HITACHI airHome 400 and HITACHI airHome 600, figure by figure
HITACHI's first two airHome wall series, in the same 12,000 BTU size. Here is what their AHRI certificates and HITACHI's brochures publish: efficiency, heating in deep cold, sound, installation and estimated electricity cost in Montréal.
HITACHI
airHome 400
RAK-DJ12RHAA / RAC-DJ12WHAA · AHRI 216759656HITACHI brochure, January 2025. Wi-Fi available as an option, with an adapter sold separately.
See the product page
HITACHI
airHome 600
RAK-GJ12PHAA / RAC-GJ12WHAA · AHRI 215413019HITACHI brochure, December 2024. Wi-Fi adapter included and heated base pan as standard, according to the brochure.
See the product pageWhat the electricity costs, in dollars, winter and summer
AirGreen estimate for the same 12,000 BTU/h zone in Montréal, at Hydro-Québec Rate D, taxes included. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the point of reference.
The winter gap comes from HSPF2 Region V: 7.0 for the airHome 400 and 9.0 for the airHome 600. In summer, the SEER2 values are close (19.5 and 20), and so is the gap.
How this amount is calculated
- Heat needed over the winter. A zone whose heat loss reaches 12,000 BTU/h ( kW) at −23.1 °C, Montréal’s design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for round-the-clock heating, all winter. Heating degree-days (18 °C base) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours a day (the “Heating” slider), the heat is reduced in the same proportion, for the heat pump and the baseboards alike: this is a simplification that ignores the recovery after a temperature setback.
- Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup expected when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
- Electricity for cooling. 12,000 BTU/h ÷ SEER2 × hours a day × 60 days ÷ 1,000: the method of Hydro-Québec’s air conditioning calculator, with the seasonal SEER2 efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day long: that is a maximum, since a variable-speed unit slows down once the room is at the right temperature.
- Price. Hydro-Québec Rate D in effect on April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ beyond that; the average price, 9.104¢, is the one offered by Hydro-Québec’s calculators. GST and QST included. The system access charge, the same with or without a heat pump, is not counted.
AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The actual bill depends on the house, the insulation, the settings and how it is used; this amount is not a promise.
400, 600 and 800: the certificates side by side
The steps follow HITACHI's numbering, not a ranking. This page compares the 400 and the 600; the 800, dotted, has its own page with the 600. Choose a measure: each bar shows the value on the series' AHRI certificate, in the 12,000 BTU size.
Below −15 °C: what each series publishes, point by point
Both certificates give a capacity at −15 °C. Further down, the airHome 400 certificate stops at −20 °C, the airHome 600's at −25 °C. The 600 brochure adds a maximum capacity at −20 °C. No figure is calculated between two points.
What HITACHI writes for each series
HITACHI often gives different names to similar functions from one series to the next: GoodSleep and SleepSense, Eco and Smart Eco. Each card puts both names side by side, as printed; “not named” means the brochure does not mention it.
The coil frosts then defrosts to rinse itself. The 600 brochure calls it FrostWash 3.0.
400: SPX-WFG03 adapter sold separately, Cloud GO app. 600: airCloud Go app, Alexa and Google Home voice control.
The 600 brochure lists it as standard; the NEEP record gives 150 W. The 400's NEEP record leaves this field blank.
With a stainless steel pre-filter, in both brochures.
After shutdown, the 400 blows air and heats the coil to 50 °C for about 60 minutes, according to its brochure.
Both brochures name an optional HITACHI wall control.
Named in both brochures; no figures are attached to it here.
A night setting named in each brochure, under a different name.
Blue condenser treatment, named in both brochures.
The 600 brochure ties it to the heated condensate pan.
A mode that keeps the home from freezing during an absence.
The 400 brochure mentions a snow hood available as an accessory for the outdoor unit.
Five speeds each, published by HITACHI
Both brochures give the indoor unit's heating sound for five fan speeds, from the quietest to the loudest. For the outdoor unit, at high speed: 51 dB(A) for the 400 and 52 dB(A) for the 600.
Indoor unit, heating
One value per speed, according to each brochure
How to read these figures. Five dots per line, one per fan speed, from silent mode to maximum speed. Both series start at 29 dB(A) and end at 46 dB(A); only the fourth speed differs, by one decibel (44 and 43). The 400 brochure states that 29 dB(A) is a sound pressure, in silent mode.
Why this is not a ranking. Same manufacturer, same table format, but the brochures do not give the measuring distance. The values can be read side by side; they do not describe the sound in a particular room.
Measurements taken by each manufacturer with its own method; here, the same manufacturer for both, distance not stated.
Same piping limits, two unit sizes
Both brochures give 82 ft of line set at most, 49.2 ft of height difference and 1/4 and 3/8 in lines. The differences are in size: the 600 indoor unit is almost 7 in wider, and its outdoor unit is larger and heavier.
The indoor units, at the same scale




Widths to scale from the HITACHI brochures. The side clearances required by the installation manual come on top and are not counted here. HITACHI photos, cut out.
The outdoor units, at the same scale


HITACHI photos, cut out and scaled to the published width; the photo includes the sides and feet, hence a possible slight difference with the dimension.
| Line | airHome 400 | airHome 600 |
|---|---|---|
| Line set | ||
| Maximum piping length | 82 ft25 m | 82 ft25 m |
| Maximum height difference | 49.2 ft15 m | 49.2 ft15 m |
| Pre-charged length | Not published by the manufacturer in the brochure. | Not published by the manufacturer in the brochure. |
| Liquid – gas diameters | 1/4 – 3/8 in | 1/4 – 3/8 in |
| Factory R-32 refrigerant charge | 1.76 lb (0.80 kg)maximum charge 1.98 lb | 2.45 lb (1.11 kg)maximum charge 2.67 lb |
| Dimensions and weight | ||
| Outdoor unit W × H × D, weight | 29.53 × 22.44 × 11.02 in, 75.0 lb | 33.46 × 25.59 × 11.73 in, 91.0 lb |
| Indoor unit, weight | 18.74 lb30.71 × 11.02 × 8.74 in | 24.3 lb37.40 × 11.57 × 9.06 in |
| Clearances around the outdoor unit | Not published by the manufacturer in the brochure; see the installation manual. | Not published by the manufacturer in the brochure; see the installation manual. |
| Electrical and operation | ||
| Electrical protection | 208-230 V, MCA 9 A, MOP 15 A | 208-230 V, MCA 14 A, MOP 15 A |
| Dehumidification | 1.65 L/h | 1.6 L/h |
| Indoor fan airflow, heating | 140 to 280 CFM | 154 to 457 CFM |
| Advertised heating / cooling range | −20.5 to 24 °C / −18 to 46 °C | −25 to 24 °C / −18 to 46 °C |
Sources: HITACHI airHome 400 brochure (Johnson Controls-Hitachi, January 2025_CA) and HITACHI airHome 600 brochure (December 2024_CA). The maximum charge is printed; the gap from the factory charge is not a per-foot rate.
Questions about the airHome 400 and the airHome 600
Where do the 400 and 600 certificates part ways?
Mainly in heating. HSPF2 Region V: 7.0 and 9.0. Certified maximum capacity: 13,700 and 18,000 BTU/h at 8.3 °C, 12,000 and 16,800 at −8.3 °C, 10,250 and 14,500 at −15 °C. The coldest test point is −20 °C for the 400 and −25 °C for the 600. In cooling, the SEER2 values are close: 19.5 and 20.
Why is the winter estimate so different?
The method uses the certificate's HSPF2 Region V: 7.0 for the 400, 9.0 for the 600. For the same heat to supply, the estimated electricity is therefore lower for the 600. The sliders show how the gap changes with the hours and the price tier.
What is published for the airHome 400 below −20 °C?
The certificate stops at −4 °F (−20 °C), with 8,000 BTU/h. The January 2025 brochure advertises a heating range down to −5 °F (−20.5 °C). A HITACHI submittal sheet from July 2024 prints a range down to −13 °F, with capacities that do not match the 12,000 BTU size; the page follows the more recent brochure. No document consulted gives a colder capacity.
Is Wi-Fi included?
According to the brochures, the Wi-Fi adapter is included with the airHome 600 and available as an option for the airHome 400 (SPX-WFG03 adapter sold separately).
Why does NEEP show two records for each model?
For each certificate, NEEP returns two records. For the 600 (484778 and 437513), they are identical. For the 400, record 437503 gives inconsistent minimum and maximum COPs (for example 9.48 at 8.3 °C); the page follows record 484704, whose values are consistent with the brochure.
Are both listed as cold-climate heat pumps?
The ENERGY STAR directory lists both combinations with the cold-climate mention, since May 6, 2026, for the United States market. The NEEP records also show ENERGY STAR and cold climate for both.
And the airHome 800?
It has its own page with the airHome 600. In “The range” section, it is shown dotted with the values on its certificate (AHRI 215911631) to place the three series.
What AHRI certifies for the 400 and the 600
| Measure | airHome 400 | airHome 600 |
|---|---|---|
| Seasonal efficiency | ||
| SEER2 | 19.5 | 20 |
| EER2 | 12 | 13 |
| HSPF2 Region IV | 9.2 | 11.1 |
| HSPF2 Region V | 7.0 | 9.0 |
| Rated capacity at 35 °C (95 °F), cooling | 12,000 BTU/h | 12,000 BTU/h |
| Certified heating | ||
| Capacity at 8.3 °C (47 °F): min. / rated / max. | 5,500 / 12,000 / 13,700 BTU/h | 5,500 / 12,000 / 18,000 BTU/h |
| COP at 8.3 °C: at min., rated, max. | 2.78 / 3.20 / 3.37 | 1.61 / 3.78 / 2.40 |
| Capacity at −8.3 °C (17 °F): min. / rated / max. | 4,000 / 8,400 / 12,000 BTU/h | 3,500 / 9,400 / 16,800 BTU/h |
| COP at −8.3 °C: at min., rated, max. | 2.02 / 2.59 / 2.25 | 1.28 / 2.75 / 2.46 |
| Capacity at −15 °C (5 °F): min. / rated / max. | 3,500 / 9,200 / 10,250 BTU/h | 3,200 / 11,000 / 14,500 BTU/h |
| COP at −15 °C: at min., rated, max. | 2.05 / 2.12 / 2.10 | 1.04 / 2.50 / 1.77 |
| Coldest point on the certificate (different temperatures) | ||
| Test temperature | −20 °C (−4 °F) | −25 °C (−13 °F) |
| Capacity min. / max. | 2,600 / 8,000 BTU/h | 2,800 / 8,800 BTU/h |
| COP at min. / max. capacity | 1.52 / 1.91 | 1.03 / 1.52 |
| Certification | ||
| AHRI certificate · NEEP record | 216759656 · record 484704 | 215413019 · record 484778 |
| ENERGY STAR, directory (cold climate) | Yes, listed cold climate, United States, May 6, 2026 | Yes, listed cold climate, United States, May 6, 2026 |
| Refrigerant | R-32, GWP 675 (IPCC AR4), class A2L (ASHRAE 34) | R-32, GWP 675 (IPCC AR4), class A2L (ASHRAE 34) |
“higher” marks the higher value of the same measure, under the same conditions. It is not a recommendation.
Both are on the AirGreen site.
AirGreen offers HITACHI's airHome 400 and airHome 600. To find out which of the two suits your room and your wall, or for a quote, call or write to us.