TCL APEX XS and MIDEA EVOX G3, 36,000 BTU

Home / Comparisons / 3-ton central heat pumps

Comparison · Central heat pump · 3 tons

TCL APEX XS and MIDEA EVOX G3, two 3-ton central systems side by side

Two 3-ton central heat pumps offered by AirGreen, both ENERGY STAR cold climate per NEEP. The TCL APEX XS runs on R-32 and its outdoor unit comes in white or black; the MIDEA EVOX G3 runs on R-454B. NEEP tests them at the same four temperatures, from 8.3 °C to −30 °C.

SEER2 18.0 and 18.0HSPF2 Region V 8.0 and 8.2At −15 °C: 36,000 and 37,400 BTU/hAt −30 °C: 18,800 and 27,600 BTU/h
Estimated operating cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for the same 36,000 BTU/h house in Montréal, at Hydro-Québec Rate D, taxes included. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the reference. Both systems are certified at 36,000 BTU/h in cooling.

How this amount is calculated
  1. Heat needed over the winter. A house whose heat loss reaches 36,000 BTU/h ( kW) at −23.1 °C, Montréal’s design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for round-the-clock heating, all winter. Heating degree-days (base 18 °C) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours a day (“Heating” slider), the heat is reduced in the same proportion, for the heat pump and the baseboards alike: a simplification that ignores the recovery after a setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup planned for when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 36,000 BTU/h ÷ SEER2 × hours per day × 60 days ÷ 1,000: the method of Hydro-Québec’s air-conditioning calculator, with the SEER2 seasonal efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day: that is a maximum, since a variable-speed unit slows down once the room is at the right temperature.
  4. Price. Hydro-Québec Rate D in effect April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ beyond; the average price, 9.104¢, is the one Hydro-Québec’s calculators use. GST and QST included. The network access fee, the same with or without a heat pump, is not counted.

AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The actual bill depends on the house, insulation, settings and use; this amount is not a promise.

The footprint

Outside, on the same pad: height, width and floor space

The APEX XS outdoor unit is the lower of the two and the lighter. The EVOX G3 outdoor unit is taller and takes up less ground area. The dashed frames are drawn to the dimensions published by each manufacturer, at the same scale.

View
APEX XS finish
Height 33 3/4 in Height 38 3/8 in
TCL H36SDH20XQC outdoor unit, white finishTCL H36SDH20XQC outdoor unit, black finish
MIDEA MO1SE-H36B-2A outdoor unit
Width 43 1/8 in Width 38 9/16 in

Outdoor unit height

APEX XS33 3/4 in
EVOX G338 3/8 in

Ground area, width × depth

43 1/8 × 19 7/16 in5.8 sq ft
38 9/16 × 16 3/8 in4.4 sq ft

Outdoor unit net weight

APEX XS165 lb
EVOX G3204 lb

Indoor unit height

APEX XS46 7/16 in
EVOX G358 1/8 in

Front view: frames at the published width and height, to scale; each photo is placed in its frame and remains a photo taken in perspective. Views from above: diagrams to scale, drawn by AirGreen from the dimensions and the clearance figure in each installation manual. Ground area calculated by AirGreen: width × depth ÷ 144. Sources: TCL H36SDH20XQC / H36APH20UDE submittal sheet and TCL APEX XS installation manual (p. 22); MIDEA MAUSE-H36B-2A / MO1SE-H36B-2A submittal sheet and MIDEA EVOX Extreme Heat installation manual (p. 12, fig. C-1). Both APEX XS finishes carry the same model number, H36SDH20XQC.

From 8 to −30 °C

Four certified temperatures, placed on the same thermometer

For each unit, NEEP publishes test points at 8.3 °C, −8.3 °C, −15 °C and −30 °C. Each point on the chart is a value from the certificate; the dotted lines link each unit’s points, and nothing is measured between two points.

APEX XS TCLEVOX G3 MIDEASource: NEEP, records 505368 and 387396.
APEX XS: the same rated capacity at three temperaturesThe certificate gives a rated capacity of 36,000 BTU/h at 8.3 °C, at −8.3 °C and at −15 °C. At −15 °C, the maximum capacity is also 36,000 BTU/h.
EVOX G3: a maximum capacity above the rated capacityThe certificate gives a maximum of 47,000 BTU/h at 8.3 °C, 41,500 at −8.3 °C and 37,400 at −15 °C, for a rated capacity of 37,000 BTU/h at 8.3 °C.
At −30 °C, both are measuredA maximum of 18,800 BTU/h for the APEX XS (COP 1.20) and 27,600 BTU/h for the EVOX G3 (COP 1.56), at the same test temperature.

At −30 °C, the certificate gives a minimum capacity and a maximum capacity, with no rated value: the “Rated capacity” view therefore stops at −15 °C. The COP shown is the one NEEP publishes at the maximum capacity of each point.

Extreme cold

Below −15 °C: every published figure, at its exact temperature

NEEP certifies both units at −15 °C and at −30 °C, the same temperatures: those two rows compare directly. Neither TCL nor MIDEA publishes a capacity table between those two points for these combinations; at the temperatures in between, the page gives the range between the two certified points and what each manufacturer writes.

What each manufacturer also writes. TCL: the APEX XS specification sheet states continuous heating down to −30 °C (−22 °F) and the submittal sheet gives a “Capacity Ratio” of 100% at −15 °C (5 °F). MIDEA: the submittal sheet for this combination states “100% heating output down to −13°F” and specifies in a note that its rated heating capacity at −25 °C (−13 °F) is 100%. These statements are percentages; the page does not convert them to BTU/h.
Documented features

What each manufacturer writes, row by row

TCL APEX XS submittal sheet, specification sheet and installation manual; MIDEA EVOX G3 submittal sheet, installation manual and leaflet. Each row repeats what the manufacturer writes.

Compressor

APEX XS: variable-speed rotary MTH420UKQC8FU (submittal sheet).

EVOX G3: twin-cylinder rotary EKPQ420D1UMUA; “M-Powevi” vapour injection in extreme cold (leaflet).

Extreme cold and defrost

APEX XS: heating stated down to −30 °C; automatic defrost lasting 2 to 10 minutes (installation manual).

EVOX G3: heating stated down to −30 °C; enhanced defrost setting; base pan and crankcase heaters included as standard (submittal sheet, manual).

Fan and airflow

APEX XS: 1/2 HP ECM motor; 1,200 CFM in Turbo mode; constant airflow up to 0.8 in w.c.

EVOX G3: 5 speeds, 971 to 1,236 CFM; constant airflow up to 1.0 in w.c.

Controls and app

APEX XS: compatible with 24 V thermostats; RS485 wall controller for the dehumidification, energy-saving and sleep functions (specification sheet).

EVOX G3: MIDEA 120N wall controller, offered with built-in Wi-Fi, a wireless remote or another manufacturer’s 24 V thermostat (submittal sheet).

Indoor unit: positions and power supply

APEX XS: vertical upflow, downflow or horizontal mounting; automatic detection of 115 V or 230 V.

EVOX G3: horizontal mounting, left or right, or vertical, up or down; compatible with 115 V and 230 V.

Optional electric backup heat

APEX XS: 5, 10 or 15 kW element (specification sheet).

EVOX G3: three-stage kit, up to 25 kW (submittal sheet, leaflet).

Sound

The sound of each one, per its manufacturer

TCL and MIDEA publish the sound of the indoor unit and of the outdoor unit. TCL speaks of sound pressure; MIDEA writes “Noise Level”. Neither document states the distance or the measurement method: read the values separately.

dB(A)

How to read these numbers. dB(A) measures noise level as the ear perceives it: the lower the number, the quieter the unit. Each dot is a value published by the manufacturer.

Why this is not a ranking. Two manufacturers, two documents, with no distance or measurement method stated. Different or unknown method: not comparable.

Indoor unit, in the basement or a closet

Published values

TCL publishes a single value for the indoor unit; MIDEA publishes one per fan speed.

Outdoor unit, outside

Published values

TCL publishes two values, “55 / 64”, without saying what each one corresponds to; MIDEA publishes one.

Measurements taken by each manufacturer with its own unstated method: read them separately, not as a ranking.

Installation

In the basement, then along the piping

Indoor units, height and width to scale

TCL H36APH20UDE indoor unit
APEX XS 21 in wide, 46 7/16 in highEVOX G3 17 1/2 in wide, 58 1/8 in high

Frames to scale, drawn at the published width and height. The TCL unit is a photo placed in its frame. MIDEA does not publish a stand-alone photo of the MAUSE-H36B-2A: it is shown as a diagram. Depth: 21 in and 21 1/2 in. Weight: 134.2 lb and 149 lb.

Line-set length and refrigerant to add

AirGreen calculation from the submittal sheets: length beyond the 25 ft precharged × 0.27 oz per foot (TCL, R-32) or 0.7 oz per foot (MIDEA, R-454B). Maximum published length: 164 ft (TCL) and 246 ft (MIDEA). The TCL manual asks for a line set of at least 15 ft.

InstallationAPEX XSEVOX G3
Maximum piping length164 ftTCL submittal sheet and installation manual.246 ftMIDEA submittal sheet and installation manual, rev. 5.
Precharged length25 ft0.27 oz of R-32 per foot beyond.25 ft0.7 oz of R-454B per foot beyond.
Maximum height difference98 ft98 ft98.4 ft per the installation manual.
Liquid – gas line diameters3/8 – 3/4 in3/8 – 3/4 in
Outdoor unit W × H × D, weight43 1/8 × 33 3/4 × 19 7/16 in, 165 lb38 9/16 × 38 3/8 × 16 3/8 in, 204 lb
Indoor unit, weight21 × 46 7/16 × 21 in, 134.2 lb17 1/2 × 58 1/8 × 21 1/2 in, 149 lb
Minimum clearances, unit alonebehind · sides · front3.94 in · 3.94 and 11.81 in · 39.37 inTCL manual, p. 22, walls on three sides.4 in · 4 and 14 in · 20 inMIDEA manual, fig. C-1; 20 in at the front when two of the other three sides are clear.
Electrical protectionoutdoor unit, 208/230 VMCA 30 A · MOP 50 AIndoor unit: MCA 5 A, MOP 15 A.MCA 29 A · MOP 30 AIndoor unit: MCA 6 A at 208/230 V, MOP 15 A.
Factory refrigerant charge105.8 oz of R-32127 oz of R-454B
Dehumidification4 pints per hourTCL specification sheet.3.41 litres per hourMIDEA submittal sheet.
Stated heating / cooling range−30 to 27 °C / −15 to 55 °C−30 to 24 °C / −30 to 50 °C

Sources: TCL “Apex XS Series Unitary HP + Advantage P Series AHU” submittal sheet, TCL “APEX XS & Auto Voltage AHU” specification sheet and TCL APEX XS installation manual; MIDEA “Extreme Heat AHU Series” submittal sheet and MIDEA EVOX Extreme Heat installation manual. The TCL specification sheet prints 33 3/8 in for the outdoor unit height, next to 858 mm: the page follows the 858 mm and the submittal sheet, that is, 33 3/4 in. Both manuals ask that the unit be protected from snow; the MIDEA manual asks that it be mounted at least 11.8 in above the expected snow.

Frequently asked questions

What people ask about these two central systems

Where do the two systems differ the most?

At −30 °C. NEEP certifies a maximum of 18,800 BTU/h for the APEX XS and 27,600 BTU/h for the EVOX G3, at the same temperature. At −15 °C, the certified maximum capacities are 36,000 and 37,400 BTU/h.

Do the white and the black APEX XS have the same values?

Both finishes offered by AirGreen carry the same model number, H36SDH20XQC. The TCL specification sheet gives a single set of values and a single AHRI certificate for this model, 218453817.

Which one takes up less space outside?

It depends on the measure. The APEX XS outdoor unit is 33 3/4 in high and the EVOX G3 outdoor unit, 38 3/8 in. On the ground, the APEX XS takes up 43 1/8 × 19 7/16 in and the EVOX G3, 38 9/16 × 16 3/8 in. The clearances each manual asks for are added to that; they are drawn in the section “The footprint”.

R-32 or R-454B, what does it change?

Both refrigerants are class A2L under the ASHRAE 34 standard. Their global warming potential per the IPCC (AR4) is 675 for R-32 and 466 for R-454B. Our page R-32 or R-454B covers both in detail.

Is the winter cost very different?

The estimated cost uses Region V HSPF2, 8.0 for the APEX XS and 8.2 for the EVOX G3: the yearly gap shown above follows from that. In summer, both have the same SEER2, 18.0, so the same estimate.

Which one makes less noise?

TCL publishes 57 dB(A) for the indoor unit and “55 / 64” dB(A) for the outdoor unit; MIDEA publishes 33 to 48 dB(A) depending on the speed for the indoor unit and 63 dB(A) for the outdoor unit. No document states the method: these numbers cannot be used to rank the units.

Are they eligible for rebates?

Per NEEP, both combinations are ENERGY STAR and ENERGY STAR cold climate. Eligibility depends on the official list in force on the date of purchase; this page promises no amount.

Certified data sheet

All the AHRI and NEEP values

Certified valueAPEX XSEVOX G3
Cooling
Rated capacity at 35 °C36,000 BTU/h36,000 BTU/h
SEER218.018.0
EER211.012.0
Heating, same conditions
HSPF2 Region IV9.510.0
HSPF2 Region V8.08.2
8.3 °C: min. / rated / max.BTU/h22,800 / 36,000 / 45,00011,400 / 37,000 / 47,000
8.3 °C: COP min. / rated / max.4.51 / 3.60 / 3.504.45 / 3.50 / 3.27
−8.3 °C: min. / rated / max.BTU/h22,000 / 36,000 / 36,00011,000 / 33,000 / 41,500
−8.3 °C: COP min. / rated / max.2.60 / 2.30 / 2.302.58 / 2.50 / 2.21
−15 °C: min. / rated / max.BTU/h22,800 / 36,000 / 36,0008,900 / 37,400 / 37,400
−15 °C: COP min. / rated / max.2.00 / 1.85 / 1.852.16 / 1.90 / 1.90
Coldest point — same temperature for both
Test temperature−30 °C (−22 °F)−30 °C (−22 °F)
Min. / max. capacity18,800 / 18,800 BTU/h4,700 / 27,600 BTU/h
COP at maximum capacity1.201.56
Listings and refrigerant
ENERGY STAR / cold climate (NEEP)Yes / YesYes / Yes
AHRI certificate · NEEP record218453817 · 505368215471343 · 387396
RefrigerantGWP per the IPCC (AR4); ASHRAE 34 classR-32 · GWP 675 · A2LR-454B · GWP 466 · A2L

higher marks the higher value of the same measure, under the same conditions. It is not a recommendation. Capacities and COPs at each point are not highlighted; they are compared in “From 8 to −30 °C” and “Extreme cold”. When a TCL or MIDEA document departs from the certificate (TCL, for example, writes a maximum of 46,000 BTU/h at 8.3 °C, and a COP of 2 at −15 °C in its submittal sheet), the page follows the certificate.

Both are on the AirGreen website.

To choose for your home, talk it over with our team: bring the heated floor area, the condition of your ducts and the spot planned for the outdoor unit.

Sources and documents

Where every figure comes from