AirGreenOuellet
OUELLET · THERMOSTATS FROM 24 TO 347 VThe Ouellet space at AirGreenThe Ouellet thermostats we sell, loads checked in Ouellet’s spec sheets, installed by AirGreen in Montréal, Laval, Longueuil, the South Shore and the North Shore.
The Ouellet warranty
Mon–Thu 8 a.m.–6 p.m. · Fri 8 a.m.–4 p.m.
Ouellet · Thermostats · Updated October 20, 2026

Ouellet thermostats: start with the voltage of your heating

Ouellet has made heating in L’Islet, Québec, since 1960, and electric baseboards since 1976. Its thermostats run from 24 V to 347 V: baseboards and convectors, heated floors, Zigbee and commercial. Pick your voltage and the page shows the models that fit it, with their maximum load.

What voltage feeds your heating?

Check the label on the heater or the breaker. Maximum loads from Ouellet’s spec sheets.

Baseboards, convectors and heated floors.

Ouellet OCEBMH-TH-DBLpart, OCE convectors

The HP6000ZB-GE has no voltage to pick: it is powered by the heat pump’s board.

1960the company starts in L’Islet
24–347 Vvoltages covered by the lineup
3 yearsthermostat warranty (Ouellet sheets)
15 sproportional cycle for convectors
AirGreen × OUELLETSold and installed by AirGreenFrom 24 V to 347 VUp to 5,000 W at 347 VBaseboards · floors · Zigbee · commercialHeating maker in L’Islet since 1960Montréal · Laval · Longueuil · South Shore · North Shore
01 · The lineup

Six families from one heating maker

Every Ouellet product AirGreen sells, grouped by use. Each model links to its product page.

Ouellet OTH4000-ABaseboards and convectors

Baseboards and convectors

  • 3,000 W (OTH3000) or 4,000 W (OTH4000) at 240 V
  • A: non-programmable · P: up to 4 periods a day
  • 15 s cycle (convector) or 10 min (fan-forced)
Ouellet OTH4000-ZBZigbee

Zigbee and wall heat pump

  • OTH4000-ZB: 4,000 W at 240 V, on Hilo’s list
  • HP6000ZB-GE: ductless heat pump interface
  • GT130 gateway and Neviweb app
Ouellet OTH3600-GA-ZBHeated floor

Heated floor

  • 15 A at 120/208/240 V, double-pole 4-wire
  • Class A 5 mA GFCI, 15 ft sensor included
  • Air mode or floor mode
Ouellet OTH24-AFRLow voltage 24 V

Low voltage 24 V

  • 24 V, 2 outputs (main and backup)
  • AFR programmable 7-day or 5/2 · V2 non-programmable
  • Heating only, through a relay
Ouellet OTH5007Commercial 347 V

Commercial 277/347 V

  • 4,000 W at 277 V, 5,000 W at 347 V
  • Minimum 346 W at 277 V, 434 W at 347 V
  • No heater equipped with a transformer
Ouellet OCEBMH-TH-DBLOCE part

OCE convector part

  • Code listed for the OCE convector series
  • OCE convectors from 500 to 3,000 W, 240/208 V
  • Fit confirmed on quotation
02 · Load check

How many heaters on one thermostat?

Add up the wattage of your heaters. The tool checks the current against the limits Ouellet publishes: 1.25 A minimum (no minimum published for the OTH3600-GA-ZB), and 12.5 A (OTH3000), 16.7 A (OTH4000), 14.4 A (OTH5007) or 15 A (OTH3600-GA-ZB) maximum.

Type of heating
Voltage
  • W
  • W

Indicative only: current = wattage ÷ voltage. Maximum and minimum loads from Ouellet’s spec sheets (OTH3000, OTH4000, OTH4000-ZB, OTH5007, OTH3600-GA-ZB).

Total on one thermostat

2,500 W
that is 10.4 A at 240 V
83% of the 3,000 W maximum.
63% of the 4,000 W maximum.

Smallest model that fits: OTH3000.

The OTH4000-ZB has the same load as the OTH4000, for resistive loads only (Ouellet guide).

AirGreen × OUELLET

Ouellet’s thermostat, AirGreen’s installation.

Ouellet makes the heating and publishes each thermostat’s limits. AirGreen does the math in your home, picks the right model with you and installs it.

Ouellet

What Ouellet brings

  • A heating maker since 1960In L’Islet, on the South Shore east of Québec City: baseboards, convectors and their thermostats.
  • Published loadsEach thermostat’s maximum load, by voltage, in its spec sheets.
  • From 24 V to 347 VLow voltage, residential, Zigbee and commercial in one lineup.
  • 3 years against defectsPer Ouellet’s thermostat sheets.
AirGreen

What AirGreen brings

  • Sold and installed by AirGreenIn Montréal, Laval, Longueuil, the South Shore and the North Shore.
  • Free in-home estimateWe look at your heaters, their voltage and their watts on site.
  • Price on quotationFor the thermostat and its installation.
  • RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16.

The result: the right Ouellet thermostat for your voltage and your watts, chosen with you and installed by AirGreen.

03 · OCE convectors

Your OCE convector keeps its 5-year warranty on two conditions

Ouellet states that the OCE’s 5-year warranty is valid only if the heater is controlled by a proportional pulsing electronic thermostat with a cycle of 15 seconds maximum, and the junction box is fixed to the wall with the supplied anchor.

1. The height of your convector
3. What controls it today

Your convector

OCEM1500
followed by -TH, -OTH or -T600 depending on the version · 1,500 W at 240 V · 1,125 W at 208 V
Meets the conditionThe OTH3000 and OTH4000 sheets describe a proportional pulsing electronic thermostat, with a 15 s cycle for convectors.

Second condition, in every case: junction box fixed to the wall with the supplied anchor. Ouellet: 1-800-463-7043.

A part to replace on an OCE? The code OCEBMH-TH-DBL appears in Ouellet’s parts selector for the OCE series, without a description. Ouellet ties it to no other heater family. What it replaces and whether it fits your convector are confirmed on quotation, from the rating plate. See the OCEBMH-TH-DBL part
04 · Zigbee

Baseboards, floor and wall heat pump in one app

Ouellet’s three Zigbee products go through the GT130 gateway and the Neviweb app. Tell the tool what you want to connect: the list shows what you need, from Ouellet’s sheets and Hilo’s list.

OTH4000-ZBBaseboards and convectors, 4,000 W at 240 V1
OTH3600-GA-ZBHeated floor, 15 A0
HP6000ZB-GEDuctless heat pump interface0

Ouellet publishes no maximum number of devices per gateway in the documents we read.

What you need

1
Zigbee device
  1. GT130 gateway: required, not included (Ouellet).
  2. Internet: required for remote access.
  3. Neviweb app: scheduling is done there.
  4. Hilo: the OTH4000ZB is on Hilo’s list, connected to a Sinopé GT130 gateway. Reward under Hilo’s terms.
  5. Older GT models (OTH4000-GT…): not compatible with these products, but run from the same app (Ouellet).
05 · Heated floor

OTH3600-GA-ZB: air or floor, your choice

Double-pole, 4-wire thermostat, 15 A at 120/208/240 V, with a class A 5 mA ground-fault circuit interrupter (GFCI) and a 15 ft floor sensor included.

Diagram: wall thermostat, floor sensor and room air 21° Air 15 ft sensor
A mode: room airThe thermostat controls the air temperature and can cap the floor temperature.
  • Setpoint range5 to 36 °C (floor and air)
  • SchedulingNeviweb app only
  • Auxiliary outputTR1310 module or low-voltage relay
06 · 24 V and 347 V

Low voltage and commercial: both ends of the lineup

The OTH24 models control heating through a 24 V relay. The OTH5007 wires straight into 277 or 347 V.

OTH24-AFR or OTH24-V2

 OTH24-AFROTH24-V2
Scheduling7-day or 5/2Non-programmable
Outputs2 outputs of 1 A (main and backup)2 outputs (main 1 A)
Wires3 minimum3 minimum (C, W1, R, W2, S1, S2)
Setpoint range5–36 °C5–36 °C
Floor sensorExternal, see the guideExternal 10K or 12K, not included
Heating onlyOuellet’s documents list baseboards (through a relay), convectors, floors, boilers and pumps. They mention neither heat pumps nor cooling.
Commercial 347 V

OTH5007

  • 277 V4,000 W max · 346 W min
  • 347 V5,000 W max · 434 W min
  • Current14.4 A max · 1.25 A min
Check before buyingOuellet: “not compatible with a heater equipped with a transformer”.

For commercial, institutional and industrial use, according to Ouellet. See the OTH5007

07 · Rebates and rules

What really applies to an Ouellet thermostat

Checked on October 20, 2026 on each program’s and regulation’s own site.

  • LogisVertHydro-Québec · guide v1.10, Sept. 15, 2026No

    The guide mentions no thermostat.

  • HiloHydro-Québec · compatible device listOTH4000-ZB

    Hilo lists the “OTH4000ZB” among compatible Sinopé devices, connected through a Sinopé GT130 gateway (not the Hilo hub). The reward and its terms are Hilo’s. The OTH3600-GA-ZB and the HP6000ZB-GE are not listed.

  • ENERGY STARThermostat specification v1.0No

    The specification excludes line-voltage thermostats. No Ouellet product in the certified list (checked October 20, 2026).

  • ÉnergirSmart thermostatsNo

    For natural gas central heating only.

  • Canada Greener Homes GrantGovernment of CanadaClosed

    Requests accepted until September 30, 2025.

  • Québec regulationCQLR c. N-1.01, r. 1Rule

    Thermostats from 120 to 240 V for resistive loads: tested to the CSA C828 standard. Heated floors excluded. Covers the OTH3000, OTH4000 and OTH4000-ZB.

  • Federal regulationSOR/2025-110Rule

    Wall thermostats from 120 to 240 V for baseboards, convectors and floors made since July 1, 2026: CSA C828-19. The Ouellet sheets we read cite CSA-C828-13.

  • 24 V and 347 VOTH24-AFR, OTH24-V2, OTH5007Out of scope

    Both regulations cover thermostats from 120 to 240 V.

AirGreen × OUELLETSold and installed by AirGreenFrom 24 V to 347 VUp to 5,000 W at 347 VBaseboards · floors · Zigbee · commercialHeating maker in L’Islet since 1960Montréal · Laval · Longueuil · South Shore · North Shore
08 · Warranty

3 years on the thermostats, replaced if one fails

The terms below are Ouellet’s. The 30-day registration on Ouellet’s warranty page is for its heat pumps, not its thermostats. Transferability is not stated.

3 years

Against defects

Every Ouellet thermostat sheet in the lineup (OTH3000, OTH4000, OTH5007, OTH4000-ZB, OTH3600-GA-ZB, OTH24) and the HP6000ZB-GE.

Replacement

What Ouellet covers

According to the guides we read, Ouellet replaces the defective product on proof of purchase. Installation is not covered.

5 years

OCE convector

Provided it runs on a proportional electronic thermostat with a 15 s cycle maximum and a junction box anchored to the wall (section 03).

Not stated

OCEBMH-TH-DBL part

No warranty published for the part. Ouellet’s general policy is at least 1 year, by replacement.

Ouellet warranty service: 1-800-463-7043.

09 · FAQ

Common questions about Ouellet thermostats

Type a word (208 V, Hilo, floor, warranty) to filter the answers.

14 questions
Which Ouellet thermostat for a 2,000 W baseboard at 240 V?
An OTH3000 is enough: it takes up to 3,000 W at 240 V. The OTH4000 goes up to 4,000 W if you plan to add a heater on the same thermostat.
Can I connect several baseboards to one thermostat?
Yes, as long as the total current stays between 1.25 A and the model’s maximum: 12.5 A for the OTH3000, 16.7 A for the OTH4000. The load check (section 02) adds it up for you.
My building runs on 208 V. What changes?
Maximums drop: 2,600 W for the OTH3000 and 3,465 W for the OTH4000. A convector also gives less heat: a 1,500 W OCE at 240 V gives 1,125 W at 208 V, per Ouellet’s sheet.
What is the difference between the OTH4000-A and the OTH4000P-A?
Same load (4,000 W at 240 V). The P is programmable, with up to 4 periods a day. The A is not.
Does the OTH4000-ZB work with Hilo?
Hilo’s list includes the “OTH4000ZB”, connected through a Sinopé GT130 gateway rather than the Hilo hub. The reward and its terms are set by Hilo, a Hydro-Québec subsidiary.
Do the Zigbee models need a gateway?
Yes. Ouellet requires the GT130 gateway (not included) for the OTH4000-ZB, the OTH3600-GA-ZB and the HP6000ZB-GE. Scheduling is done only in the Neviweb app.
Does the HP6000ZB-GE work with my wall heat pump?
Ouellet describes it as an interface for ACD ductless heat pumps, available with selected models only. It plugs into the RJ45 port on the indoor unit’s board. Its advanced functions need the GT130 gateway, Internet and an OTH4000-ZB. Fit with your unit is confirmed on quotation.
Can an OTH24 control a heat pump or air conditioning?
Ouellet’s documents do not say so. They describe two heating outputs (main and backup) through a 24 V relay.
Can the floor thermostat heat by room air?
Yes. In A mode the OTH3600-GA-ZB controls the air and can cap the floor temperature. In F mode it controls the floor with the sensor and can cap the air.
Does an Ouellet thermostat qualify for LogisVert?
No. The LogisVert guide v1.10 of September 15, 2026 mentions no thermostat.
How long is the warranty?
Three years against defects, per Ouellet’s sheets. According to the guides, Ouellet replaces the product on proof of purchase. Installation is not covered.
Does the OCEBMH-TH-DBL part fit any Ouellet baseboard?
Ouellet lists it only among the parts of the OCE convector series. Nothing points to any other heater. Fit is confirmed on quotation.
Are Ouellet thermostats made in Québec?
Ouellet has been based in L’Islet, Québec, since 1960. The company says it has assembled some products at its plant in China since 2005 and does not say where its thermostats are made.
Can AirGreen install an Ouellet thermostat?
Yes. AirGreen holds RBQ licence 5645-9605-01, including subclass 16 (electrical). Price on quotation.

No answer matches. Write to us: the quotation is free.

AirGreen

Choosing or replacing an Ouellet thermostat?

Tell us the voltage, the wattage of your heaters and the room. Price on quotation, and the quotation is free.

  • Showroom
    1370, rue Joliot-Curie, local 712, Boucherville
  • Hours
    Mon–Thu 8 a.m.–6 p.m. · Fri 8 a.m.–4 p.m.
  • RBQ licence
    5645-9605-01 · subclasses 15.8, 15.10, 16
  • All thermostats
    See the Thermostats collection
Price on quotationThe quotation is free.

AirGreen × OUELLET

Ouellet elsewhere on our site

The product count updates by itself.

The Ouellet shop

All our Ouellet products, right below.

Baseboards and convectors, Zigbee, heated floors, 24 V, 347 V and the OCE part: open each model’s product page. Price and availability on quotation.