Fantech HRV SHR 450 Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore

In stock
SKU: SHR 450
HRV
01 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

SHRSHR code: S for side ducting, R for remote control

According to the Fantech manual, S stands for Side Ducting, H for Heat Recovery and R for the Remote Control Option, the number giving the airflow class at 0.4 in. The SHR 450 sheet gives 465 cfm at high speed at 0.4 in.

BPMRecirculation defrost available with the BPM module

Standard defrost shuts down the supply fan. With the optional BPM bypass module, offered on SHR models only, a motorized damper closes the fresh-air intake so indoor air circulates through the core without creating negative pressure.

ExhaustIt defrosts by pausing the fresh air for a few minutes

In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.

HRVIt recovers heat, not moisture

Excess moisture leaves the house. In Québec, that's the right choice in most cases: in winter, a home almost always has too much humidity, not too little.

LifetimeThe core warranty

The core does the work and is the most expensive part to replace. Motors and parts: 3 years.

02 · Installation

What it needs on site

Side connectionSide ports
Condensate drainRequired
146 lbUnit weight
35.88 × 29.44 × 22.75 inLength × depth × height
120 VPower supply

In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.

Complete spec sheetData and cited sources
Type
HRV
Connection
Side ports
Condensate drain
Required
Defrost cycle
Exhaust only (supply fan off)
Filters
Washable MERV 3 filters (exhaust and supply); MERV 8 or MERV 13 upgrade
Dimensions (L × D × H)
35.88 × 29.44 × 22.75 in
Weight
146 lb
Power supply
120 V
Warranty — core
Lifetime
Warranty — motors
3 years
Warranty — parts
3 years
Spec sheet (French)
PDF
Spec sheet (English)
PDF

The manufacturer doesn't publish an efficiency at −25 °C for this model; we don't make one up.

Talk to an HVAC technician before you choose

We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.

Fantech SHR 450: the starting point of the light commercial series

The Fantech SHR 450 is the smallest heat recovery ventilator in Fantech's SHR series, designed for small businesses, offices, classrooms and large homes. Its sheet gives 465 cfm at high speed at 0.4 in. of static pressure, and 303 cfm at 1.0 in. Fantech highlights the compact size of the series: the unit fits in a mechanical room where floor space is limited.

This is a commercial unit: the Fantech SHR 450 has no HVI rating, so no net airflow or efficiency certified in the residential sense. The ventilation calculation for your premises is what tells us whether it is the right size.

What the SHR code means

According to Fantech's manual, S stands for side connections (Side Ducting), H for heat recovery and R for the remote control option; the number gives the airflow class at 0.4 in. The SHR 450 sheet gives 465 cfm at 0.4 in.; the brochure rounds it to 464 cfm. Side connections make it easier to run ducts through a ceiling space.

Recirculation defrost with the BPM module

Standard defrost shuts off the fresh air fan while the exhaust air defrosts the core. With the optional BPM bypass module, available only on SHR units, a motorized damper closes the fresh air intake as soon as outdoor air reaches −5 °C: indoor air then circulates through the core to warm it, and the unit does not create negative pressure.

Efficiency and power consumption

At 35 °F (1.7 °C), net sensible effectiveness is 56% at 300 cfm and 57% at 225 cfm, according to the data for the AHRI 1060 certified core. The unit uses 470 W and draws 3.92 A on 120 V, or about 1.0 cfm per watt according to the brochure.

Installation: dimensions, weight and drain

The cabinet measures 35.88 × 29.44 × 22.75 in. (L × D × H) and weighs 146 lb. The fan motors and the core are mounted on removable sliding rails, and the door panels are reversible so they open on the side where service is done. A drain is required. Condensate, including during defrost, must flow to a drain or a condensate pump, with a P-trap in the hose to keep odours from coming back up. The unit and its condensate hoses must be located in a heated space, above freezing.

ECO-Touch IAQ control

For this series, Fantech offers the ECO-Touch IAQ control. Its ECO mode selects the mode and speed according to the season, and its total volatile organic compounds sensor raises fresh air and exhaust airflow when the air becomes loaded with cleaning solvents or cooking odours. For the Fantech SHR 450, it is a simple way to ventilate more during busy hours only.

Filter maintenance

The Fantech SHR 450 comes with washable MERV 3 filters on the fresh air and stale air streams. Fantech describes them as starter filters, able to capture about 20% of particles from 3 to 10 microns. A MERV 8 filter captures 70% of those particles and a MERV 13, 95%: that is the upgrade to consider near a busy street.

Fantech's manual calls for checking and cleaning the filters once a month, or sooner if they look dirty. The motors are factory balanced and lubricated for life: they require no maintenance.

Warranty

Fantech warrants the SHR 450 core for life (limited warranty), and the motor and electrical components for 3 years.

Installation by AirGreen in Greater Montreal

We don't sell an HRV at random. For a small business, an office or a classroom, the starting point is the building's ventilation calculation; for a large home, it is the room-by-room calculation called for by the CSA F326 standard. We then compare that airflow with the Fantech SHR 450 curve and with the pressure of your duct system.

At commissioning, we balance both airflows to the calculated rate. That adjustment is what makes a unit actually ventilate what it is supposed to ventilate, without depressurizing the building. We then explain to the person in charge of the premises how to set the speeds and when to clean the filters.

AirGreen serves Montreal, Laval, Longueuil, the North Shore and the South Shore. Free quote: 514 316-2973 or sales@airgreen.ca.