Broan EDGE ERV BLP120E80NS-PC Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore
Is it the right size for your home?
It delivers 112 cfm net. Choose your home's living area.
It's the right size.
For a 1,500 to 2,500 sq ft home, about 105 cfm of air needs to be renewed continuously. This unit delivers 112 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.
What it does, in numbers
$27.33
Electricity per year
Less than a 60 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Meets the Québec Construction Code for Greater Montréal. The Code requires 55% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that; 54% is still accepted for work started before October 17, 2027. This unit is rated at 55% at 49 cfm.
Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 28 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
6 ftPlug-in: 6-ft power cord supplied
This PC version comes with a 6-ft cord, so it only needs a nearby 120 V outlet rather than a hardwired connection. For hardwiring, the maker points to the BLP120E80NS-HW.
MirrorMirror configuration with a simple switch
As on all three Broan EDGE units, a built-in selector (patent pending) swaps the airflow configuration, so there is no need to order a different model for mirrored floor plans. The selector must point toward the exterior ducts.
55%What it still recovers at −25 °C
The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 49 cfm.
ExhaustIt defrosts by pausing the fresh air for a few minutes
In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.
ERVIt moves moisture too, not just heat
An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.
2005430Its HVI certification number
Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.
−13 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 125 to 112 cfm. Most spec sheets show only the first number, precisely because it looks better.
28 WMeasured at the airflow it actually runs at
Its 80% at 0 °C is certified at 49 cfm, the continuous airflow of a typical home. At that setting it draws 28 W, or about 245 kWh a year.
5 yearsThe core warranty
The core does the work and is the most expensive part to replace. Motors and parts: 5 years.
4 inWhat it needs on site
4 in ducts, side connection. It weighs 34 lb, and it needs enough clearance to slide the core out once a year.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 125 cfm
- Net airflow at 0.4 in. w.g.
- 112 cfm
- SRE at 0 °C (49 cfm)
- 80%
- SRE at −25 °C (49 cfm)
- 55%
- ASE at 0 °C
- 83%
- Power draw
- 28 W
- Efficacy
- 1.7 cfm/W
- Type
- ERV
- Connection
- Side ports
- Duct collars
- 4 in
- Defrost cycle
- Exhaust only (supply fan off)
- Filters
- Washable filters included (20 PPI); optional 1-in disposable MERV 13 fresh-air filter (V27000)
- Dimensions (L × D × H)
- 28.13 × 18.63 × 9.88 in
- Weight
- 34 lb
- Power supply
- 120 V
- HVI certification (Section III)
- 2005430
- Warranty — core
- 5 years
- Warranty — motors
- 5 years
- Warranty — parts
- 5 years
- Spec sheet (English)
Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005430). Annual consumption calculated at 28 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
On site, we set the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
The EDGE ERV that plugs in
A nearby 120 V outlet is all it takes to power the Broan EDGE BLP120E80NS-PC, since it comes with a 6-ft cord. When you’re replacing an old air exchanger that plugged into an outlet, it’s often the simplest route, with no electrical work. This energy recovery ventilator (ERV) gives a net airflow of 125 cfm at 0.2 in. and 112 cfm at 0.4 in.
The airflow to aim for can’t be guessed from the size of the house: it is set on site, room by room, following CSA F326.
The EDGE line’s mirror selector
Like the other two EDGE units, it has a built-in selector, patent pending, that swaps the airflow configuration. No need to order a different model for a mirrored unit: the same ventilator adapts to whichever side the ducts come from. Just one rule to remember: the selector must point toward the exterior ducts.
Performance
On the numbers, sensible recovery efficiency reaches 80% at 0 °C per HVI, at the 49 cfm test airflow, and the manufacturer’s spec sheet shows 55% at −25 °C at the same airflow. The polymer counterflow core, which also transfers moisture, is washable. This model is not on NRCan’s ENERGY STAR list. Exhaust defrost starts on its own, based on the condition of the core.
VIRTUO, on all three EDGE units
VIRTUO technology, shared by all three EDGE units, drives the two ECM motors and takes 120 readings per minute to hold the airflow you choose, with no manual balancing. The LCD screen lets you adjust that airflow in 1 cfm steps.
On site
The 4 in. ports connect on the side, and no condensate drain is needed. If the ducts connect to a central forced-air system, a fresh-air damper is required: for this model, the VBACKDRAFT4 magnetic backdraft dampers are bought separately.
Filters
The included washable filters (20 PPI) are cleaned every 3 months through two built-in access doors, without opening the unit. For the fresh air, an optional 1-in. disposable MERV 13 filter (V27000) is available.
Construction
The core has impact-resistant plastic covers, and both the cabinet and the door are corrosion-resistant galvanized steel.
Choosing between the PC, HW and 130 versions
With no outlet nearby, or if the job calls for a permanent connection, the BLP120E80NS-HW is the same unit in a hardwired version. If the requirement set under CSA F326 calls for a little more air, or your duct system is 5 in., the BLP130E80NS-PC is the next step up: 121 cfm at 0.4 in., with its backdraft dampers included.
Installed by AirGreen across Greater Montreal
We start from the ventilation requirement worked out room by room following CSA F326. On site, we check the outlet, which side the exterior ducts are on so we can set the selector and, if there’s a furnace, the connection to the return and the backdraft damper. The airflow we settle on is then programmed on the screen and checked on both air streams.
Specifications
- Type: ERV (energy recovery ventilator), Broan EDGE, power-cord version
- ENERGY STAR (Canada): No
- Net airflow: 125 cfm at 0.2 in.; 112 cfm at 0.4 in.
- Sensible recovery efficiency: 80% at 0 °C at 49 cfm (HVI); 55% at −25 °C at 49 cfm (manufacturer’s spec sheet)
- Voltage: 120 V, 60 Hz
- Power supply: 6-ft cord supplied
- Dimensions (W × D × H): 28.13 × 18.63 × 9.88 in.
- Weight: 34 lb
- Ducts: 4 in.
- Connection: side, mirror configuration via built-in selector
- Drain: not required
- Defrost: automatic, exhaust defrost
- Filters: washable filters included (20 PPI); optional 1-in. disposable MERV 13 fresh-air filter (V27000)
- Backdraft dampers: magnetic, optional (VBACKDRAFT4, set of 2)
- HVI certification (Section III): No. 2005430
- Manufacturer’s warranty: according to Broan, 5 years on the core and 5 years on parts.
Sold and installed by AirGreen.
We install in Montreal, Laval, Longueuil, the North Shore and the South Shore. For a quote, call 514 316-2973 or write to sales@airgreen.ca.