YORK YC2D LX Central Air Conditioner | 4 Tons - 48000 BTU - R410A

In stock

The 4-ton York YC2D condensing unit: the outdoor half of an R-410A central air conditioner, matched with a coil or a fan coil.

Model numberYC2D48SB21S

4 tons48,000 BTU/h nominal size
13.4 to 14.5SEER2 depending on the matched indoor unit
76 dBAsound power
R-410ACooling only208/230 V · single phase45 A max. breaker
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberYC2D48SB21S
ManufacturerYork
SeriesYC2D LX
Size4 tons (48,000 BTU/h)
RefrigerantR-410A
SEER2 range13.4 to 14.5, depending on match
Minimum circuit ampacity25.7 A

4 tons for multi-storey houses and large open-plan spaces

A 4-ton size, or 48,000 BTU/h: the YC2D48SB21S belongs to the York YC2D (LX) series, between the 3.5-ton and 5-ton sizes of the same series. This R-410A condensing unit uses a single-stage scroll compressor. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.

The YC2D belongs to York's LX range, here in R-410A and on clearance. It is the range's basic model, rated 13.4 SEER2 by York, with a single-stage compressor (rotary at 1.5 and 2 tons, scroll in the other sizes), G90-equivalent steel and a powder coat tested in salt spray to ASTM B117 (at least 500 h). The limited warranty is 10 years on the compressor, and the parts warranty goes from 5 to 10 years with registration.

The right size for your home

This size targets large multi-storey houses, open-plan layouts and heavily glazed homes, where a smaller unit struggles to keep the top floor comfortable. We always check the furnace airflow and the size of the return ducts before recommending this size.

What the manufacturer's spec sheet says

York publishes a range of 13.4 to 14.5 SEER2 for this size, depending on the matched indoor section; the condensing unit alone has no certified rating. The spec sheet lists a sound power of 76 dBA. It needs a 208/230 V single-phase circuit with a 25.7 A minimum circuit ampacity and a 45 A maximum time-delay fuse or breaker.

The unit ships with a factory charge of 4.69 lb (2.13 kg) of R-410A, which our technicians adjust to the actual piping length. The cabinet measures 35 1/4 x 31 3/4 in at the base and 33 1/4 in high, with an operating weight of 200 lb, 5 lb more than the 3.5-ton size. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).

Manufacturers are gradually replacing R-410A with R-454B and R-32 in their new series, so this model is offered until stock runs out. It is most attractive if your current R-410A coil is recent and compatible.

Note: this is a cooling-only unit, not eligible for LogisVert when sold alone. If heating interests you too, ask us for the price of an equivalent central heat pump.

Other York series offered at 4 tons: York YCE LX, York YCG LX, York YC2E LX.

How the installation goes

Our technicians do all the work themselves, from refrigeration to electrical: AirGreen holds RBQ licence 5645-9605-01 and has been installing in Montreal for more than fifteen years.

  1. Free on-site estimate and size validation;
  2. Written quote that specifies the matched indoor section and the electrical circuit;
  3. Setting the outdoor unit on a stable base and installing the indoor section;
  4. Refrigerant piping with a 7/8 in vapor valve, evacuation and charge adjustment;
  5. Electrical connection, commissioning and airflow check at the grilles.

The manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We install throughout Greater Montreal: Montreal, Laval, Longueuil, the North Shore and the South Shore.

Get a quote

Send us a free estimate request for the YC2D48SB21S: we validate the size on site and give you a written price, installation included. Financing is available.

01 · What it is for

The outdoor half of a 4-ton central air system

The YC2D48SB21S sits outside and rejects the heat removed from the house. Indoors it needs a matched section: a coil on top of an electric furnace, or a fan coil.

  • Large multi-storey houses cooled through a single duct system
  • Open-plan and heavily glazed houses
  • Replacing a central air conditioner of the same size
  • Large-capacity electric furnace or fan coil
13.4 to 14.5 SEER2The range York publishes for the 4-ton size, depending on the matched indoor unit.
25.7 A circuitPublished minimum circuit ampacity, with a 45 A maximum time-delay fuse or breaker.
Up to 80 ft of pipingMaximum equivalent length allowed by the manufacturer, so the unit can go where it bothers least.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerYork
SeriesYC2D (LX)
TypeSplit central air conditioner outdoor unit, cooling only
Nominal size4 tons (48,000 BTU/h)
RefrigerantR-410A
CompressorScroll, single stage
Efficiency (manufacturer range)13.4 to 14.5 SEER2 depending on the matched indoor unit
Sound power76 dBA
Power supply208/230 V, single phase, 60 Hz (187 to 252 V operating)
Minimum circuit ampacity25.7 A
Max. time-delay fuse or breaker45 A
Compressor (RLA / LRA)19.5 A / 130.0 A
Fan motor (FLA)1.3 A
Liquid valve3/8 in
Vapor valve7/8 in
Factory charge4.69 lb (2.13 kg) of R-410A for 15 ft of piping
Piping lengthUp to 80 ft (24.4 m) equivalent
Low-ambient cooling55°F (12.8°C) without accessories; down to 20°F (-7°C) with the approved low-ambient kits
Dimensions (W x D x H)35 1/4 x 31 3/4 x 33 1/4 in
Operating weight200 lb (90.7 kg)
CabinetG90-equivalent steel, powder-coat paint rated for at least 500 h of salt spray (ASTM B117); top discharge
Model numberYC2D48SB21S
03 · Before installing

What to know before installing

  • Cooling only: the unit does not heat. Sold alone: not eligible for the LogisVert grant.
  • The indoor section (coil or fan coil) is not included: we choose it from the matches the manufacturer publishes.
  • 208/230 V single-phase, 60 Hz circuit: 25.7 A minimum ampacity, 45 A maximum time-delay fuse or breaker.
  • Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient control kit extends it to 20°F (-7°C).
  • R-410A model: its manufacture and import ended in Canada in 2025; offered while our suppliers' stock lasts.
04 · See also

Explore the range

Same category
Central air conditioners
See all
Same brand
YORK
See all
05 · Questions

Frequently asked questions

Are my ducts big enough for 4 tons?

We always check this at this size. Undersized ducts make the air noisy at the grilles and reduce performance; we assess them during the free estimate.

Does this air conditioner heat the house?

No. The YC2D48SB21S is cooling only; heating stays with your electric furnace or current system. Sold alone, it is not eligible for the LogisVert grant.

What indoor equipment does it work with?

A cooling coil on top of an electric furnace, or a fan coil. We confirm the match before ordering.

What efficiency can I expect?

York publishes 13.4 to 14.5 SEER2 for this size. The outdoor unit alone has no certified rating: the value depends on the matched indoor section.

What electrical circuit is needed?

A 208/230 V single-phase circuit with a 25.7 A minimum ampacity and a 45 A maximum time-delay fuse or breaker, according to the manufacturer's spec sheet. We check your panel's capacity before the quote.

What warranty does the manufacturer offer?

According to the manufacturer's spec sheet: 5-year limited parts warranty and 10-year limited compressor warranty. The parts warranty extends to 10 years if the unit is registered online within 90 days of purchase (replacement) or closing (new construction). It does not apply to Internet sales.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 4-ton central air conditioner, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.