Central heat pumps in Quebec: six 3-ton models compared side by side

10 min
Comparison · Central heat pumps · 3 tons

Six 3-ton central heat pumps, side by side, with no ranking

Article published June 18, 2025 · updated November 17, 2026

BOSCH, FUJITSU AIRSTAGE, GOODMAN, GREE, LENNOX and ZEPHYR: six 36,000 BTU/h central heat pumps sold by AirGreen, all on A2L refrigerant. They are shown in alphabetical order of the brand. The values come from the AHRI certificates published by NEEP and, where a certificate is missing, from the manufacturer's documents, always identified. You choose the order in which to read them.

6 models · 3 nominal tonsR-32 and R-454B refrigerants5 AHRI certificates read on NEEP on November 17, 2026No ranking
Estimated operating cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for the same 36,000 BTU/h house in Montréal, at Hydro-Québec Rate D, taxes included. The five certified heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Their certified cooling capacities range from 32,000 to 36,000 BTU/h: the calculation uses the common nominal size, 36,000 BTU/h. The GOODMAN has no certificate published by NEEP and no HSPF2 Region V for this combination; it stays out of the calculation. Electric baseboards serve as the reference point.

How this amount is calculated
  1. Heat needed over the winter. A house whose heat loss reaches 36,000 BTU/h ( kW) at −23.1 °C, Montréal's design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for heating around the clock, all winter. Heating degree-days (base 18 °C) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours a day (the “Heating” slider), the heat is reduced in the same proportion, for the heat pump as for the baseboards: a simplification that ignores the recovery after a temperature setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup planned for when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 36,000 BTU/h ÷ SEER2 × hours a day × 60 days ÷ 1,000: the method of Hydro-Québec's air-conditioning calculator, with the seasonal SEER2 efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day: a maximum, since a variable-speed unit slows down once the room is at the right temperature.
  4. Price. Hydro-Québec Rate D in effect April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ above; the average price, 9.104¢, is the one Hydro-Québec's calculators use. GST and QST included. The system access charge, the same with or without a heat pump, is not counted.

AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The actual bill depends on the house, the insulation, the settings and the use; this amount is not a promise.

Your order

A list that sorts by what matters in your home

The 2025 version of this article gave each brand a rank. Here, the list starts in alphabetical order and you do the sorting. Pick a measure: the six bars move into place. A unit with no comparable value for that measure drops below the dotted line, with the reason.

Extreme cold

From 8.3 to −30 °C: what is published for each one

Pick a temperature. Each card shows, in this order: a NEEP-certified point, otherwise a manufacturer value outside the certificate, otherwise the range between the two published values on either side of that temperature, otherwise the last published value with what the manufacturer says beyond it. Capacities are maximum heating capacities.

Reading the chart. Circles are NEEP-certified points; diamonds are values published by the manufacturer outside the certificate. The coldest certified point is not at the same temperature from one unit to the next (−20, −25, −26.1 or −30 °C): at those points, the values do not compare with each other. At −15 °C, all five certificates have a point at the same place.
Before choosing

Four checks that apply to all six

The earlier version of this article already gave this advice. It stays, backed by what the documents let you check.

The size comes from the house calculation

Three tons means 36,000 nominal BTU/h of cooling. The right size follows from the house's heat loss at −23.1 °C, Montréal's design temperature, not from floor area alone. An oversized unit starts and stops more often.

The existing ducts matter

A central heat pump pushes air through the house's ducts. Leaks or narrow ducts reduce what reaches the rooms; they are inspected before choosing the unit.

SEER2 and HSPF2 are read on the certificate

Each model's AHRI number is printed above. Type it into the NEEP database (ashp.neep.org) to read the same values as this page, and the capacities at 8.3, −8.3 and −15 °C.

The quote must name the exact combination

A certificate covers one outdoor unit with one specific indoor unit. Both model numbers on the quote must match those on the certificate.

Documented features

What each manufacturer writes, line by line

A “not stated” cell means the document consulted does not say; it is not proof that the feature is absent.

Swipe the table left to see all six columns.

Sound

Six outdoor units, six ways of publishing sound

dB(A)

How to read these figures. dB(A) measures a noise level as the ear perceives it: the lower the number, the quieter the unit. Each value is the one the manufacturer publishes for the outdoor unit.

Why this is not a ranking. These figures are not measured the same way: sound pressure at 1 m for one, anechoic chamber for another, method not stated elsewhere. Different method — not comparable.

Measurements taken by each manufacturer with its own method: read them separately, not as a ranking.

Installation

Piping, dimensions and electrical protection

The limits printed in the manuals and submittals. The installer confirms them on site for the chosen combination.

Swipe the table left to see all six columns.

Frequently asked questions

What people ask about these six central systems

Why six models and not a list of ten?

The 2025 version of this article gave a rank to ten brands. This page keeps the brands AirGreen sells as central heat pumps on A2L refrigerant and shows one 3-ton model per brand, with no ranking. At AirGreen, ACD and COMFORTMAKER central units are offered on R-410A only: they are not compared here. The TRANE RunTru A5HP5 had no NEEP record and no heating capacities in its ODR-PSD035A data sheet as of November 17, 2026; it is covered on another page, linked below.

Why these models for each brand?

One 3-ton model sold by AirGreen, on R-32 or R-454B, for each brand. For BOSCH, the IDS Premium Connected, the series the earlier article named; for GREE, the FLEXX ULTRA; for ZEPHYR, the R-454B version. One model's values do not describe the whole brand.

Why does the GOODMAN have no amount in the cost section?

The GLZS4MA3610 + AMST36CU1300 combination carries AHRI number 215213866, which could not be found in the NEEP database on November 17, 2026. Without a certified HSPF2 Region V or SEER2 for this combination, the calculation method does not apply. The GOODMAN data sheet publishes a heating table at 8.3, −8.3, −15 and −17.8 °C: it appears in the Extreme cold section, marked “per the manufacturer”.

The certified capacities are not all 36,000 BTU/h. Why?

In cooling at 35 °C, the certificates give 34,200 BTU/h (BOSCH), 36,000 (FUJITSU AIRSTAGE), 34,000 (GREE), 36,000 (LENNOX) and 32,000 (ZEPHYR). “3 tons” is the nominal size. The cost calculation uses 36,000 BTU/h for all five, the same house for each.

Can the coldest points be compared?

Not directly. Each certificate gives its coldest point at its own temperature: −20 °C for BOSCH and LENNOX, −25 °C for ZEPHYR, −26.1 °C for FUJITSU AIRSTAGE, −30 °C for GREE. The “coldest certified point” sort orders the temperature, not the capacity.

What happens below the stated heating range?

According to the BOSCH manual, below −20 °C the heat pump calls for the electric backup if one is installed. The other documents give their stated range without quantifying capacity beyond it. In a house heated by a central system, a backup (electric furnace or heating elements) takes over when the heat pump is no longer enough.

Are they eligible for grants?

LogisVert eligibility depends on Hydro-Québec's official list in effect on the purchase date and on the installed combination. This page promises no amount; the current list is checked at the time of the quote.

Certified data

All AHRI and NEEP values

Swipe the table left to see all six columns.

higher marks the higher value of the same measure, under the same conditions. It is not a recommendation. Capacities and COP by temperature, and the coldest point, are not highlighted. The GOODMAN column gives the values from the manufacturer's data sheet, outside any certificate: they are never highlighted.

All six are on AirGreen's website.

To choose for your house, talk it over with our team: bring the floor area, the condition of the ducts and your current heating.

Sources and documents

Where each figure comes from

NEEP, record 423152 (BOSCH IDS Premium Connected)AHRI 214771711 · accessed November 17, 2026 NEEP, record 306746 (FUJITSU AIRSTAGE CENTAURI XLTH)AHRI 217895717 · accessed November 17, 2026 NEEP, record 392095 (GREE FLEXX ULTRA)AHRI 215213330 · accessed November 17, 2026 NEEP, record 406900 (LENNOX MMPD)AHRI 216581339 · accessed November 17, 2026 NEEP, record 389447 (ZEPHYR ZE-636HPA)AHRI 215381146 · accessed November 17, 2026
BOSCH, installation manual BTC 762003301 D02.2025 · heating range −4 to 86 °F, backup below −4 °F, piping · IDS Premium Connected brochure 76H991891B (1-25): modulation 35 to 138%
FUJITSU AIRSTAGE, submittal 36KUAH1MVersion 20260123A · range −15 to 75 °F, piping, dimensions, protection, sound
GOODMAN, data sheet SS-GLZS4M-R3204/24 · heating table with AMST36CU1300 at 47, 17, 5 and 0 °F, piping, MCA/MOP, weight, sound
GREE, FLEXX ULTRA R32 brochure (032725) and FXU36 submittal (05162025)Range −22 to 75 °F, piping, dimensions, sound · EXTENDED RATINGS table (08272024), p. 5: maximum capacity from 0 to −20 °F, outside AHRI conditions
LENNOX, MMPD Engineering Handbook, form 211078December 2025 · range −4 to 75 °F, piping, MCA/MOCP, sound at 1 m
ZEPHYR, installation manual 4285663-BRange −22 to 75 °F, piping, height difference, footprint
Hydro-Québec, Electricity RatesApril 1, 2026, Rate D, sec. 2.5 · estimated operating cost NRCan, HOT2000 climate map, Montréal Intl4,167 degree-days (18 °C), −23.1 °C design
You made it to the end.Share it with someone it could help.
Keep reading

In the same blog

AirGreen Climatisation & Chauffage

From reading to your home.

An AirGreen advisor assesses your situation on site, free of charge, and gives you a quote within 24 hours.

  • RBQ licence 5645-9605-01Subclasses 15.8, 15.10 and 16
  • Free on-site estimateAn advisor assesses your needs
  • Quote within 24 hoursClear and detailed

4 comments

Gilles Gravel
Gilles Gravel

Moi j’ai 77ans, je pense que M.Bouchard pose la bonne question $$$

Gilles Gravel
Gilles Gravel

comment démèler tout ca

Gilles Gravel
Gilles Gravel

comment démèler tout ca

Claude Bouchard
Claude Bouchard

goodman 2 1/2 tonne central combien $ tout compris avec subvention ou 2 tonne maison 25 par 35 pieds carre standart

Leave a comment