KINGHOME Multi-Zone R32 Floor Console | 12,000 BTU
The console for the primary bedroom, the corner office and the four-season sunroom
The 12,000 BTU size of the KINGHOME floor console is meant for rooms that need a little more than a small bedroom: the primary bedroom with two exterior walls, the home office in a corner of the house, the family room of a bungalow, or the four-season sunroom added onto the back of a house in Laval or on the South Shore. These rooms often have something in common: large windows, low walls under the windows, and electric baseboards that struggle to keep up in January.
Like every head in the KINGHOME multi-zone lineup, this console doesn't work on its own. It connects to an Ultra Heat multi-zone heat pump outdoor unit, which supplies it with R-32 refrigerant and electrical power. So it has no SEER2 or HSPF2 rating of its own: the certified performance is shown on the outdoor unit's sheet, for the complete system.
What the console format changes in a room full of windows
A sunroom or a bedroom with a lot of glass loses its heat through the windows. Air cooled against the glass sinks and forms a layer of cold air along the floor. A wall-mounted head installed up high warms the top of the room first; the console, set under the window, tackles that cold layer right where it forms. You feel the difference at your feet, which matters in a room where you spend your evenings.
In summer, the same location works the other way. A sunroom facing south or west builds up a lot of heat late in the day. The console blows cool air upward, along the glass, and limits the radiant heat you feel near a large sunny window.
Specs for the 12,000 BTU console
- Nominal capacity: 12,000 BTU, R-32 refrigerant
- Maximum airflow: 441 CFM
- Indoor sound level: 29 to 45 dB(A)
- Dehumidification: 2.96 pt/h, or about 1.4 L/h
- Dimensions: 27.56 x 8.46 x 23.62 inches (width x depth x height)
- 220 V power supplied by the outdoor unit
- Wi-Fi: included
The cabinet is identical to the 9,000 BTU model's. What changes is the airflow, which goes up to 441 CFM, and the dehumidification capacity, which reaches 2.96 pt/h. That second figure is often the most useful one in summer: a sunroom or a primary bedroom with an ensuite bathroom builds up humidity, and a console that removes it efficiently makes the room more comfortable at the same temperature. At low speed, the unit stays at 29 dB(A), the same level as the smallest size.
When to choose the 12,000 over the 9,000 or the 18,000
We don't choose a capacity based on floor area alone. A well-insulated, north-facing primary bedroom can do just fine with the 9,000 BTU. The 12,000 BTU becomes the right choice when the room combines several factors: two exterior walls, a lot of glass, a ceiling higher than average, or a floor over a crawl space or a garage. A four-season sunroom almost always combines these factors.
On the other hand, we avoid going up to the 18,000 BTU just to be safe. A console that's too strong for the room runs in short cycles, dehumidifies poorly and wears out its components faster. The on-site assessment of heating needs that we do room by room is there precisely to avoid both mistakes.
Compatibility with Ultra Heat outdoor units
According to the compatibility table in the KINGHOME multi-zone brochure, the 12,000 BTU heads connect to every outdoor unit in the lineup:
- KM18X6O, up to 2 zones: a console in the primary bedroom and a head in the living room of a condo
- KM24X6O, up to 3 zones: a full floor of a bungalow
- KM30X6O and KM36X6O, up to 4 zones: a single-family house where the baseboards are being replaced
- KM42X6O and KM48X6O, up to 5 zones, then KM60X6O, up to 6 zones: large houses
The KM18X6O to KM48X6O units carry the ENERGY STAR cold climate designation; the KM60X6O does not. The choice of outdoor unit depends on all the rooms to be served, not on the console alone. We add up the needs of each zone, then choose the outdoor unit whose cold-weather capacity covers the house.
Built-in features
The manufacturer's spec sheet lists built-in Wi-Fi for remote control, the I-feel function that measures the temperature at the remote, self-cleaning, forced defrost, soft start and low-voltage start-up. The maintenance heating mode keeps a sunroom above freezing during the weeks it isn't being used. The infrared remote is included and a wired wall controller is available as an option.
What we check before the installation
In Montréal, in Longueuil, on the North Shore as on the South Shore, our assessments follow the same approach, adapted to the console.
The electrical circuit
The console gets its 220 V power from the outdoor unit. So there's no circuit to add for it; it's the minimum circuit ampacity (MCA) and maximum overcurrent protection (MOP) of the selected outdoor unit that set the breaker in the panel. We read those values on that unit's spec sheet and check the capacity of the electrical service. When the console replaces baseboards, the electric heating load goes down, which often leaves some room in the panel.
The outdoor unit
It's installed on a wall bracket or a raised base, above the accumulated snow, with enough clearance for defrost water to drain. For a sunroom, we avoid placing the outdoor unit under a roof overhang that dumps melting snow.
The piping
The diameters are the ones on the manufacturer's spec sheet for this head. The total length of all the lines in the system has to stay within the limits of the chosen outdoor unit. In a sunroom built on piles or on a slab, we plan the route so the lines stay insulated and protected.
The drain
The condensate comes out at the bottom of the console. It needs a continuous slope to the outside or to a drain, or a condensate pump when a slope isn't possible. In a sunroom, we make sure the outdoor outlet won't freeze and won't drain onto a deck.
The room layout
The console needs a clear air intake at its base and an unobstructed outlet above it. An armchair pushed up against it or a shelf above it reduces its performance. We go over this with you before setting the location.
LogisVert assistance
The console doesn't appear on the Hydro-Québec list by itself, since it has no certification of its own. The indicative LogisVert amount is calculated for the complete system, Ultra Heat outdoor unit and heads, using the LogisVert rule ($120 per 1,000 BTU/h of certified heating capacity at -8.3 °C, or $50 with the KM60X6O, which has no cold climate designation); eligibility is confirmed on the installation date. The amount shown on an outdoor unit's page corresponds to the certification with wall-mounted heads: we check that your combination is on the list before giving you the quote. Only Hydro-Québec confirms the assistance granted.
Why go with AirGreen
- Salaried refrigeration technicians, no subcontracting.
- Civil liability insurance of $5,000,000.
- Kinghome warranty registration handled by us, at commissioning.
- After-sales service that knows your system.
Ask for your free estimate: we assess each room, recommend the right Ultra Heat outdoor unit and give you a detailed quote.
Documentation
Warranty: 12 years on the compressor, 12 years on parts and 6 years on labour, directly from the distributor.
