Broan-NuTone ERV ERVS100S-PC Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore
Is it the right size for your home?
It delivers 104 cfm net. Choose your home's living area.
It's the right size.
For a 900 to 1,500 sq ft home, about 63 cfm of air needs to be renewed continuously. This unit delivers 104 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.
What it does, in numbers
Airflow and efficiency: manufacturer's published data.
What you should know about this one
Published, verifiable facts, not brochure claims.
RH sensorHumidity sensor limits overly humid outdoor air
A built-in humidity and temperature sensor limits ventilation when outdoor air is very humid. Its limit has three positions (−, N, +) or can be turned off, depending on local conditions.
TimerCan replace up to 2 bathroom fans
The maker states this unit can replace up to two bathroom fans; a 20-minute push-button timer (VB20W, not included) is then installed in each bathroom to switch it to high speed.
ERVIt moves moisture too, not just heat
An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.
−8 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 112 to 104 cfm. Most spec sheets show only the first number, precisely because it looks better.
5 yearsThe core warranty
The core does the work and is the most expensive part to replace. Motors and parts: 5 years.
6 inWhat it needs on site
6 in ducts, side connection. It needs enough clearance to slide the core out once a year.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 112 cfm
- Net airflow at 0.4 in. w.g.
- 104 cfm
- SRE at 0 °C
- 66%
- ASE at 0 °C
- 68%
- Type
- ERV
- Connection
- Side ports
- Duct collars
- 6 in
- Filters
- 2 washable filters (20 PPI) on the core; optional MERV 8 filters (V21030)
- Dimensions (L × D × H)
- 25.69 × 20 × 9.13 in
- Power supply
- 120 V
- Warranty — core
- 5 years
- Warranty — motors
- 5 years
- Warranty — parts
- 5 years
Airflow and efficiency: manufacturer's published data. The manufacturer doesn't publish an efficiency at −25 °C for this model; we don't make one up.
Talk to an HVAC technician before you choose
On site, we set the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
When outdoor air is very humid, ventilation on the ERVS100S-PC is limited automatically: a built-in humidity and temperature sensor holds back the fresh-air intake rather than letting that moisture into the house. It is a small ERV (energy recovery ventilator) rated at 112 cfm at 0.2 in and 104 cfm at 0.4 in, in a cabinet 9.13 in thick with side ports.
A sensor set for your area
The sensor limit has three positions (−, N, +) or can be turned off (OFF). The right choice depends on local conditions: we set it at commissioning, based on the house and its surroundings.
Up to two fewer bathroom fans
The maker states that the ERVS100S-PC can replace up to two bathroom fans. In that case, a 20-minute push-button timer (VB20W, not included) goes in each bathroom and switches the unit to high speed for the length of a shower. One unit then handles both general ventilation and the bathrooms.
Where it sits in the Broan-NuTone lineup
At 112 cfm at 0.2 in, it sits below the Broan EDGE and Broan ONE. It has no HVI file: its figures come from the maker’s spec sheet 1110435E, which states a sensible recovery efficiency of 66% at 64 cfm and 0 °C, drawing 46 W, figures that are not HVI-certified. If a project requires an HVI-certified unit in a comparable flat format, the Broan EDGE BLP120E80NS-PC is the closest option: 125 cfm at 0.2 in, a 9.88 in thick cabinet, 4-in ducts. For more airflow, the Broan ONE BLP150 goes up to 155 cfm at 0.2 in.
What to plan on site
- A location in conditioned space where the temperature stays between 10 and 57 °C: not in an attic or a cold garage.
- A 120 V power supply.
- 6-in ducts, connected on the sides.
- One VB20W timer per bathroom if the unit replaces existing fans.
- The two washable filters (20 PPI) sit on the core; MERV 8 filters are available as an option (V21030).
- Airflows set on site, room by room, following CSA F326.
Specifications
- Type: compact ERV (energy recovery ventilator)
- ENERGY STAR (Canada): No
- Net airflow: 112 cfm at 0.2 in; 104 cfm at 0.4 in
- Sensible recovery efficiency: 66% at 64 cfm and 0 °C, 46 W (spec sheet 1110435E, not HVI-certified)
- Voltage: 120 V, 60 Hz
- Dimensions (W × D × H): 25.69 × 20 × 9.13 in
- Weight: 32 lb
- Ducts: 6 in
- Connection: side ports
- Sensor: built-in humidity and temperature sensor, limit adjustable to three positions (−, N, +) or off
- Installation: conditioned space, between 10 and 57 °C
- Filters: 2 washable filters (20 PPI) on the core; optional MERV 8 filters (V21030)
- Manufacturer’s limited warranty: 5 years on parts only; core covered for 5 years with the original proof of purchase. Residential use only.
Sold and installed by AirGreen.
We install in Montreal, Laval, Longueuil, the North Shore and the South Shore. For a quote, call us at 514 316-2973 or write to sales@airgreen.ca.