BRADFORD WHITE LE110U3-1NCL Commercial Electric Water Heater (10 gallons) | Montreal, Laval, Longueuil, South Shore & North Shore

In stock
SKU: LE110U3-1NCL
38 L10 US gal of storage
1,500 Wper element
3 yrstank warranty
Talk to an expert · 514 316-2973
3-year tank warranty, 1-year parts3/4 in NPT connections240 V
01 · Why this model

What sets the Bradford White LE110U3 apart

48 lb

Shipping weight

Bradford White sheet C1412 lists an approximate shipping weight of 48 lb for the LE110U3.

17 1/2 in

Overall height

The tank stands 17 1/2 in from floor to top with a 16 in jacket diameter.

6 GPH

Recovery at 1,500 W

It recovers 6 US gallons per hour at a 100 °F rise with its single 1,500 W element.

150 psi

Working pressure

The tank is tested at 300 psi and rated for 150 psi working pressure.

02 · How it works

Cold water at the bottom, hot water on top

Cold watergoes down the dip tubeHot waterdrawn from the topUpper elementand its thermostatLower elementand its thermostatCold waterarrives at the bottom
  1. Cold water arrives at the bottom of the tank. Hot water, being lighter, stays on top, where it is drawn.
  2. The elements, each controlled by its thermostat, bring the water back to the set temperature.
  3. Foam insulation limits the heat lost while the water waits.
03 · Will it fit?

Check the height and the way in before our visit

It travels upright. Measure the ceiling at the spot and the narrowest door on the way.

in
in

Unit: 17.5 in tall (445 mm), 16 in across (406 mm), about 48 lb shipping weight. The clearances the manufacturer requires are checked on site.

04 · Your current tank

How old is yours?

The year it was made is on the tank’s rating plate. Enter it.

Signs it is wearing out

  • Hot water runs out sooner than it used to.
  • The water comes out slightly reddish.
  • Rust shows at the bottom of the tank.
  • Moisture or drips around the unit.

Manufacturers announce a 10 to 15 year life. Many insurers require replacement after 10 or 12 years and may refuse a water damage claim past that age (CAA-Québec). Check your policy.

05 · Installation

What the spot needs, and who does what

240 V circuit1,500 W element. A dedicated circuit, sized by our electrician.
3/4 in NPT waterCold inlet, hot outlet and an accessible shut-off valve.
T&P valveTemperature and pressure relief valve, with its discharge line.
Pan and detectorDrip pan under the tank and a leak detector: strongly recommended (CAA-Québec).
60 °C, 49 °CTank set to 60 °C against bacteria; 49 °C max at the shower and tub (Construction Code, art. 2.2.10.7).

AirGreenFree visit and quote, electrical connection (RBQ licence 5645-9605-01, subclass 16), start-up.

PlumberWater connections and relief valve by a master pipe-mechanic (CMMTQ).

YouA photo of the rating plate, the spot and the stairs saves us a trip.

06 · Maintenance

A few habits that make it last

  1. Start-up daySetting the temperature, with you.
  2. Every yearPartial drain to flush sediment, and a test of the relief valve.
  3. Depending on your waterAnode inspection: it wears so the tank steel does not. In hard water it goes faster.
07 · Spec sheet

Every figure, with its source

Capacity and performance
Model
LE110U3-1NCL
Capacity
10 US gal · 38 L
Recovery
6 US gal/h · 23 L/h
Electrical
Supply
240 V, single phase
Element
1,500 W
Element type
Screw-in copper (Incoloy on request)
Dimensions and connections
Height
17.5 in · 445 mm
Diameter
16 in · 406 mm
Shipping weight (approx.)
48 lb · 22 kg
Water connections
3/4 in NPT
Build and warranty
Inner lining
Vitraglas with Microban
Limited warranty, tank
3 years
Limited warranty, parts
1 year

Manufacturer data. Detailed sources at the bottom of the page.

08 · Same family

The size below and above

09 · Questions

What people ask us most

Is there a LogisVert grant for this water heater?

No. Hydro-Québec’s LogisVert guide (version 1.10, September 15, 2026) lists no water heater among its eligible measures. At quote time we check other programs that could apply to your address.

What temperature should the tank be set to?

To 60 °C, as the Québec government recommends, to limit bacterial growth. At shower and tub valves, the Construction Code caps the water at 49 °C: that is the job of the valve or a thermostatic mixing valve.

Who does the installation?

AirGreen does the visit, the electrical connection under its RBQ licence (subclass 16) and the start-up. The water connections are done by a master pipe-mechanic (CMMTQ).

10 · AirGreen

We check the spot before we sell you anything

Free on-site estimate, written quote. Send a photo of your current tank and its plate, and we prepare the visit.

Book my free estimate
Sources checked November 2, 2026.
  1. Bradford White Canada ElectriFLEX LD Utility spec sheet C1412-1024 CANADA · cdn.shopify.com
  2. Québec.ca, “Eau chaude”, updated November 5, 2025 (186 L/day, 7 °C water, 60 °C, volumes per use).
  3. Québec Construction Code, Chapter III Plumbing, art. 2.2.10.7 (RBQ).
  4. CAA-Québec, “Chauffe-eau: quelle capacité choisir”, updated June 29, 2026.
  5. Hydro-Québec, LogisVert residential participation guide, version 1.10, September 15, 2026.

Costs shown are indicative estimates before tax.

A 10 US gallon tank to supply a kitchenette or a bar with hot water, without running a new line

When fitting out a staff kitchenette, a bar or a service counter, hot water is often the forgotten item. The main water heater is at the other end of the building, and extending a line all the way there takes time, opens walls and gives water that is slow to arrive. The Bradford White LE110U3-1NCL commercial electric water heater offers a more direct solution: a 10 US gallon tank (8 imperial gallons, 38 L) installed near the sink, producing its own hot water. AirGreen installs it in offices, businesses and restaurants in Montreal, Laval, Longueuil, the South Shore and the North Shore.

Renovation: adding hot water where there is none

In a commercial renovation, every metre of piping has a price and every wall opening stretches out the work. A local tank avoids those detours. All it needs is a cold water supply, an electrical circuit and a discharge point for the relief valve. Hot water then travels a very short distance to the tap, which limits waiting and waste.

This solution also helps when a leased space simply has no hot water, or when the main water heater barely keeps up with existing demand and you do not want to overload it with a new fixture.

Examples of use

  • An office kitchenette, for lunch dishes and counter cleaning.
  • A restaurant’s bar sink, far from the kitchen, where glasses are rinsed during the evening.
  • The service counter of a café or a bakery, for washing utensils.
  • A clinic’s exam room, where a washbasin must provide hot water quickly.

Manufacturer data for the LE110U3-1NCL

  • Capacity: 10 US gallons (8 imperial gallons, 38 L).
  • Recovery: 6 US gallons per hour (5 imperial gallons) at a 100 °F rise; 23 L/h at a 56 °C rise, based on 1,500 W.
  • Element: a single immersed screw-in element, copper; INCOLOY-type element available on request.
  • Power: 1,500 W.
  • Power supply: single-phase use only.
  • Water connections: 3/4 in. (19 mm) NPT, factory-installed dielectric fittings.
  • Tank: Vitraglas lining with Microban.
  • Diameter: 16 in. (406 mm). Weight: 48 lb (22 kg).

Sizing it right: reserve and recovery

Two figures describe what the unit can deliver. First, its 10 US gallon reserve, available immediately. Second, its recovery: according to Bradford White, the 1,500 W element heats 6 US gallons per hour at a 100 °F rise. For a kitchenette or a bar sink, that is a good balance: the reserve covers filling a sink or a series of rinses, then the unit recovers during quieter moments.

If the sink is used to wash dishes without interruption, or if several fixtures must be supplied, a larger tank or a higher power rating will be preferable. We do that calculation with you based on actual use before recommending a model.

Power and electrical supply

The LE110U3-1NCL runs on a single 1,500 W element, single-phase only. It is a modest load that connects easily to an existing commercial panel. For this series, the manufacturer’s limitations table provides for power ratings from 1,500 W to 6,000 W depending on voltage, and from 1,500 W to 3,000 W only at 120 V; conversion kits are listed for 120, 208, 240, 277, 380, 480 V.

The exact voltage of the unit delivered and the circuit that will supply it are confirmed in our written quote, after we check your panel. We make the electrical connections under our RBQ licence.

Location, anchoring and safety

At 16 in. in diameter and 48 lb empty, the LE110U3-1NCL fits in a closet, under a sturdy shelf or in a utility room next to the sink. When space is tight, we confirm the unit’s exact height with the manufacturer before ordering. Once filled, the tank is considerably heavier: it must rest on a surface able to carry it and be firmly secured.

The relief valve, mandatory on every tank, must be connected to a compliant discharge, and the element must remain accessible for service. Those details, more than the size of the unit, often determine the right location.

Protecting the tank and the element

The inside of the tank is lined with Vitraglas with Microban, an antimicrobial technology, and the factory-installed dielectric fittings limit corrosion between the piping and the tank. The standard element is copper; an INCOLOY-type element, more resistant to corrosion, is available on request. We recommend it when the building’s water is particularly hard.

Listings and warranty

According to Bradford White’s documentation, all models are ETL listed, and applicable models are CSA verified for energy performance in accordance with C191.1-M90. The "3" suffix in the model number corresponds to the 3-year limited tank warranty and 1 year on parts.

Installation of the Bradford White LE110U3-1NCL by AirGreen

AirGreen is a family business established in Montreal, active for more than fifteen years in heating, ventilation and air conditioning and holder of RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical). In a renovation project, we coordinate with your contractor so the water heater is planned at the right time. Our work includes:

  • a free on-site assessment of the use, the location and the available electrical circuit;
  • removing the old unit where applicable, then disposing of it;
  • connecting the cold and hot water in 3/4 in.;
  • installing the relief valve and its discharge;
  • the electrical connections, made under our RBQ licence;
  • commissioning and setting the temperature for the intended use;
  • maintenance advice: occasional flushing, testing the relief valve and checking the element.

Service area

We work in Montreal, from downtown to Griffintown and Mile End, in Laval, Longueuil, Saint-Bruno and throughout the South Shore and the North Shore.

Request your free on-site estimate for the Bradford White LE110U3-1NCL. You will receive a detailed written quote, and financing options are available for your project.