HITACHI airHome 400 and HITACHI airHome 600, 12,000 BTU

Comparison · Wall heat pump · 12,000 BTU

HITACHI airHome 400 and HITACHI airHome 600, figure by figure

HITACHI's first two airHome wall series, in the same 12,000 BTU size. Here is what their AHRI certificates and HITACHI's brochures publish: efficiency, heating in deep cold, sound, installation and estimated electricity cost in Montréal.

HITACHI airHome 400 wall heat pump, indoor unit, outdoor unit and remote HITACHI

airHome 400

RAK-DJ12RHAA / RAC-DJ12WHAA · AHRI 216759656

HITACHI brochure, January 2025. Wi-Fi available as an option, with an adapter sold separately.

See the product page
HITACHI airHome 600 wall heat pump, indoor unit, outdoor unit and remote HITACHI

airHome 600

RAK-GJ12PHAA / RAC-GJ12WHAA · AHRI 215413019

HITACHI brochure, December 2024. Wi-Fi adapter included and heated base pan as standard, according to the brochure.

See the product page
SEER2, seasonal cooling efficiency
19.5/20
HSPF2 Region V, seasonal heating efficiency
7.0/9.0
Certified maximum capacity at −15 °C, BTU/h
10,250/14,500
Coldest test point on the certificate
−20 °C/−25 °C
airHome 400 HITACHIairHome 600 HITACHI
Estimated running cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for the same 12,000 BTU/h zone in Montréal, at Hydro-Québec Rate D, taxes included. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the point of reference.

The winter gap comes from HSPF2 Region V: 7.0 for the airHome 400 and 9.0 for the airHome 600. In summer, the SEER2 values are close (19.5 and 20), and so is the gap.

How this amount is calculated
  1. Heat needed over the winter. A zone whose heat loss reaches 12,000 BTU/h ( kW) at −23.1 °C, Montréal’s design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for round-the-clock heating, all winter. Heating degree-days (18 °C base) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours a day (the “Heating” slider), the heat is reduced in the same proportion, for the heat pump and the baseboards alike: this is a simplification that ignores the recovery after a temperature setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup expected when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 12,000 BTU/h ÷ SEER2 × hours a day × 60 days ÷ 1,000: the method of Hydro-Québec’s air conditioning calculator, with the seasonal SEER2 efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day long: that is a maximum, since a variable-speed unit slows down once the room is at the right temperature.
  4. Price. Hydro-Québec Rate D in effect on April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ beyond that; the average price, 9.104¢, is the one offered by Hydro-Québec’s calculators. GST and QST included. The system access charge, the same with or without a heat pump, is not counted.

AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The actual bill depends on the house, the insulation, the settings and how it is used; this amount is not a promise.

The airHome range in three steps

400, 600 and 800: the certificates side by side

The steps follow HITACHI's numbering, not a ranking. This page compares the 400 and the 600; the 800, dotted, has its own page with the 600. Choose a measure: each bar shows the value on the series' AHRI certificate, in the 12,000 BTU size.

See the airHome 600 and airHome 800 page
Deep cold

Below −15 °C: what each series publishes, point by point

Both certificates give a capacity at −15 °C. Further down, the airHome 400 certificate stops at −20 °C, the airHome 600's at −25 °C. The 600 brochure adds a maximum capacity at −20 °C. No figure is calculated between two points.

At −20 °C, two different sources. For the airHome 400, 8,000 BTU/h comes from the AHRI certificate (−4 °F). For the airHome 600, 11,200 BTU/h comes from the HITACHI brochure (“max. heating capacity” at −4 °F); its certificate has no point at that temperature. The two figures sit at the same place on the scale, but not from the same source.
Named functions

What HITACHI writes for each series

HITACHI often gives different names to similar functions from one series to the next: GoodSleep and SleepSense, Eco and Smart Eco. Each card puts both names side by side, as printed; “not named” means the brochure does not mention it.

FrostWash cleaning
Indoor onlyairHome 400Indoor and outdoorairHome 600

The coil frosts then defrosts to rinse itself. The 600 brochure calls it FrostWash 3.0.

Wi-Fi and app
OptionalairHome 400Adapter includedairHome 600

400: SPX-WFG03 adapter sold separately, Cloud GO app. 600: airCloud Go app, Alexa and Google Home voice control.

Heated base pan
Not named in the brochureairHome 400Standard, 150 WairHome 600

The 600 brochure lists it as standard; the NEEP record gives 150 W. The 400's NEEP record leaves this field blank.

PM2.5 activated carbon filter
NamedairHome 400NamedairHome 600

With a stainless steel pre-filter, in both brochures.

Mold protection
Mold GuardairHome 400ProtectorairHome 600

After shutdown, the 400 blows air and heats the coil to 50 °C for about 60 minutes, according to its brochure.

Optional wall thermostat
Point Room H700airHome 400airPoint RoomairHome 600

Both brochures name an optional HITACHI wall control.

Economy mode
EcoairHome 400Smart EcoairHome 600

Named in both brochures; no figures are attached to it here.

Sleep mode
GoodSleepairHome 400SleepSenseairHome 600

A night setting named in each brochure, under a different name.

Anti-corrosion protection
Blue finsairHome 400Blue coatingairHome 600

Blue condenser treatment, named in both brochures.

Adaptive defrost
Not named in the brochureairHome 400NamedairHome 600

The 600 brochure ties it to the heated condensate pan.

Leave Home freeze protection mode
NamedairHome 400Not named in the brochureairHome 600

A mode that keeps the home from freezing during an absence.

Snow hood, accessory
AvailableairHome 400Not named in the brochureairHome 600

The 400 brochure mentions a snow hood available as an accessory for the outdoor unit.

Sound

Five speeds each, published by HITACHI

Both brochures give the indoor unit's heating sound for five fan speeds, from the quietest to the loudest. For the outdoor unit, at high speed: 51 dB(A) for the 400 and 52 dB(A) for the 600.

Indoor unit, heating

One value per speed, according to each brochure

dB(A)

How to read these figures. Five dots per line, one per fan speed, from silent mode to maximum speed. Both series start at 29 dB(A) and end at 46 dB(A); only the fourth speed differs, by one decibel (44 and 43). The 400 brochure states that 29 dB(A) is a sound pressure, in silent mode.

Why this is not a ranking. Same manufacturer, same table format, but the brochures do not give the measuring distance. The values can be read side by side; they do not describe the sound in a particular room.

Measurements taken by each manufacturer with its own method; here, the same manufacturer for both, distance not stated.

Installation

Same piping limits, two unit sizes

Both brochures give 82 ft of line set at most, 49.2 ft of height difference and 1/4 and 3/8 in lines. The differences are in size: the 600 indoor unit is almost 7 in wider, and its outdoor unit is larger and heavier.

The indoor units, at the same scale

airHome 40030.71 × 11.02 × 8.74 in
HITACHI airHome 400 indoor unit
30.71 in
airHome 60037.40 × 11.57 × 9.06 in
HITACHI airHome 600 indoor unit
37.40 in
36 in
airHome 400 within the chosen width

airHome 600 within the chosen width

048 in

Widths to scale from the HITACHI brochures. The side clearances required by the installation manual come on top and are not counted here. HITACHI photos, cut out.

The outdoor units, at the same scale

airHome 40029.53 × 22.44 × 11.02 in, 75.0 lb
HITACHI airHome 400 outdoor unit
29.53 in
airHome 60033.46 × 25.59 × 11.73 in, 91.0 lb
HITACHI airHome 600 outdoor unit
33.46 in

HITACHI photos, cut out and scaled to the published width; the photo includes the sides and feet, hence a possible slight difference with the dimension.

LineairHome 400airHome 600
Line set
Maximum piping length82 ft25 m82 ft25 m
Maximum height difference49.2 ft15 m49.2 ft15 m
Pre-charged lengthNot published by the manufacturer in the brochure.Not published by the manufacturer in the brochure.
Liquid – gas diameters1/4 – 3/8 in1/4 – 3/8 in
Factory R-32 refrigerant charge1.76 lb (0.80 kg)maximum charge 1.98 lb2.45 lb (1.11 kg)maximum charge 2.67 lb
Dimensions and weight
Outdoor unit W × H × D, weight29.53 × 22.44 × 11.02 in, 75.0 lb33.46 × 25.59 × 11.73 in, 91.0 lb
Indoor unit, weight18.74 lb30.71 × 11.02 × 8.74 in24.3 lb37.40 × 11.57 × 9.06 in
Clearances around the outdoor unitNot published by the manufacturer in the brochure; see the installation manual.Not published by the manufacturer in the brochure; see the installation manual.
Electrical and operation
Electrical protection208-230 V, MCA 9 A, MOP 15 A208-230 V, MCA 14 A, MOP 15 A
Dehumidification1.65 L/h1.6 L/h
Indoor fan airflow, heating140 to 280 CFM154 to 457 CFM
Advertised heating / cooling range−20.5 to 24 °C / −18 to 46 °C−25 to 24 °C / −18 to 46 °C

Sources: HITACHI airHome 400 brochure (Johnson Controls-Hitachi, January 2025_CA) and HITACHI airHome 600 brochure (December 2024_CA). The maximum charge is printed; the gap from the factory charge is not a per-foot rate.

Questions

Questions about the airHome 400 and the airHome 600

Where do the 400 and 600 certificates part ways?

Mainly in heating. HSPF2 Region V: 7.0 and 9.0. Certified maximum capacity: 13,700 and 18,000 BTU/h at 8.3 °C, 12,000 and 16,800 at −8.3 °C, 10,250 and 14,500 at −15 °C. The coldest test point is −20 °C for the 400 and −25 °C for the 600. In cooling, the SEER2 values are close: 19.5 and 20.

Why is the winter estimate so different?

The method uses the certificate's HSPF2 Region V: 7.0 for the 400, 9.0 for the 600. For the same heat to supply, the estimated electricity is therefore lower for the 600. The sliders show how the gap changes with the hours and the price tier.

What is published for the airHome 400 below −20 °C?

The certificate stops at −4 °F (−20 °C), with 8,000 BTU/h. The January 2025 brochure advertises a heating range down to −5 °F (−20.5 °C). A HITACHI submittal sheet from July 2024 prints a range down to −13 °F, with capacities that do not match the 12,000 BTU size; the page follows the more recent brochure. No document consulted gives a colder capacity.

Is Wi-Fi included?

According to the brochures, the Wi-Fi adapter is included with the airHome 600 and available as an option for the airHome 400 (SPX-WFG03 adapter sold separately).

Why does NEEP show two records for each model?

For each certificate, NEEP returns two records. For the 600 (484778 and 437513), they are identical. For the 400, record 437503 gives inconsistent minimum and maximum COPs (for example 9.48 at 8.3 °C); the page follows record 484704, whose values are consistent with the brochure.

Are both listed as cold-climate heat pumps?

The ENERGY STAR directory lists both combinations with the cold-climate mention, since May 6, 2026, for the United States market. The NEEP records also show ENERGY STAR and cold climate for both.

And the airHome 800?

It has its own page with the airHome 600. In “The range” section, it is shown dotted with the values on its certificate (AHRI 215911631) to place the three series.

Certified sheet

What AHRI certifies for the 400 and the 600

MeasureairHome 400airHome 600
Seasonal efficiency
SEER219.520
EER21213
HSPF2 Region IV9.211.1
HSPF2 Region V7.09.0
Rated capacity at 35 °C (95 °F), cooling12,000 BTU/h12,000 BTU/h
Certified heating
Capacity at 8.3 °C (47 °F): min. / rated / max.5,500 / 12,000 / 13,700 BTU/h5,500 / 12,000 / 18,000 BTU/h
COP at 8.3 °C: at min., rated, max.2.78 / 3.20 / 3.371.61 / 3.78 / 2.40
Capacity at −8.3 °C (17 °F): min. / rated / max.4,000 / 8,400 / 12,000 BTU/h3,500 / 9,400 / 16,800 BTU/h
COP at −8.3 °C: at min., rated, max.2.02 / 2.59 / 2.251.28 / 2.75 / 2.46
Capacity at −15 °C (5 °F): min. / rated / max.3,500 / 9,200 / 10,250 BTU/h3,200 / 11,000 / 14,500 BTU/h
COP at −15 °C: at min., rated, max.2.05 / 2.12 / 2.101.04 / 2.50 / 1.77
Coldest point on the certificate (different temperatures)
Test temperature−20 °C (−4 °F)−25 °C (−13 °F)
Capacity min. / max.2,600 / 8,000 BTU/h2,800 / 8,800 BTU/h
COP at min. / max. capacity1.52 / 1.911.03 / 1.52
Certification
AHRI certificate · NEEP record216759656 · record 484704215413019 · record 484778
ENERGY STAR, directory (cold climate)Yes, listed cold climate, United States, May 6, 2026Yes, listed cold climate, United States, May 6, 2026
RefrigerantR-32, GWP 675 (IPCC AR4), class A2L (ASHRAE 34)R-32, GWP 675 (IPCC AR4), class A2L (ASHRAE 34)

“higher” marks the higher value of the same measure, under the same conditions. It is not a recommendation.

Both are on the AirGreen site.

AirGreen offers HITACHI's airHome 400 and airHome 600. To find out which of the two suits your room and your wall, or for a quote, call or write to us.

Sources

Documents consulted

NEEP, record 484704 · AHRI 216759656HITACHI airHome 400, RAK-DJ12RHAA / RAC-DJ12WHAA. ashp.neep.org, consulted November 10, 2026.
NEEP, record 484778 · AHRI 215413019HITACHI airHome 600, RAK-GJ12PHAA / RAC-GJ12WHAA. ashp.neep.org, consulted November 10, 2026.
NEEP, record 484774 · AHRI 215911631HITACHI airHome 800, for “The range” section. Consulted November 10, 2026.
ENERGY STAR directory, heat pumpsdata.energystar.gov, dataset 83eb-xbyy, searches 216759656 and 215413019, consulted November 10, 2026.
HITACHI, airHome 400 brochure (EN)Johnson Controls-Hitachi Air Conditioning, January 2025_CA. Consulted November 10, 2026.
HITACHI, airHome 600 brochure (FR)Johnson Controls-Hitachi Air Conditioning, December 2024_CA. Consulted November 10, 2026.
HITACHI, RAC-DJ12WHAA submittal sheetJuly 2024 revision (rsd.net). Cited only for its heating range, which differs from the brochure.
Hydro-Québec, Electricity RatesApril 1, 2026, Rate D, sec. 2.5. Subject to change.
NRCan, HOT2000 climate mapMontréal Intl station: 4,167 degree-days (18 °C base), design temperature −23.1 °C.