Clean Comfort DV090 Dehumidifier | Installation in Montreal, Laval, Longueuil, South Shore and North Shore
Is it the right size for your home?
It removes 90 pints a day according to the spec sheet. Choose your home's living area, then what you see in the basement.
Living area
What you see in the basement
It's the right size.
For a 2,200 to 2,800 sq ft home with condensation on the walls or windows, you need to remove about 102 pints a day (spec sheet conditions). It removes 90: enough for the house, with some reserve for humid weeks in July.
Calculation: pints a day needed for the living area and the basement's condition, at the spec sheet's test conditions. Our estimator measures the humidity on site before ordering.
What it does, in numbers
$100
Electricity per year
8 h of running a day, May to October
Same calculation for every line: wattage × running hours × 184 days (May to October) × 11.142 ¢/kWh. The unit stops on its own once the target humidity is reached, so its running hours depend on your basement.
Capacities, efficiency and electrical data: manufacturer's spec sheet. Running wattage calculated: litres per day ÷ litres per kWh ÷ 24 h. Cost: Hydro-Québec Rate D, second tier (11.142 ¢/kWh), in effect since April 1, 2026.
What you should know about this one
Published, verifiable facts, not brochure claims.
ExternalA humidity control to plan for
Unlike the DV065, the spec sheet lists no built-in control. Clean Comfort recommends the DV6062A1001 humidity control, sold separately; the sheet adds that it also works with a thermostat that has humidity control.
6 inIt can ventilate too
The spec sheet states that it provides ventilation. Its 6 in. fresh-air inlet lets the fan bring outdoor air into the house on top of dehumidifying.
320 cfmAirflow that holds up with ducts
The spec sheet gives 320 cfm with no ducts, 280 cfm at 0.2 in., 260 cfm at 0.4 in. and 215 cfm at 0.6 in. of static pressure.
E-coatElectrocoated coil
The coil is electrocoated. According to Clean Comfort, this reduces corrosion and helps prevent refrigerant leaks.
90 → 47What it really removes in a basement
90 pints a day at 80 °F, 65 at 70 °F and 47 at 60 °F, always at 60% humidity: those are the numbers on the manufacturer's spec sheet. The cooler the air, the less it removes.
2.9 LWhat it removes per kWh
Each kilowatt-hour removes 2.9 litres of water from the air. At Hydro-Québec's Rate D, that's about 3.8 ¢ per litre.
1 °CIt works in a cold basement
Operating range of 1.1 to 57.2 °C around the unit, per the spec sheet: it keeps working in spring and fall, when the basement is still cool and damp.
MERV 11The filter
Filter: MERV 11, 14 × 17.5 × 1.75 in. It protects the coil and captures part of the particles in the basement air.
6 yrsThe parts warranty
Manufacturer's limited warranty on parts: up to 6 years in an owner-occupied home, 1 year in other cases. It ends if the unit is moved (06/2022 warranty certificate).
What it needs on site
In a finished basement, we put it in the mechanical room and connect it with ducts to keep the noise away from living spaces. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Capacity at 80 °F · 60% RH
- 90 pints/day (42.6 L)
- Capacity at 70 °F · 60% RH
- 65 pints/day
- Capacity at 60 °F · 60% RH
- 47 pints/day
- Energy efficiency
- 2.9 L/kWh
- Power supply
- 120 V · 5.3 A
- Running wattage (calculated)
- ≈ 612 W
- Airflow (0 in. w.g.)
- 320 cfm
- Ducts
- 10 in inlet and outlet · 6 in fresh air
- Filter
- MERV 11, 14 × 17.5 × 1.75 in
- Operating range
- 1.1 to 57.2 °C around the unit
- Weight
- 86 lb
- Warranty
- Up to 6 years on parts
Capacities, efficiency, power supply, airflow, ducts, filter, operating range and weight: manufacturer's spec sheet. Running wattage calculated: 42.6 L per day ÷ 2.9 L/kWh ÷ 24 h. Costs: Hydro-Québec Rate D, second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
We measure the humidity on site, check the drain and the duct route, and give you an installed price.
Clean Comfort DV090: 90 pints a day, with a fresh-air inlet
The DV090 removes 90 pints of water a day at 80 °F and 60% humidity, 65 pints at 70 °F and 47 pints at 60 °F, per Clean Comfort's spec sheet. Each kilowatt-hour removes 2.9 litres of water.
It dehumidifies and ventilates
On top of its 10 in. ducts, it has a 6 in. fresh-air inlet: the spec sheet states that it provides ventilation to the indoor space. It has no built-in control; Clean Comfort recommends the DV6062A1001 humidity control, sold separately, and it also works with a thermostat that handles humidity.
What it needs on site
A 120 V outlet (5.3 A), the ducts, a drain on the ¾ in. female NPT fitting and access to the front panel for maintenance. The installation guide places it indoors, in a space protected from rain and flooding. The unit weighs 86 lb.
The warranty
Up to 6 years on parts in an owner-occupied home, 1 year in other cases, under Clean Comfort's 06/2022 warranty certificate. It ends if the unit is moved from where it was first installed.
In-home estimate
No installed price without seeing the house. Our estimator checks the location, the ducts, the drain and the electrical outlet, then we give you a price. Service in Montréal, Laval, Longueuil, the South Shore and the North Shore. Call 514 316-2973.