Lifebreath 1500E ECM-240SP HRV Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore
What you should know about this one
Published, verifiable facts, not brochure claims.
EExterior rooftop version, connections under the unit
The 1500E installs on a roof, on an optional curb (53-1500). The two 19 × 16 in connections to and from the building are under the cabinet, and two 18 × 17 in hoods with washable screens are included on the side. The 1500I is the indoor version.
240SPECM-240SP: dual-voltage 208/240 V single-phase ECM motors
The ECM-240SP suffix marks two 1 HP variable-speed ECM motors on a dual-voltage unit fed at 208 or 240 V single phase (MOP 30 A). The sheet gives 1500 cfm at 1.0 in of external static pressure, with three independently adjustable speeds.
ExhaustIt defrosts by pausing the fresh air for a few minutes
In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.
HRVIt recovers heat, not moisture
Excess moisture leaves the house. In Québec, that's the right choice in most cases: in winter, a house almost always has too much humidity, not too little.
15 yearsThe core warranty
The core does the work and is the most expensive part to replace. Motors and parts: 2 years.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Type
- HRV
- Condensate drain
- Required
- Defrost cycle
- Exhaust only (supply fan off)
- Filters
- 4 pleated MERV 8 filters (20 × 16 × 2 in), 2 per airstream
- Dimensions (L × D × H)
- 69.5 × 46.5 × 41 in
- Weight
- 555 lb
- Power supply
- 220 V
- Warranty — core
- 15 years
- Warranty — motors
- 2 years
- Warranty — parts
- 2 years
- Spec sheet (French)
- Spec sheet (English)
The manufacturer doesn't publish an efficiency at −25 °C for this model; we don't make one up.
Talk to an HVAC technician before you choose
We assess your needs on site, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
Lifebreath 1500E ECM-240SP: a rooftop HRV with ECM motors
On a flat roof, the Lifebreath 1500E ECM-240SP frees up the mechanical room: this commercial heat recovery ventilator installs outdoors and connects to the building from underneath. Lifebreath rates it at 1,500 cfm (705 L/s) at 1.0 in. of external static pressure, and its manual states that it leaves the factory set to that point. With that kind of airflow, it is aimed at single-storey buildings where every square metre of indoor space counts: stores, schools, clinics, office buildings.
The HVI directory, which rates residential units, does not include the 1500E ECM-240SP; no HVI-certified net airflow or efficiency puts it side by side with a residential HRV. When it has to ventilate dwelling units, we first check its certification against article 9.36.3.9 of the Québec Construction Code, which requires, for the principal ventilation system of a dwelling, a unit whose efficiency is measured and certified in the ways the Code provides for.
E for Exterior: a Rooftop Unit
The 1500E sits on a roof curb offered as an option (part 53-1500). Its two 19 × 16 in. (482 × 406 mm) connections, one to the building and one from the building, open under the cabinet. The two 18 × 17 in. hoods, with washable screens, go on the side of the unit; according to Lifebreath's manual, they arrive stored inside the cabinet, and there is no wall hood to cut in.
Made of 22-gauge powder-coated steel, the cabinet has a lining of 1 in. (25 mm) of elastomeric insulation. Two powder-coated galvanized steel pans, each fitted with a 1/2 in. (12 mm) OD connection, collect the water: even on a roof, a drain is required.
ECM-240SP: Dual-Voltage ECM Motors
Behind the ECM-240SP suffix are two 1.0 HP single-shaft, variable-speed ECM motors on a dual-voltage unit fed at 208 or 240 V single-phase. At 208 V, the spec sheet gives 20.6 A; at 240 V, 18.2 A, with a maximum overcurrent protection of 30 A in both cases. The minimum circuit ampacity is shown on the unit's nameplate. The manual strongly recommends an electrical disconnect ahead of the HRV. The three speeds are set independently on the ECM board in the electrical box, which lets the unit be matched to the building's actual needs rather than run at its maximum.
Efficiency and Defrost
Six aluminum cores, arranged in cross-flow, recover heat from the exhaust air, and two direct-drive centrifugal blowers, one per airstream, move the air. The spec sheet lists an efficiency of 65% at 1,500 cfm; Lifebreath's commercial sales sheet places it at 0 °C, with no other test condition, and we read it as a ballpark figure. In cold weather, below −3 °C (27 °F) outdoors, the factory-set defrost timer takes over: both motors pause for one minute, then the stale air runs alone for four minutes, with the fresh-air motor off, to melt the frost on the core. Then come 30 minutes of normal operation, or 20 minutes if DIP switch 8 is set to ON.
Installation: Weight, Curb and Clearance
At 555 lb (252 kg), and 675 lb shipping, the 1500E is prepared like any piece of rooftop equipment: structural check, 53-1500 curb and a planned lift. According to the manual, the curb is 1 in. smaller than the cabinet, only its perimeter is insulated, and its slope must not exceed 1/16 in. per linear foot in any direction. Plan for at least 40 in. (1 m) of clearance on one side of the unit for service. A microprocessor board with built-in interlock contacts runs the unit.
The Advantages and Demands of a Rooftop Unit
Set on the roof, the unit keeps duct runs short to the spaces directly below. In return, it needs a roof that can carry it and safe access for service, winter included: we look at both points during the visit. If the roof is not suitable, the 1500I offers the same airflow and the same motors for an indoor installation, in a heated room and with hoods supplied by the contractor. As for approvals, the spec sheet states conformity with CSA and UL standards.
Filter Care
The unit takes four 20 × 16 × 2 in. (508 × 406 × 50 mm) MERV 8 pleated filters, two in each airstream. They are disposable filters: we replace them during maintenance and clean the hood screens at the same time. They are reached through the filter service panel, on one side or both; the cores then slide out of the cabinet for routine maintenance.
Warranty
Lifebreath warrants the core of the 1500E ECM-240SP for 15 years and replacement parts for 2 years. No separate term is published for the motors: they follow the parts warranty.
Installation by AirGreen in Greater Montreal
On every 1500E job, we assess the building's ventilation needs on site, space by space. That picture, set against the curve of the Lifebreath 1500E ECM-240SP and the static pressure of the planned duct system, sets the speed to use.
On the roof, 1/2 in. rigid tubing runs from the two drain spouts to a P-trap built with the plastic tee, below the bottom of the door and sloped 1/4 in. per foot, as the manual requires. At start-up, we use a Pitot tube to balance the two airstreams following Lifebreath's method, then we show the building manager how to change speeds and when to replace the filters.
Ask for a quote at 514 316-2973 or sales@airgreen.ca: we will call you back. AirGreen installs the 1500E in Montreal, Laval, Longueuil, the North Shore and the South Shore, with its team under its RBQ licence 5645-9605-01.