KINGHOME POLARIS R32 and GREE EXTRÊME R32, 18,000 BTU

Home / Comparisons / 18,000 BTU wall-mounted heat pumps

Comparison · Wall-mounted heat pump · 18,000 BTU

KINGHOME POLARIS R32 and GREE EXTRÊME R32 at 18,000 BTU: two certified records, line by line

Two 18,000 BTU wall-mounted units on R-32, both certified down to −30 °C and offered by AirGreen. Their AHRI certificates are distinct, yet very close on several lines. This page overlays them, measure by measure, to show where they meet and where they part.

SEER2 24.5 and 27.5HSPF2 V 8.0 and 8.0Maximum at −15 °C : 16,500 and 18,000 BTU/hMaximum at −30 °C : 11,000 and 10,800 BTU/h
GREE EXTRÊME R32 (AirGreen image)
GREE

EXTRÊME R32 18,000 BTU

GWH18AVEXF-D6DNA1B/I / GWH18AVEXF-D6DNA1B/O · AHRI 215386340

Also sold as GREE AIRY R32, same AHRI certificate.

See the product page
Estimated operating cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for the same 18,000 BTU/h zone in Montréal, at Hydro-Québec’s Rate D, taxes included. Both heat pumps are calculated in exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the reference point.

How this amount is calculated
  1. Heat to deliver over the winter. A zone whose heat loss reaches 18,000 BTU/h ( kW) at −23.1 °C, Montréal’s design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for round-the-clock heating, all winter. Heating degree-days (base 18 °C) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours per day (“Heating” slider), the heat is reduced in the same proportion, for the heat pump as for the baseboards: this simplification does not account for recovery after a temperature setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup expected when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 18,000 BTU/h ÷ SEER2 × hours per day × 60 days ÷ 1,000: the method of Hydro-Québec’s air-conditioning calculator, with the SEER2 seasonal efficiency from the AHRI certificate. The number of hours is a scenario you can set above, from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day long: that is a ceiling, since a variable-speed unit slows down once the room is at temperature.
  4. Price. Hydro-Québec Rate D in effect April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ beyond; the average price, 9.104¢, is the one Hydro-Québec’s calculators use. GST and QST included. Network access charges, the same with or without a heat pump, are not counted.

AirGreen method v1.1, November 9, 2026. An estimate is used to compare units under the same conditions. The actual bill depends on the house, the insulation, the settings and the use; this amount is not a promise.

Two records at 18,000

The two certificates overlaid: only the differences stay lit

On each row, the top bar is the POLARIS R32 and the bottom bar the EXTRÊME R32, on the same scale. When the two certified values are identical, the row dims. The 19 measures come from NEEP records 505227 and 389441.

POLARIS R32 KINGHOME · AHRI 218640147EXTRÊME R32 GREE · AHRI 215386340

Gap in %: difference between the two values ÷ the smaller of the two. The bars on a given row share the same scale; the scale changes from row to row. A gap is not a ranking: depending on the row, the higher value changes sides.

What the overlay shows. Out of 19 certified measures, 3 are identical, including Region V HSPF2 (8.0), and 9 others differ by 5% or less. Three gaps reach 10% or more: SEER2 (24.5 and 27.5), minimum capacity at 8.3 °C (4,400 and 5,000 BTU/h) and COP at −30 °C (1.40 and 1.23). The direction of the gap changes from row to row: at −15 °C, the EXTRÊME R32 has the higher maximum capacity; at −8.3 °C and −30 °C, the POLARIS R32 does.
From minimum to maximum

Each unit's range at 18,000 BTU, at three temperatures

For each temperature, NEEP publishes the lowest certified output, the rated capacity and the maximum. The two ranges overlap almost entirely; the bars show where they separate.

At 8.3 °C outside

POLARIS R324,400 – 22,000 BTU/hrated 18,000 · maximum = 122 % of the size
EXTRÊME R325,000 – 23,000 BTU/hrated 18,600 · maximum = 128 % of the size

At −8.3 °C outside

POLARIS R327,900 – 21,000 BTU/hrated 20,400 · maximum = 117 % of the size
EXTRÊME R328,000 – 20,100 BTU/hrated 19,500 · maximum = 112 % of the size

At −15 °C outside

POLARIS R326,700 – 16,500 BTU/hrated 16,500 · maximum = 92 % of the size
EXTRÊME R326,800 – 18,000 BTU/hrated 18,000 · maximum = 100 % of the size

Same scale for every bar, from 0 to 24,000 BTU/h. Yellow tick: certified rated capacity at that temperature. “% of the size”: certified maximum capacity ÷ 18,000 BTU/h.

At 8.3 °C, the POLARIS R32 goes down to 4,400 BTU/h and the EXTRÊME R32 to 5,000 BTU/h. At −8.3 °C and −15 °C, the two minimums are within 100 BTU/h of each other. At −15 °C, rated and maximum capacity are one and the same for each unit: 16,500 BTU/h for the POLARIS R32, 18,000 BTU/h for the EXTRÊME R32.

Extreme cold

Below −15 °C: every published figure, at its exact temperature

NEEP certifies both units at the same temperatures, down to −30 °C. Each figure is placed at its exact temperature, with its source. Nothing is calculated between two points.

Two common points, and a crossover. Both units are certified at the same temperatures, −15 °C and −30 °C. At −15 °C, the EXTRÊME R32 delivers 18,000 BTU/h at maximum and the POLARIS R32, 16,500. At −30 °C, the order reverses slightly: 11,000 BTU/h for the POLARIS R32 (COP 1.40), 10,800 BTU/h for the EXTRÊME R32 (COP 1.23). The points are not connected: nothing says at what temperature the two curves cross.
What each manufacturer publishes between −15 and −30 °C. The KINGHOME sheet for the POLARIS R32 stops at 5 °F (−15 °C), where it prints the certificate's 16,500 BTU/h; GREE Canada brochure no. 032025 prints no cold-weather capacity. Both state a heating range of −30 to 30 °C. At −20 and −25 °C, the table therefore gives, for each unit, the bracket between its two certified points, with no calculated value.
Documented features

What each document names

KINGHOME POLARIS R32 sheet distributed by AirGreen (undated); GREE Canada EXTRÊME R32 brochure no. 032025; NEEP records for the base pan heater. Each line quotes what the document says. A feature missing from a document is not necessarily missing from the unit.

Extreme cold

POLARIS R32: heating stated down to −30 °C. Outdoor base pan heater: 96 W, on below 1 °C or during defrost (NEEP record).

EXTRÊME R32: heating stated down to −30 °C. Outdoor base pan heater: 96 W, on below 1 °C or during defrost (NEEP record).

Cooling in cold weather

POLARIS R32: down to −29 °C outside.

EXTRÊME R32: down to −29 °C outside.

Modes

POLARIS R32: the sheet names a Turbo mode, ultra-quiet operation and G-AI energy saving.

EXTRÊME R32: “G-AI Learning”.

Controls

POLARIS R32: Wi-Fi and app control; remote model not stated.

EXTRÊME R32: Wi-Fi (app not named); YBE1FB1F remote; XE-71 wired thermostat among the accessories.

Louvers and dehumidification

POLARIS R32: the sheet names 3D airflow control and humidity control; 1.8 L/h.

EXTRÊME R32: 1.8 L/h; louver control is not described in the brochure.

Maintenance and compressor

POLARIS R32: smart cleaning is named; the compressor is listed as triple rotary.

EXTRÊME R32: washable filters; “G10 Inverter”, two-stage variable-speed compressor.

The percentage the KINGHOME sheet attaches to the G-AI feature is not repeated here: no test method comes with it.

Sound

The sound of each at 18,000 BTU, according to its manufacturer

KINGHOME publishes a range for the POLARIS R32, from minimum to maximum. GREE publishes seven levels for the EXTRÊME R32. Neither gives the measurement distance or conditions.

dB(A)

How to read these figures. dB(A) measures a noise level as the ear perceives it: the lower the figure, the quieter the unit. Each dot is a value published by the manufacturer.

Why this is not a ranking. KINGHOME publishes a minimum and a maximum; GREE, seven levels. Neither publishes the distance or the measurement conditions. A gap of a few dB(A) can come from the method as much as from the unit.

Indoor unit, in the room

Cooling, every published value

Outdoor unit, outside

Highest published value

Measurements taken by each manufacturer using its own method: read them separately, not as a ranking.

Sources: KINGHOME POLARIS R32 sheet distributed by AirGreen (34 to 53 dB(A) indoors, 55 dB(A) outdoors); GREE Canada EXTRÊME R32 brochure no. 032025 (49/46/45/42/40/38/35 dB(A), 59 dB(A) outdoors). The GREE AIRY R32 brochure, for the same model numbers, prints 56, 52 and 48 dB(A) indoors and 69 dB(A) outdoors, without stating the method; this page follows the EXTRÊME brochure.

Installation

Same published dimensions outside, two widths inside, two circuits

Both manufacturers publish exactly the same dimensions and weight for the outdoor unit. What changes is elsewhere: the width of the indoor unit, the electrical protection, the gas pipe diameter and the refrigerant charge.

Outdoor units, front view, same scale

POLARIS R32 outdoor unit
EXTRÊME R32 outdoor unit
POLARIS R3237 23/32 × 25 63/64 × 15 53/64 inwidth × height × depth · 94.8 lb
EXTRÊME R3237 23/32 × 25 63/64 × 15 53/64 inwidth × height × depth · 94.8 lb

Each dashed frame has the published width and height, at the same scale; the AirGreen photo of the series sits inside it, for identification. Neither document gives clearances: they appear in the manual supplied with the outdoor unit.

On the same footprint, four published values that differ

POLARIS R32Gas 1/2 in · 54.7 oz of R-32maximum protection 20 A · 55 dB(A) outdoors
EXTRÊME R32Gas 5/8 in · 47.6 oz of R-32maximum protection 25 A · 59 dB(A) outdoors

Indoor units to scale

POLARIS R3239 59/64 × 13 7/64 × 9 61/64 in · 32 lb
POLARIS R32 indoor unit
39.92 in
EXTRÊME R3243 45/64 × 13 21/32 × 10 1/8 in · 38.6 lb
EXTRÊME R32 indoor unit
43.70 in

Width × height × depth, per each manufacturer. The difference in width is 3.78 in. AirGreen photos of each series, for identification; the dimensions prevail.

Installation, 18,000 BTUPOLARIS R32EXTRÊME R32
Electrical protectionPer the manufacturer; 208/230 VMOCP 20 A (MCA 16 A)MOP 25 A (MCA 20 A)
Liquid – gas diameters1/4 – 1/2 in1/4 – 5/8 in
Maximum piping length131 ftpublished minimum: 10 ft131.2 ft
Precharged length25 ftadd 0.2 oz/ft beyond24.6 ftGREE AIRY R32 brochure (same model numbers, same AHRI number): add 0.4 oz/ft beyond; the EXTRÊME brochure does not give this length.
Maximum height differenceNot published by the manufacturer82 ft
Outdoor unit W × H × D, weight37 23/32 × 25 63/64 × 15 53/64 in, 94.8 lb37 23/32 × 25 63/64 × 15 53/64 in, 94.8 lb
Indoor unit, weight39 59/64 × 13 7/64 × 9 61/64 in, 32 lb43 45/64 × 13 21/32 × 10 1/8 in, 38.6 lb
Dehumidification1.8 L/h1.8 L/h
Rated heating / cooling range−30 to 30 °C / −29 to 50 °C−30 to 30 °C / −29 to 50 °C
Refrigerant: factory chargeR-32, 54.7 ozR-32, 47.6 oz

POLARIS R32: KINGHOME sheet distributed by AirGreen (undated). EXTRÊME R32: GREE Canada brochure no. 032025; the GREE AIRY R32 brochure prints, for the same model, MCA 21 A and maximum protection 25 A. MCA: minimum current the wires must be able to carry. MOP or MOCP: maximum protection rating. A master electrician sizes the circuit from the nameplate and the Code.

Frequently asked questions

What people ask about these two wall units at 18,000 BTU

Is it the same product under two brands?

The documents do not say so, and the records differ. They are two distinct AHRI certificates (218640147 and 215386340), listed in NEEP under two series (“POLARIS” and “Airy”), with indoor units of different widths and 16 certified measures out of 19 that are not identical. The two manufacturers do publish the same dimensions and weight for the outdoor unit.

Is the estimated heating cost the same?

Yes, in our estimate: it is based on Region V HSPF2, which is 8.0 for both. The yearly gap comes from cooling, where the certified SEER2 values are 24.5 and 27.5.

Which one heats more in extreme cold?

It depends on the temperature. At −15 °C, NEEP gives the POLARIS R32 16,500 BTU/h at maximum and the EXTRÊME R32 18,000. At −30 °C, 11,000 and 10,800 BTU/h. Both are measured at the same temperatures.

Which breaker for each?

KINGHOME lists a maximum protection (MOCP) of 20 A and an MCA of 16 A for the POLARIS R32. GREE lists a maximum protection (MOP) of 25 A and an MCA of 20 A for the EXTRÊME R32. Both run on 208/230 V; a master electrician sizes the circuit.

Do the pipes have the same diameters?

Not on the gas line: 1/4 – 1/2 in for the POLARIS R32, 1/4 – 5/8 in for the EXTRÊME R32. Each unit's installation manual prevails.

Are they eligible for grants?

Eligibility depends on the official list in force on the purchase date. This page promises no amount; the current list is checked when the quote is prepared.

Certified record

Every AHRI and NEEP value

Certified valuePOLARIS R32EXTRÊME R32
Cooling
Rated capacity at 35 °C18,000 BTU/h18,000 BTU/h
SEER224.527.5
EER213.6514.30
Heating, same conditions
HSPF2 Region IV9.510.0
HSPF2 Region V8.08.0
8.3 °C: min. / rated / max.BTU/h4,400 / 18,000 / 22,0005,000 / 18,600 / 23,000
8.3 °C: COP min. / rated / max.5.37 / 3.91 / 3.265.23 / 4.01 / 3.24
−8.3 °C: min. / rated / max.BTU/h7,900 / 20,400 / 21,0008,000 / 19,500 / 20,100
−8.3 °C: COP min. / rated / max.2.89 / 2.00 / 2.002.61 / 1.90 / 1.90
−15 °C: min. / rated / max.BTU/h6,700 / 16,500 / 16,5006,800 / 18,000 / 18,000
−15 °C: COP min. / rated / max.2.81 / 1.80 / 1.802.49 / 1.80 / 1.80
Coldest point
Test temperature−30 °C (−22 °F)−30 °C (−22 °F)
Capacity min. / max.5,000 / 11,000 BTU/h5,100 / 10,800 BTU/h
COP at maximum capacity1.401.23
Listings and refrigerant
ENERGY STAR / cold climate (NEEP)Yes / YesYes / Yes
ENERGY STAR directory, markets listedCanadaUnited States, Canada
AHRI certificate · NEEP record218640147 · 505227215386340 · 389441
RefrigerantGWP per the IPCC (AR4); ASHRAE 34 classR-32 · GWP 675 · A2LR-32 · GWP 675 · A2L

higher marks the higher value of the same measure, under the same conditions. It is not a recommendation. Capacities and COPs by point are not highlighted: the order changes depending on the point read.

Both are on the AirGreen website.

To choose for your room, talk to our team: bring the room dimensions, the planned outdoor location and your current heating.