Broan-NuTone HV15 Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore
Is it the right size for your home?
It delivers 35 cfm net. Choose your home's living area.
A bit small for this home.
For a condo or a home under 900 sq ft, you need about 37 cfm of continuous ventilation, and this unit tops out at 35 cfm.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.
What it does, in numbers
Airflow and efficiency: manufacturer's published data.
What you should know about this one
Published, verifiable facts, not brochure claims.
220 cfmMoves 220 cfm, of which 56 cfm is outdoor air
Per the Broan-NuTone spec sheet, the HV 1.5 moves 220 cfm at 0.2 in, of which only 56 cfm is outdoor air (net airflow); at 0.4 in, it moves 187 cfm for 35 cfm net. The maker describes no recovery core: it is neither an HRV nor an ERV.
CMRCMR wall control included, three modes
The CMR wall control comes with the unit: minimum, maximum and recirculation modes. The HV15 is mainly used to control excess humidity, and Broan-NuTone classifies it as an end-of-series product.
−21 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 56 to 35 cfm. Most spec sheets show only the first number, precisely because it looks better.
6 inWhat it needs on site
6 in ducts, side connection. It weighs 40 lb, and it needs enough clearance for servicing.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 56 cfm
- Net airflow at 0.4 in. w.g.
- 35 cfm
- Connection
- Side ports
- Duct collars
- 6 in
- Filters
- 1 washable mesh filter (aluminum frame)
- Dimensions (L × D × H)
- 23 × 15 × 12.25 in
- Weight
- 40 lb
- Power supply
- 120 V
- Warranty — motors
- 2 years
- Warranty — parts
- 2 years
Airflow and efficiency: manufacturer's published data. The manufacturer doesn't publish an efficiency at −25 °C for this model; we don't make one up.
Talk to an HVAC technician before you choose
On site, we set the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
The HV15 is neither an HRV nor an ERV, and that is the first thing to know before choosing it. It is an air exchanger with no recovery core described by the maker, and its job lies elsewhere. It circulates a lot of air through the house, renews only a small share of it and is mainly used to control excess humidity.
Two airflows not to confuse
On this unit, the air circulated and the fresh air are two different things. According to Broan-NuTone’s spec sheets (90968 and 90969), at 0.2 in of static pressure it circulates 220 cfm, of which 56 cfm is outdoor air, its net airflow. At 0.4 in, it circulates 187 cfm, for a net airflow of 35 cfm. Only the net airflow actually renews the air: that is the figure we compare with the home’s needs, room by room, following CSA F326.
A wall control in the box
The CMR wall control is included. It offers three modes: minimum, maximum and recirculation.
Who it makes sense for
The HV15 is aimed mainly at homes dealing with excess humidity. Broan-NuTone classifies it as an end-of-series product, so we check availability at quote time.
If you want to recover heat
For a home that needs to ventilate all winter while warming the fresh air with heat from the exhaust air, that is an HRV’s job. With side ports like the HV15, the V160H75RS from the AI Series delivers 159 cfm at 0.2 in and 150 cfm at 0.4 in, with a sensible recovery efficiency of 82% at 36 cfm and 0 °C (HVI). It does, however, require a drain, to plan from the start.
What to plan on site
- Room for a 23 × 15 × 12.25 in, 40 lb cabinet.
- A 120 V power supply.
- Ports in two sizes, connected on the sides: 6 in for the stale-air intake and the fresh-air distribution, 4 or 5 in for the fresh air and the stale-air distribution, with 5-in adapters included.
- A washable mesh filter with an aluminum frame, to keep clean.
- An on-site check, following CSA F326, that the net outdoor airflow is enough for the home.
Specifications
- Type: air exchanger with no recovery core described by the maker (not an HRV or ERV), for humidity control
- ENERGY STAR (Canada): No
- Net airflow (outdoor air): 56 cfm at 0.2 in; 35 cfm at 0.4 in
- Air circulated: 220 cfm at 0.2 in; 187 cfm at 0.4 in
- Sensible recovery efficiency: no value published by the maker
- Voltage: 120 V, 60 Hz
- Dimensions (W × D × H): 23 × 15 × 12.25 in
- Weight: 40 lb
- Ports: 6 in stale-air intake and fresh-air distribution; 4 or 5 in fresh air and stale-air distribution (5-in adapters included)
- Connection: side ports
- Control: CMR wall control included (minimum, maximum, recirculation)
- Filters: 1 washable mesh filter (aluminum frame)
- Status: end-of-series product (Broan-NuTone)
- Manufacturer’s warranty: 2 years on all parts and labour, in workshop only (Broan-NuTone spec sheet).
Sold and installed by AirGreen.
We install in Montreal, Laval, Longueuil, the North Shore and the South Shore. For a quote, call us at 514 316-2973 or write to sales@airgreen.ca.