Head to head · Indoor units

GREE, MIDEA and SAMSUNG floor consoles in Longueuil: three 12,000 BTU models compared

8 min
Comparison · floor consoles · 12,000 BTU

Three 12,000 BTU floor consoles for a Longueuil home, figure by figure

GREE All Match R32, MIDEA MFA and SAMSUNG Premium: three consoles sold by AirGreen, mounted low on the wall like a baseboard. What each one costs to run, what it publishes in deep cold, how it fits under a window and what its certified record says, without naming a winner.

Refrigerant: R-32 (GREE, SAMSUNG) · R-454B (MIDEA)Sold as: 12,000 BTUENERGY STAR cold climate: yes for all three (NEEP)
AirGreen product card GREE All Match R32
GREE · ALL MATCH R32

Floor console, 12,000 BTU

CON12HP230V1R32AH · VIR12HP230V1R32AO
AHRI 215415566 · NEEP 388975

Same outdoor unit as the GREE All Match R32 12,000 360° cassette sold by AirGreen.

See the product page
AirGreen product card MIDEA MFA
MIDEA · MFA SERIES

Floor console, 12,000 BTU

MFAHU-H12B-2A · MO1HS-H12B-2A
AHRI 215471433 · NEEP 387306

The only one of the three on R-454B (GWP 466). MFA series in the NEEP record.

See the product page
AirGreen product card SAMSUNG Premium
SAMSUNG · CONSOLE PREMIUM

Floor console, 12,000 BTU

AC012DNJDCG · AC012DXSCCG
AHRI 216441749 · NEEP 406917

The LENNOX MFMD012S6 console with the MMLD012S6S unit publishes the same rated values (Lennox submittal 496404, Jan. 2025).

See the product page

Brands in alphabetical order; on these AirGreen product cards the ENERGY STAR logo is hidden.

Estimated running cost

What the electricity costs, in dollars, winter and summer

A console often heats a room that used to run on baseboards. Baseboards are therefore the starting point; set the price per kWh and the operating hours.

Under the window

Does the console fit under your window?

The three consoles are drawn to scale on a 48 in wall. Enter the height of the bottom of your window: the clearance shows for each one.

The drawing shows only the unit. Each manufacturer's installation manual sets the clearances around the console, and the route for piping and drain is checked on site.

Deep cold

What each console publishes, from mild weather to −30 °C

The certified value at each temperature when it exists; otherwise, the two published points around it or the last published point, without interpolation.

TemperatureGREE All Match R32MIDEA MFASAMSUNG Premium
8.3 °CFall and spring · 47 °F

14,000 BTU/h max. · rated 12,000 · COP 3.78NEEP certified

16,100 BTU/h max. · rated 12,000 · COP 3.86NEEP certified

19,500 BTU/h max. · rated 13,000 · COP 3.40NEEP certified

−8.3 °CJanuary mean: −9.2 °C (Montréal-Trudeau) · 17 °F

12,000 BTU/h max. · rated 10,000 · COP 2.79NEEP certified

12,400 BTU/h max. · rated 9,800 · COP 2.71NEEP certified

13,200 BTU/h max. · rated 7,600 · COP 2.45NEEP certified

−15 °CJanuary mean daily low: −13.5 °C · 5 °F

10,000 BTU/h (rated = max.) · COP 1.90NEEP certified

11,300 BTU/h (rated = max.) · COP 1.88NEEP certified

10,400 BTU/h (rated = max.) · COP 1.80NEEP certified

−23.1 °CMontréal-area design temperature (NRCan)

Between 6,500 and 10,000 BTU/h10,000 at −15 °C and 6,500 at −30 °C (NEEP); nothing is interpolated in between.

Between 4,800 and 11,300 BTU/h11,300 at −15 °C and 4,800 at −30 °C (NEEP); nothing is interpolated in between.

Between 6,500 and 10,400 BTU/h10,400 at −15 °C and 6,500 at −25 °C (NEEP); nothing is interpolated in between.

−25 °C−13 °F

Between 6,500 and 10,000 BTU/h10,000 at −15 °C and 6,500 at −30 °C (NEEP); nothing is interpolated in between.

Between 4,800 and 11,300 BTU/h11,300 at −15 °C and 4,800 at −30 °C (NEEP); nothing is interpolated in between.

6,500 BTU/h max. · COP 1.61NEEP certified; only the max. value is published at this temperature

−30 °C−22 °F

6,500 BTU/h max. · COP 1.42NEEP certified; only the max. value is published at this temperature

4,800 BTU/h max. · COP 1.04NEEP certified; only the max. value is published at this temperature

Last published point: 6,500 BTU/h at −25 °CColder than −25 °C, neither NEEP (record 406917) nor the documents we checked give a figure for this combination.

certified max.certified ratedrange between two published pointslast published point, warmer

A console heats the room it sits in first. Below the last published point, or if the room loses more heat than the value shown, backup heat takes over.

Certified data

The three records, line by line

FeatureGREE All Match R32MIDEA MFASAMSUNG Premium
Certification
AHRI certificate · NEEP record215415566 · NEEP 388975215471433 · NEEP 387306216441749 · NEEP 406917
RefrigerantR-32 (GWP 675)R-454B (GWP 466)R-32 (GWP 675)
ENERGY STAR cold climateYes (NEEP record)Yes (NEEP record)Yes (NEEP record)
Certified efficiency (NEEP)
SEER223.025.021.0
EER213.012.512.2
HSPF2 region IV9.010.59.5
HSPF2 region V (cold climate)8.08.37.6
Rated capacity at 35 °C12,000 BTU/h12,000 BTU/h10,200 BTU/hsold as a 12,000; NEEP certified value
Rated heating capacity at 8.3 °C12,000 BTU/h12,000 BTU/h13,000 BTU/h
Rated COP at 8.3 °C3.783.863.40
Maximum capacity at −15 °C10,000 BTU/h11,300 BTU/h10,400 BTU/h
COP at −15 °C1.901.881.80
NEEP turndown ratiomax. at −15 °C ÷ min. at 8.3 °C3.262.573.59
Outdoor unit and installation
Base pan heater (defrost)Yes, 72 W (NEEP)Yes, 150 W (NEEP)Yes, 150 W (NEEP)
Outdoor sound level52 dB(A)55.5 dB(A)54 dB(A)
Outdoor unit, W × D × H31.58 × 13.78 × 21.84 in31.69 × 12.99 × 21.81 in31.13 × 11.19 × 21.63 in
Maximum line length66 ft82 ft66 ft
Maximum height difference40 ft49 ft49 ft
Line set diameters, liquid / gas1/4 – 3/8 in1/4 – 3/8 in1/4 – 3/8 in
Console (indoor unit)
Console, W × D × H27.56 × 8.47 × 23.63 in31.26 × 7.87 × 24.45 in28.38 × 7.81 × 24.38 in
Console weight33 lb33 lb35 lb
Maximum airflowmax. 441 CFMmax. 441 CFMmax. 318 CFM
Indoor sound level, min. / max.29 / 45 dB(A)24 / 44 dB(A)24 / 38 dB(A)
Dehumidification2.96 pints/h3.13 pints/hNot stated on the AirGreen page
Wi-FiOptionalOptionalYes, built in
Power supply208/230 V208/230 V208/230 V

Certified values: NEEP records 388975, 387306 and 406917 (checked Nov. 17, 2026). Dimensions, weight, piping, airflow, sound levels, dehumidification and Wi-Fi: taken from the manufacturers' documents on AirGreen's product pages.

Noise

Sound at floor level, from the lowest speed to the highest

dB

How to read these figures. Each dot is a published value for the console, in dB(A): a lower figure means a quieter unit. A console sits near ear level when you are seated or lying down; the lowest speed often matters more than the highest in a bedroom.

Why this is not a ranking. Each manufacturer measures under its own conditions; the values describe each unit, not one against the others.

Values from the AirGreen product pages, based on the manufacturers.

In Longueuil

Three things to look at in your home

The room, not the house

A 12,000 BTU console heats and cools the room it is installed in and a little around it. For a whole house, several units or another type of system are needed.

The exterior wall

Under a window, the wall is often an exterior wall: the run for pipes and drain is short. On an interior wall the route gets longer; compare it with the maximum lengths in the table (66 to 82 ft).

South Shore cold

The normals and design temperature used here come from the Montréal-Trudeau station, across the river. The −23.1 °C design temperature is what heating is sized for; that is where the deep-cold table matters.

Questions

Frequently asked questions

Which one should I pick for a Longueuil home?

None of the three is singled out here. All three consoles are sold as 12,000 BTU units, but their certified values differ with temperature. What decides in your home is how much heat the room loses in the cold, the height under the window, the line set route to the outdoor unit and the noise you can accept.

Why are Trane and Bosch no longer in this article?

AirGreen sells no floor console from either brand. Rather than compare units we can neither document nor install, the page compares the three 12,000 BTU consoles with A2L refrigerant that AirGreen sells, shown in alphabetical order.

Why does the SAMSUNG show 10,200 BTU/h in cooling?

That is the certified rated capacity at 35 °C in NEEP record 406917; the same combination is certified at 13,000 BTU/h rated heating at 8.3 °C and can reach 14,000 BTU/h in cooling. The "12,000" trade name does not replace the certified value.

Can a console replace an electric baseboard under the window?

It often goes in the same spot, low on the wall, but the height available under the sill, the depth into the room and the route for piping and drain are checked on site. The baseboard can stay as backup below the heat pump's last published point.

Are these consoles eligible for LogisVert?

Hydro-Québec keeps the list of eligible units and changes it over the years. Before you sign, look up the AHRI certificate number of the console you pick on that list; we announce no amount here.

How can I redo our checks?

Each NEEP record is online under its number (388975, 387306, 406917). The Sources section also lists the Lennox submittal and the AirGreen product pages used for dimensions, piping and sound.

All three consoles are on the AirGreen site.

Free estimate visit in Longueuil, Montréal, Laval, the North Shore and the South Shore. Quote within 24 hours.

Sources

Documents consulted

NEEP, record 388975GREE CON12HP230V1R32AH + VIR12HP230V1R32AO, AHRI 215415566. Checked Nov. 17, 2026. NEEP, record 387306MIDEA MFAHU-H12B-2A + MO1HS-H12B-2A, AHRI 215471433. Checked Nov. 17, 2026. NEEP, record 406917SAMSUNG AC012DNJDCG + AC012DXSCCG, AHRI 216441749. Checked Nov. 17, 2026. Lennox, MMLD012S6S-1P / MFMD012S6-1P submittal496404, January 2025: 10,200 / 13,000 BTU/h, SEER2 21, EER2 12.2, HSPF2 9.5.
AirGreen product pagesDimensions, weight, piping, airflow, sound levels, dehumidification and Wi-Fi for the three models, based on the manufacturers' documents.
Environment and Climate Change Canada1991-2020 normals, Montréal-Trudeau: January mean −9.2 °C, mean daily low −13.5 °C.
NRCan, HOT2000 climate mapMontréal Intl, design temperature −23.1 °C, 4,167 degree-days.
IPCC, Fourth Assessment Report100-year global warming potential: R-32 675, R-454B 466.