Fantech ERV SER 450 Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore
What you should know about this one
Published, verifiable facts, not brochure claims.
46%46% latent transfer in heating (AHRI 1060)
The brochure gives the SER 450 a heating effectiveness of 63% sensible, 46% latent and 59% total, per AHRI 1060. The SER 700, 1100 and 1300 list 35% latent in heating.
RailsMotors and core mounted on removable sliding rails
The supply and exhaust fan motors and the core are mounted on removable sliding rails for quick access. The door panels are reversible so they can open on the side where service is done.
ExhaustIt defrosts by pausing the fresh air for a few minutes
In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.
ERVIt moves moisture too, not just heat
An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Type
- ERV
- Defrost cycle
- Exhaust only (supply fan off)
- Filters
- MERV 3 filters (exhaust and supply); MERV 8 or MERV 13 upgrade
- Weight
- 132 lb
- Power supply
- 120 V
- Spec sheet (French)
- Spec sheet (English)
The manufacturer doesn't publish an efficiency at −25 °C for this model; we don't make one up.
Talk to an HVAC technician before you choose
We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
Fantech SER 450: the ERV in the series that recovers the most moisture
The Fantech SER 450 is a light commercial energy recovery ventilator (ERV): it recovers heat and part of the moisture from the exhaust air. Fantech's brochure gives it 468 cfm at 0.4 in. It suits offices, clinics, shops and large homes where dry winter air or humid summer air bothers the occupants.
The Fantech SER 450 is not listed in the HVI directory, which rates residential units. It has no certified net airflow to compare with a residential model: instead, we start from the building's ventilation calculation to check that it is suitable.
46% latent transfer in heating
For the SER 450, the brochure gives a heating efficiency of 63% sensible, 46% latent and 59% total, according to the AHRI 1060 standard. In cooling: 63% sensible, 42% latent and 58% total. These percentages are used to compare units with one another; on their own, they do not predict your heating savings. The SER 700, 1100 and 1300 show 35% latent in heating. If keeping moisture in winter matters to you, this is the model in the series with the highest latent transfer.
Motors and core on sliding rails
For maintenance, Fantech mounted the supply and exhaust motors as well as the core on removable sliding rails: they come out of the unit without disassembly. The door panels are reversible, and defrost stops the fresh air fan to protect the core from freezing. Recirculation through a BPM module is only available on the SHR units.
Power consumption
The unit consumes 500 W and draws 4.17 A on 120 V single-phase, or about 0.9 cfm per watt at 0.4 in. according to the brochure. Fantech also offers the ECO-Touch IAQ control, which detects volatile organic compounds and automatically increases airflow when air quality drops.
Installation: weight, and data the brochure does not publish
The SER 450 weighs 132 lb.
For the SER series, we only have Fantech's brochure: it does not publish the dimensions, the location of the connections or the drain requirements. Before setting the location of the Fantech SER 450, we obtain this information from the manufacturer.
Fantech presents the SHR and SER as complete air handling solutions: supply and exhaust fans, filters, core and integrated control system. Their compact footprint makes it possible to fit the SER 450 in a mechanical room where floor space is limited.
ERV or HRV: what makes the difference
In an air-conditioned or heavily occupied space, humidity matters as much as temperature: that is where an ERV makes more sense than an HRV. The enthalpy core limits the moisture that fresh air brings in during the summer. If, on the contrary, your premises produce a lot of moisture in winter, we compare with an SHR from the same series.
Filter maintenance
MERV 3 filters protect both airstreams of the Fantech SER 450. For better filtration of outdoor air, Fantech offers MERV 8 or MERV 13 filters; the MERV 13 captures 50% of particles from 0.3 to 1 micron according to the brochure. A finer filter adds resistance: we take that into account during balancing.
Warranty
The Fantech documents we have do not specify the warranty for the SER series. We send you the manufacturer's terms for the Fantech SER 450 with the quote.
Installation by AirGreen in Greater Montreal
Before proposing the Fantech SER 450, we establish the outdoor airflow your premises need based on the building's ventilation calculation. In a large home, we apply the room-by-room method of the CSA F326 standard. We also check the space, the electrical supply and the duct routing.
The job ends with balancing: we measure fresh air and exhaust air and adjust them to the calculated airflow. That way, you know exactly what your ERV delivers, and we can compare these measurements from one year to the next during maintenance.
We work in Montreal, Laval, Longueuil, the North Shore and the South Shore. For a free quote, call 514 316-2973 or write to sales@airgreen.ca.