Broan-NuTone HRV V150H75NS Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore
Is it the right size for your home?
It delivers 140 cfm net. Choose your home's living area.
It's the right size.
For a 1,500 to 2,500 sq ft home, about 105 cfm of air needs to be renewed continuously. This unit delivers 140 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.
What it does, in numbers
$17.57
Electricity per year
Less than a 60 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Meets the Québec Construction Code everywhere in the province. The Code requires 55% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that; 54% is still accepted for work started before October 17, 2027. This unit is rated at 63% at 64 cfm.
Airflow and efficiency at 0 °C: HVI directory, Section III. Efficiency at −25 °C: NRCan ENERGY STAR list. Cost: 18 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
19.13 inSide-port version, 19.13 in high
The four 5-in ports exit on the sides, so this HRV is only 19.13 in high (21.5 in for the top-port V150H75NT). It slips more easily under a beam or existing ductwork.
WashableHRV core washable in soapy water
The polypropylene core slides out and can be washed: at maintenance, following the maker's guide, soak it in cold or lukewarm water with mild soap, rinse it and let it dry. This core maintenance is a condition of the warranty.
63%What it still recovers at −25 °C
The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 64 cfm.
ExhaustIt defrosts by pausing the fresh air for a few minutes
In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.
HRVIt recovers heat, not moisture
Excess moisture leaves the house. The core transfers heat only.
2505429Its HVI certification number
Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.
−10 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 150 to 140 cfm. Most spec sheets show only the first number, precisely because it looks better.
18 WMeasured at the airflow it actually runs at
Its 82% at 0 °C is certified at 36 cfm, the continuous airflow of a typical home. At that setting it draws 18 W, or about 158 kWh a year.
10 yearsThe core warranty
The core does the work and is the most expensive part to replace. Motors and parts: 5 years.
5 inWhat it needs on site
5 in ducts, side connection and a condensate drain. It weighs 35 lb, and it needs enough clearance to slide the core out once a year.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 150 cfm
- Net airflow at 0.4 in. w.g.
- 140 cfm
- SRE at 0 °C (36 cfm)
- 82%
- SRE at −25 °C (64 cfm)
- 63%
- ASE at 0 °C
- 88%
- Power draw
- 18 W
- Efficacy
- 2.0 cfm/W
- Type
- HRV
- Connection
- Side ports
- Duct collars
- 5 in
- Condensate drain
- Required
- Defrost cycle
- Exhaust only (supply fan off)
- Filters
- Washable MERV 8 filter included; optional disposable MERV 13 filter (V242851) or HEPA-type media filter (V25000)
- Dimensions (L × D × H)
- 23.38 × 16.13 × 19.13 in
- Weight
- 35 lb
- Power supply
- 120 V
- HVI certification (Section III)
- 2505429
- Warranty — core
- 10 years
- Warranty — motors
- 5 years
- Warranty — parts
- 5 years
Net airflow, efficiency at 0 °C and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2505429). Efficiency at −25 °C: Natural Resources Canada's ENERGY STAR list, checked November 12, 2026. Annual consumption calculated at 18 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
On site, we set the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
In the AI Series, two HRVs share the low side-port cabinet measuring 23.38 × 16.13 × 19.13 in.: the V150H75NS and the V160H75RS. The first has 5-in. ports, the second 6-in. ports. Same format, same 35 lb weight, but not the same duct diameter or the same way of defrosting. The V150H75NS delivers 150 cfm at 0.2 in. and 140 cfm at 0.4 in. of static pressure.
5 in. or 6 in.: NS or RS
The V160H75RS goes up to 159 cfm at 0.2 in. and uses recirculation defrost, with a motorized damper. The V150H75NS uses exhaust defrost instead: during the cycle, its supply blower shuts down and the exhaust keeps running. Both are on NRCan’s ENERGY STAR list, which gives 63.3% at 63.6 cfm and −25 °C for the V150H75NS and 70.0% at 65 cfm for the V160H75RS. So the choice comes down to three points: the required airflow, the duct diameter and cold-weather performance.
Next to the V150H75NT and the V150E75NS
Compared with its top-port twin, the V150H75NT, the V150H75NS has exactly the same airflow and the same efficiency figures. What changes is the shape: 19.13 in. high instead of 21.5 in., but 23.38 in. wide instead of 21 in. Under a beam or under existing ductwork, that lower height can make the difference. The same low cabinet also comes as an ERV, the V150E75NS, at 138 cfm at 0.2 in. and with no drain; the V150H75NS, like the other HRVs in the AI Series, needs one.
The core, maintained as the guide says
The polypropylene core comes out at maintenance. It is soaked in cold or lukewarm water with mild soap, rinsed and left to dry before it goes back in, following the maker’s guide. That care matters for the warranty: the 5 years on parts apply provided the core is maintained, and the core itself is covered for 10 years.
On the job site
- Clearance: we measure the free space under the beam or existing ducts; the unit is 19.13 in. high and 23.38 in. wide.
- Drain: required, so a drain point close by.
- Airflow: set at commissioning, room by room, following CSA F326.
- Filters: the washable MERV 8 is supplied; a disposable MERV 13 filter (V242851) or a HEPA-type media filter (V25000) is available as an option.
Specifications
- Type: HRV (heat recovery ventilator), Broan-NuTone AI Series
- ENERGY STAR (Canada): Yes, on NRCan’s ENERGY STAR list (checked November 12, 2026)
- Net airflow: 150 cfm at 0.2 in.; 140 cfm at 0.4 in. of static pressure
- Sensible recovery efficiency: 82% at 36 cfm and 0 °C (HVI); 63.3% at 63.6 cfm and −25 °C (NRCan ENERGY STAR list, November 12, 2026)
- Voltage: 120 V, 60 Hz
- Dimensions (W × D × H): 23.38 × 16.13 × 19.13 in.
- Weight: 35 lb
- Ducts: 5 in. diameter
- Connection: side
- Drain: required
- Defrost: exhaust defrost (the supply blower stops, exhaust continues)
- Filters: Washable MERV 8 filter included; optional disposable MERV 13 filter (V242851) or HEPA-type media filter (V25000)
- HVI certification (Section III): No. 2505429
- Manufacturer’s limited warranty, parts only: 5 years on parts, provided the core is maintained; 10 years on the core. Labour and shipping not covered. Residential use; original invoice required.
Sold and installed by AirGreen.
We install in Montreal, Laval, Longueuil, the North Shore and the South Shore. To have a V150H75NS installed, call us at 514 316-2973 or write to sales@airgreen.ca.
