reach of children, ensuring safety and efficiency.
Why Choose AirGreen for Your HVAC Needs?
Choosing AirGreen means more than just getting a new HVAC system; it means partnering with experts who are committed to providing tailored solutions that meet your unique needs. Here are some reasons to choose us for your next HVAC project:
- Expertise: Years of experience installing various types of HVAC systems in homes across Montreal and its surrounding areas.
- Customization: Every installation is customized to meet the specific needs and preferences of our customers.
- Support: Ongoing support and maintenance services to ensure your system continues to perform at its best.
At AirGreen, we understand that installing a new HVAC system is a significant investment, and we are dedicated to making the process as smooth and beneficial for our clients as possible. With our expertise and commitment to quality, we ensure that every installation is a step toward a more comfortable and sustainable home.
How it goes, from the first call to the end
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What the unit delivers when it is cold
The range as published on airgreen.ca: pick a size to see its capacity in deep cold.
| Size | Heating at −8 °C | Heating at −15 °C | Coldest certified point | COP at −15 °C | SEER | HSPF | Indicative LogisVert aid |
|---|---|---|---|---|---|---|---|
| Sharp ZU1 12 000 | 14,500 | 12,000 | −27 °C: 7,200 | 2.11 | 22.0 | 11.0 | $1,740 |
| Sharp ZU1 15 000 | 18,100 | 15,300 | −27 °C: 10,100 | 2.1 | 24.0 | 11.0 | $2,172 |
| Sharp ZU1 18 000 | 22,000 | 18,000 | −27 °C: 11,500 | 2.2 | 24.0 | 11.0 | $2,640 |
| Sharp ZU1 24 000 | 22,400 | 19,000 | −27 °C: 12,300 | 2.2 | 22.0 | 11.0 | $2,688 |
According to NEEP, it delivers 14,500 BTU/h at −8 °C (17 °F), more than at 8 °C (14,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 7,200 BTU/h, 60% of its nominal 12,000 BTU size.
At 8 °C, its certified maximum capacity reaches 17,100 BTU/h, 42% more than its nominal 12,000 BTU size.
According to NEEP, it delivers 18,100 BTU/h at −8 °C (17 °F), more than at 8 °C (18,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 10,100 BTU/h, 67% of its nominal 15,000 BTU size.
At 8 °C, its certified maximum capacity reaches 21,800 BTU/h, 45% more than its nominal 15,000 BTU size.
According to NEEP, it delivers 22,000 BTU/h at −8 °C (17 °F), more than at 8 °C (21,600 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its COP at −27 °C is 1.88: the highest of the ZU1 line, which ranges from 1.79 to 1.82 at that temperature.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 11,500 BTU/h, 64% of its nominal 18,000 BTU size.
At −27 °C, its certified minimum capacity is 3,200 BTU/h (5,500 at 8 °C). It slows down instead of cycling on and off.
According to NEEP, its certified heating capacity at −15 °C (5 °F) is 19,000 BTU/h, 79% of its nominal 24,000 BTU size. Its COP there is 2.20.
Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.
And at your place?
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):
Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.
Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
Which type of equipment for your project?
Pick what looks like your need.
Four mistakes we do not make
Flip each card to see what we do instead.
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
Useful pages for what comes next
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
Tell us about your house. We come and see it for free.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).