Project

Relocating a Daikin wall-mounted heat pump in a Rosemont–La Petite-Patrie plex

A client's wall-mounted Daikin relocated and reinstalled by AirGreen in Rosemont–La Petite-Patrie: discreet integration on a masonry wall, on the top floor of a plex. HVAC service for all of Greater Montreal.

By AirGreen Climatisation & Chauffage Admin5 min read
Relocating a Daikin wall-mounted heat pump in a Rosemont–La Petite-Patrie plex
Relocating a Daikin wall-mounted heat pump in a Rosemont–La Petite-Patrie plex
–chapters in this story
5 minreading time
–type of installation
2026year published
The tour

Take a tour of the installation

Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

Generic diagram: wall-mounted heat pump, indoor and outdoor units

In summer, the outdoor unit rejects the house's heat outside.

Generic illustration of this type of installation, not a survey of this job site. Tap a number.

  1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

  2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

  3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

  4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

  5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

  6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

  7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

The job

A careful relocation that combines comfort, sobriety and performance

At AirGreen , we carry out HVAC installations tailored to everyday Montreal living. This project highlights the relocation of a Daikin wall-mounted heat pump in a bright apartment in Rosemont–La Petite-Patrie , where the client's primary requirement was clear: improve four-season comfort without encroaching on the minimalist aesthetic of the space.

The owner had bought this Daikin wall-mounted heat pump some time ago and wanted it moved. We removed the existing unit and reinstalled it at the new location.

Context and objectives of the project

The apartment, located on the top floor of a typical Rosemont apartment building, benefits from good thermal inertia but quickly became hot in the summer and too cool in the spring and fall.


An exemplary HVAC installation, thought out in detail

Study of implantation and air circulation

Before any drilling, we validate:

  • the installation height (close to the ceiling, while respecting the clearance required for air suction);

  • the blowing axis towards the living room in order to cover the space evenly without creating annoying air currents;

  • the proximity of an exterior wall to limit the length of refrigeration connections and facilitate the evacuation of condensate.

The chosen positioning allows the motorized shutter to direct the flow in width and depth, for rapid and homogeneous air mixing.

Drilling and fixing on masonry wall

Installing a wall head on a brick/concrete support requires suitable anchors:

  • Laser tracing, leveling to the nearest millimeter;

  • Use of expansion anchors and anti-corrosion screws;

  • Exact-diameter through-hole for refrigeration lines, communication cable, and condensate drain—all sloped slightly outward for reliable gravity drainage .

This approach avoids vibrations, guarantees the longevity of the fixings and preserves the integrity of the wall.

Refrigeration lines, power supply and finishing

  • Route shortcuts : “back-to-back” exit to the outside, minimizing the length of piping;

  • Brazing and flaring to standards, with nitrogen leak testing and deep vacuum to protect the compressor;

  • Communication cable sized to actual length, routed neatly;

  • Discreet exterior capping , matching the color of the facade;

  • Addition of an external disconnect switch for safe maintenance of the condenser;

  • Check the drip-loop and the slope of the drain to avoid any backflow.

The result: understated finishes that are visually invisible and easy to maintain.

Commissioning and checks

  • Pressure and temperature control using digital tools;

  • Calibration of airflow and louver angles according to room configuration;

  • Tests in cooling and heating modes;

  • Validation of noise level and absence of vibrations.

An installation report is given to the customer, with recommendations for use and maintenance.


Construction site challenges and AirGreen solutions

1) Masonry support and cleanliness of the drilling

Drilling a hard wall into a finished housing requires precision and dust control . We use diamond core bits , HEPA vacuums , and localized protection . The interior is left clean, with no chips around the line crossing.

2) Clearances and ceiling lighting

The chosen wall sits beneath a clean white ceiling. We adhered to the manufacturer's recommended overhead and side clearances to optimize suction and avoid any interaction with lighting, which could cause turbulence or harsh shadows.

3) Aesthetics and visual continuity

The client wanted to keep things simple : the exterior pipe cover was chosen in a light shade , and the internal connections are invisible. The unit blends into the room's white palette , while remaining accessible for maintenance.


AirGreen Best Practices for a Sustainable Wall-Mounted Heat Pump

Responsible sizing

An oversized system shortens its cycles, loses efficiency and prematurely wears out its compressor. We size according to:

  • of the actual air-conditioned surface ;

  • solar exposure and insulation quality ;

  • Montreal's specific winter heating needs .

Minimal but regular maintenance

  • Filters : monthly dusting during periods of intensive use;

  • Exchanger : annual gentle cleaning to maintain efficiency;

  • Condensate : check the slope and flow in spring;

  • Outdoor unit : clear grilles, snow guard if exposed to snowdrifts.

We offer HVAC maintenance plans tailored to residences in Montreal, Laval, Longueuil, North Shore and South Shore .

Wise use

  • In summer, favor a stable setting rather than extreme back and forth movements;

  • In winter, keep interior doors open to promote diffusion;

  • Set realistic setpoints (e.g. 22–23°C depending on preference and humidity).


Why AirGreen in Rosemont–La Petite-Patrie (and throughout Greater Montreal)

  • Local expertise : mastery of the specific features of Montreal plexes and condos;

  • RBQ licence, qualified team and proven methods: leak testing, vacuum drawing, instrumented commissioning;

  • Turnkey service : from heat pump selection to HVAC maintenance , including grant assistance ;

  • Transparency : detailed quote, clear intervention schedule, follow-up after installation.


The result: discreet comfort and added value

This relocation of a wall-mounted Daikin in Rosemont–La Petite-Patrie demonstrates that a well-planned project offers comfort without visual compromise. The apartment now enjoys its heat pump in the new location, summer and winter. For similar projects in Montreal, Laval, Longueuil, on the North Shore and the South Shore , AirGreen remains your trusted partner: advice, precision of execution and attentive monitoring.

The steps

The big day, step by step

The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

Step 1 of 9The on-site estimate

We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

  1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
  2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
  3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
  4. The wall openingA single opening, with the slope the drain needs to flow outside.
  5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
  6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
  7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
  8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
  9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
Your numbers

What would it look like at your place?

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    Mistakes avoided

    Four mistakes we do not make

    Flip each card to see what we do instead.

    Going further

    Your own project, step by step

    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. In heating mode, the outdoor unit can produce water.

    2. You pick the capacity with a simple square-footage rule.

    3. A multi-zone connects several indoor heads to a single condenser.

    4. The disconnect can sit behind the patio furniture.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    Every house has its constraints. We see them before we install.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment