Potable water safety
Two nested copper tubes with vented leak ports separate potable water from boiler water, so a leak shows at the fittings instead of contaminating the water.
A tank rarely runs out over a day. It runs out over an hour. Describe your busiest hour.
An indirect’s first-hour rating depends on the boiler; the test conditions are in the spec sheet. Method: the first-hour rating should equal or exceed the hot water of your busiest hour (Natural Resources Canada). CAA-Québec rule of thumb: 40 gal for 1 or 2 people, 60 gal for 3 or 4, 80 to 100 gal for 5 or more. Volumes: Québec.ca.
Two nested copper tubes with vented leak ports separate potable water from boiler water, so a leak shows at the fittings instead of contaminating the water.
As with the TurboMax, potable water is heated on demand in the coils; the 120 gal tank holds boiler water.
The 120-9A is the ASME version of the DoubleMax 120: 125 psi maximum allowable working pressure, 50 psi relief valve and 163 psi hydrostatic test.
Thermo 2000 covers the tank and coils for 15 years residential (10 years commercial) and parts for 2 years.
The year it was made is on the tank’s rating plate. Enter it.
Manufacturers announce a 10 to 15 year life. Many insurers require replacement after 10 or 12 years and may refuse a water damage claim past that age (CAA-Québec). Check your policy.
AirGreenFree visit and quote, coordination of the work.
HeatingBoiler connection by a hydronic heating contractor (RBQ 15.4).
PlumberWater connections and relief valve by a master pipe-mechanic (CMMTQ).
YouA photo of the rating plate, the spot and the stairs saves us a trip.
Manufacturer data. Detailed sources at the bottom of the page.
No. Hydro-Québec’s LogisVert guide (version 1.10, September 15, 2026) lists no water heater among its eligible measures. At quote time we check other programs that could apply to your address.
Yes. An indirect water heater has no element: it is heated by water from a boiler. The boiler connection is done by a hydronic heating contractor (RBQ 15.4) and the water connections by a master pipe-mechanic (CMMTQ).
To 60 °C, as the Québec government recommends, to limit bacterial growth. At shower and tub valves, the Construction Code caps the water at 49 °C: that is the job of the valve or a thermostatic mixing valve.
Often, yes. According to CAA-Québec, many insurers require replacement after 10 or 12 years and may refuse a water damage claim past that age. The manufacture date is on the rating plate.
It delivers 3,145 L of hot water in the first hour, with the boiler stated in the spec sheet. CAA-Québec’s rule of thumb suggests 40 gal for 1 or 2 people, 60 gal for 3 or 4 and 80 to 100 gal for 5 or more; the “Your home” tool above accounts for your busiest hour.
AirGreen does the visit and the quote and coordinates the work. The water connections are done by a master pipe-mechanic (CMMTQ) and the boiler connection by a hydronic heating contractor (RBQ 15.4).
Free on-site estimate, written quote. Send a photo of your current tank and its plate, and we prepare the visit.
Book my free estimateCosts shown are indicative estimates before tax.
In a seniors’ residence, an early childhood centre, a hotel or a commercial kitchen, hot water is an essential service and the tank that produces it is often subject to specific requirements from the engineer or the insurer. The Thermo 2000 DoubleMax 120-9A indirect water heater fits this context: a 120 US gallon tank, a 55.6 sq. ft. double-wall copper heat exchanger and a maximum pressure of 125 psi stated for the ASME version. It is fed by an electric boiler. AirGreen installs it in Montreal, Laval, Longueuil, on the South Shore and on the North Shore.
On the DoubleMax 120-9A specification sheet, the maximum pressure is stated as 125 psi (ASME). The American Society of Mechanical Engineers code governs the design of pressure vessels; in many commercial and institutional projects, the engineer’s drawings or the insurer’s conditions require a tank of this type. Choosing the right version from the start avoids reordering and a site delay. We check this requirement with you before quoting.
The maximum working pressure of this model is 125 psi. In some areas, the municipal supply pressure or that of a booster pump can come close to it, especially on the lower floors of a building. We measure the pressure at the water entrance and install a pressure-reducing valve when needed. The relief valve is chosen according to this maximum pressure and the tank volume, and an expansion tank absorbs the expansion of the heated water. These three components work as a whole: they protect the tank, the piping and the users.
Thermo 2000’s table gives output in US gallons per hour, as first hour / continuous, according to boiler capacity, with cold water at 40 °F and boiler water at 180 °F. In an institutional building or a kitchen, the 140 °F and 160 °F columns are often the most useful:
Real output therefore depends on the electric boiler and on the building’s electrical service. We establish these two figures first, then read the table at the line that truly matches your installation.
A seniors’ residence concentrates baths and care in the morning. An early childhood centre washes dishes and hands all day long. A small hotel sees its guests shower at the same hour. A commercial kitchen needs hotter water for the pot sink. In each of these cases, the 120 US gallon reserve covers the peak while the electric boiler maintains production. A thermostatic mixing valve then delivers the right temperature for each use.
The exchanger’s copper pipes are double-wall: two thicknesses of metal separate the boiler water from the potable water. This design is often requested in public buildings, or when the heating loop contains an additive. It comes on top of the copper components’ compliance with the NSF 61 standard.
The tank weighs 530 lb empty and measures 28 in in diameter. Its exact height is confirmed with the manufacturer’s order sheet; we compare it with the free height of your mechanical room before ordering. The delivery route, the floor capacity once the tank is filled and access to a drain are checked during the visit. The boiler connection is 2 in NPT male; the size of the potable water connections is confirmed with the same sheet.
Thermo 2000 provides a 10-year commercial warranty and a 15-year residential warranty on the tank and copper coils, as well as a 2-year warranty on mechanical parts. The category that applies to your building is specified in writing with the quote.
AirGreen is a family business established in Montreal and active in heating, ventilation and air conditioning for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. For this tank, our service includes:
We work with institutions, property managers and businesses in Montreal, Laval, Longueuil, Brossard, Châteauguay, Saint-Jean-sur-Richelieu, Sainte-Thérèse, Repentigny and across the South Shore and the North Shore. The on-site estimate is free, the quote is written and financing is available.
Request your free quote for the Thermo 2000 DoubleMax 120-9A. Attach your engineer’s or insurer’s requirements: we will reply with a complete, compliant configuration.