THERMO 2000 DOUBLEMAX 120-9A Indirect Water Heater (120 gallons) | Montreal, Laval, Longueuil, South Shore & North Shore

In stock
SKU: DOUBLEMAX 120-9A
454 L120 US gal of storage
3,145 Lof hot water in the first hour
15 yrstank warranty
Talk to an expert · 514 316-2973
15-year tank warranty, 2-year parts
01 · Your home

Enough hot water for your busiest hour?

A tank rarely runs out over a day. It runs out over an hour. Describe your busiest hour.

Showers in the same hour35 L each, low-flow head, 6 minutes
2
A bathWe count 110 L (75 to 150 L depending on the tub)
The dishwasher13 L per cycle on average
Your peak hour: 83 LThis model, first hour: 3,145 L

An indirect’s first-hour rating depends on the boiler; the test conditions are in the spec sheet. Method: the first-hour rating should equal or exceed the hot water of your busiest hour (Natural Resources Canada). CAA-Québec rule of thumb: 40 gal for 1 or 2 people, 60 gal for 3 or 4, 80 to 100 gal for 5 or more. Volumes: Québec.ca.

02 · Why this model

What sets the Thermo 2000 DoubleMax 120-9A apart

Double wall

Potable water safety

Two nested copper tubes with vented leak ports separate potable water from boiler water, so a leak shows at the fittings instead of contaminating the water.

Instant

No stored potable water

As with the TurboMax, potable water is heated on demand in the coils; the 120 gal tank holds boiler water.

ASME

'A' version

The 120-9A is the ASME version of the DoubleMax 120: 125 psi maximum allowable working pressure, 50 psi relief valve and 163 psi hydrostatic test.

15 yrs

Residential warranty

Thermo 2000 covers the tank and coils for 15 years residential (10 years commercial) and parts for 2 years.

03 · How it works

The boiler heats the water without ever touching it

Boilerheat sourceboiler waterHeat exchangertwo separate circuitsHot waterto the houseCold waterfrom the mains
  1. When the tank calls for heat, its control starts the boiler loop.
  2. Boiler water and drinking water flow in two separate circuits: heat passes through the exchanger wall.
  3. No electric element: all the heat comes from the boiler that already heats the house.
04 · Your current tank

How old is yours?

The year it was made is on the tank’s rating plate. Enter it.

Signs it is wearing out

  • Hot water runs out sooner than it used to.
  • The water comes out slightly reddish.
  • Rust shows at the bottom of the tank.
  • Moisture or drips around the unit.

Manufacturers announce a 10 to 15 year life. Many insurers require replacement after 10 or 12 years and may refuse a water damage claim past that age (CAA-Québec). Check your policy.

05 · Installation

What the spot needs, and who does what

A boilerIts ratings are published with a 650,000 BTU/h boiler. The heating contractor checks yours.
Boiler loopCirculator or zone valve, with the tank control wired to the boiler.
waterCold inlet, hot outlet and an accessible shut-off valve.
T&P valveTemperature and pressure relief valve, with its discharge line.
Pan and detectorDrip pan under the tank and a leak detector: strongly recommended (CAA-Québec).
60 °C, 49 °CTank set to 60 °C against bacteria; 49 °C max at the shower and tub (Construction Code, art. 2.2.10.7).

AirGreenFree visit and quote, coordination of the work.

HeatingBoiler connection by a hydronic heating contractor (RBQ 15.4).

PlumberWater connections and relief valve by a master pipe-mechanic (CMMTQ).

YouA photo of the rating plate, the spot and the stairs saves us a trip.

06 · Maintenance

A few habits that make it last

  1. Start-up daySetting the temperature, with you.
  2. Every yearPartial drain to flush sediment, and a test of the relief valve.
  3. With the boilerThe heating contractor checks the loop, circulator and tank control during the boiler service.
07 · Spec sheet

Every figure, with its source

Capacity and performance
Model
DOUBLEMAX 120-9A
Capacity
120 US gal · 454 L
First-hour rating
831 US gal · 3,145 L
Continuous draw
783 US gal/h · 2,964 L/h
Reference boiler
650,000 BTU/h
Recovery
783 US gal/h · 2964 L/h
Dimensions and connections
Diameter
28 in · 711 mm
Shipping weight (approx.)
530 lb · 240 kg
Heat exchanger
Double-wall copper coils carrying potable water, vented leak ports, immersed in boiler water
Build and warranty
Drain valve
Brass
Limited warranty, tank
15 years
Limited warranty, parts
2 years

Manufacturer data. Detailed sources at the bottom of the page.

08 · Questions

What people ask us most

Is there a LogisVert grant for this water heater?

No. Hydro-Québec’s LogisVert guide (version 1.10, September 15, 2026) lists no water heater among its eligible measures. At quote time we check other programs that could apply to your address.

Do I need a boiler?

Yes. An indirect water heater has no element: it is heated by water from a boiler. The boiler connection is done by a hydronic heating contractor (RBQ 15.4) and the water connections by a master pipe-mechanic (CMMTQ).

What temperature should the tank be set to?

To 60 °C, as the Québec government recommends, to limit bacterial growth. At shower and tub valves, the Construction Code caps the water at 49 °C: that is the job of the valve or a thermostatic mixing valve.

Can my insurer require me to replace it?

Often, yes. According to CAA-Québec, many insurers require replacement after 10 or 12 years and may refuse a water damage claim past that age. The manufacture date is on the rating plate.

How many people is 120 gallons enough for?

It delivers 3,145 L of hot water in the first hour, with the boiler stated in the spec sheet. CAA-Québec’s rule of thumb suggests 40 gal for 1 or 2 people, 60 gal for 3 or 4 and 80 to 100 gal for 5 or more; the “Your home” tool above accounts for your busiest hour.

Who does the installation?

AirGreen does the visit and the quote and coordinates the work. The water connections are done by a master pipe-mechanic (CMMTQ) and the boiler connection by a hydronic heating contractor (RBQ 15.4).

09 · AirGreen

We check the spot before we sell you anything

Free on-site estimate, written quote. Send a photo of your current tank and its plate, and we prepare the visit.

Book my free estimate
Sources checked November 2, 2026.
  1. Thermo 2000 DoubleMax Specifications · www.thermo2000.com
  2. Thermo 2000 DoubleMax flyer EN · www.thermo2000.com
  3. Thermo 2000 DoubleMax performance tables · www.thermo2000.com
  4. Québec.ca, “Eau chaude”, updated November 5, 2025 (186 L/day, 7 °C water, 60 °C, volumes per use).
  5. Natural Resources Canada, water heater buying guide (75 L/person/day, first-hour rating).
  6. Québec Construction Code, Chapter III Plumbing, art. 2.2.10.7 (RBQ).
  7. CAA-Québec, “Chauffe-eau: quelle capacité choisir”, updated June 29, 2026.
  8. Hydro-Québec, LogisVert residential participation guide, version 1.10, September 15, 2026.

Costs shown are indicative estimates before tax.

A 120 US gallon indirect water heater in ASME version for institutional and commercial buildings

In a seniors’ residence, an early childhood centre, a hotel or a commercial kitchen, hot water is an essential service and the tank that produces it is often subject to specific requirements from the engineer or the insurer. The Thermo 2000 DoubleMax 120-9A indirect water heater fits this context: a 120 US gallon tank, a 55.6 sq. ft. double-wall copper heat exchanger and a maximum pressure of 125 psi stated for the ASME version. It is fed by an electric boiler. AirGreen installs it in Montreal, Laval, Longueuil, on the South Shore and on the North Shore.

Why choose the 120-9A version

On the DoubleMax 120-9A specification sheet, the maximum pressure is stated as 125 psi (ASME). The American Society of Mechanical Engineers code governs the design of pressure vessels; in many commercial and institutional projects, the engineer’s drawings or the insurer’s conditions require a tank of this type. Choosing the right version from the start avoids reordering and a site delay. We check this requirement with you before quoting.

Managing a 125 psi maximum pressure

The maximum working pressure of this model is 125 psi. In some areas, the municipal supply pressure or that of a booster pump can come close to it, especially on the lower floors of a building. We measure the pressure at the water entrance and install a pressure-reducing valve when needed. The relief valve is chosen according to this maximum pressure and the tank volume, and an expansion tank absorbs the expansion of the heated water. These three components work as a whole: they protect the tank, the piping and the users.

Manufacturer’s data

  • Capacity: 120 US gallons
  • Heat exchanger: double-wall copper in parallel helicoidal lines, exchange surface of 55.6 sq. ft.
  • Maximum pressure: 125 psi (ASME)
  • Maximum domestic hot water flow: 27 gpm, value to be reduced for high-temperature and continuous-flow applications
  • Boiler connection: 2 in NPT male
  • Drain valve: ¾ in brass ball valve, maximum working pressure of 150 psi
  • Diameter: 28 in
  • Weight: 530 lb (610 lb shipping)
  • Potable water: copper components meet the NSF 61 standard and the low lead requirements

Output at commercial temperatures

Thermo 2000’s table gives output in US gallons per hour, as first hour / continuous, according to boiler capacity, with cold water at 40 °F and boiler water at 180 °F. In an institutional building or a kitchen, the 140 °F and 160 °F columns are often the most useful:

  • 150,000 BTU/h (44 kW): 228 / 181 at 140 °F; 201 / 181 at 160 °F; 377 / 258 at 110 °F
  • 250,000 BTU/h (73 kW): 349 / 301 at 140 °F; 321 / 301 at 160 °F; 549 / 430 at 110 °F
  • 400,000 BTU/h (117 kW): 530 / 482 at 140 °F; 502 / 482 at 160 °F; 807 / 688 at 110 °F

Real output therefore depends on the electric boiler and on the building’s electrical service. We establish these two figures first, then read the table at the line that truly matches your installation.

Where the DoubleMax 120-9A fits

A seniors’ residence concentrates baths and care in the morning. An early childhood centre washes dishes and hands all day long. A small hotel sees its guests shower at the same hour. A commercial kitchen needs hotter water for the pot sink. In each of these cases, the 120 US gallon reserve covers the peak while the electric boiler maintains production. A thermostatic mixing valve then delivers the right temperature for each use.

A double-wall exchanger for potable water

The exchanger’s copper pipes are double-wall: two thicknesses of metal separate the boiler water from the potable water. This design is often requested in public buildings, or when the heating loop contains an additive. It comes on top of the copper components’ compliance with the NSF 61 standard.

Delivery and location

The tank weighs 530 lb empty and measures 28 in in diameter. Its exact height is confirmed with the manufacturer’s order sheet; we compare it with the free height of your mechanical room before ordering. The delivery route, the floor capacity once the tank is filled and access to a drain are checked during the visit. The boiler connection is 2 in NPT male; the size of the potable water connections is confirmed with the same sheet.

Manufacturer’s warranty

Thermo 2000 provides a 10-year commercial warranty and a 15-year residential warranty on the tank and copper coils, as well as a 2-year warranty on mechanical parts. The category that applies to your building is specified in writing with the quote.

Installation of the Thermo 2000 DoubleMax 120-9A by AirGreen

AirGreen is a family business established in Montreal and active in heating, ventilation and air conditioning for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. For this tank, our service includes:

  • confirmation of the ASME requirement, the supply pressure and the electric boiler’s capacity;
  • assessment of the mechanical room, free height, floor and delivery route;
  • removal of the old equipment;
  • connecting the exchanger to the boiler in 2 in, with circulator, isolation valves and air vents;
  • potable water connections, the pressure-reducing valve, the thermostatic mixing valve and the expansion tank;
  • the relief valve and its discharge pipe to the drain;
  • wiring the controls, commissioning and a yearly maintenance plan.

We work with institutions, property managers and businesses in Montreal, Laval, Longueuil, Brossard, Châteauguay, Saint-Jean-sur-Richelieu, Sainte-Thérèse, Repentigny and across the South Shore and the North Shore. The on-site estimate is free, the quote is written and financing is available.

Request your free quote for the Thermo 2000 DoubleMax 120-9A. Attach your engineer’s or insurer’s requirements: we will reply with a complete, compliant configuration.