Lifebreath 2000 EFD HRV Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore

In stock
SKU: 2000 EFD
HRV
01 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

EFDE for exterior: rooftop unit with hoods included

The 2000 EFD is designed for outdoor installation on an optional roof curb (53-2007). Two 20 × 19 in hoods with washable screens are included, and the two 25 × 16 in connections to and from the building are under the cabinet. The 2000 IFD is the indoor version.

575 VFive power supplies, from 208 V single-phase to 575 V three-phase

The 2000 EFD comes in 208 or 240 V single phase (SP) and 208, 460 or 575 V three phase (3P), depending on the order code. Its two belt-drive blowers have adjustable pulleys, and the sheet gives 2000 cfm at 1.0 in.

ExhaustIt defrosts by pausing the fresh air for a few minutes

In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.

HRVIt recovers heat, not moisture

Excess moisture leaves the house. In Québec, that's the right choice in most cases: in winter, a house almost always has too much humidity, not too little.

15 yearsThe core warranty

The core does the work and is the most expensive part to replace. Motors and parts: 2 years.

02 · Installation

What it needs on site

Condensate drainRequired
770 lbUnit weight
69.5 × 57.25 × 43 inLength × depth × height
220 VPower supply

In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.

Complete spec sheetData and cited sources
Type
HRV
Condensate drain
Required
Defrost cycle
Exhaust only (supply fan off)
Filters
4 pleated MERV 8 filters (16 × 25 × 2 in), 2 per airstream
Dimensions (L × D × H)
69.5 × 57.25 × 43 in
Weight
770 lb
Power supply
220 V
Warranty — core
15 years
Warranty — motors
2 years
Warranty — parts
2 years
Spec sheet (French)
PDF
Spec sheet (English)
PDF

The manufacturer doesn't publish an efficiency at −25 °C for this model; we don't make one up.

Talk to an HVAC technician before you choose

We assess your needs on site, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.

Lifebreath 2000 EFD: the rooftop HRV for large air volumes

Of the two Lifebreath rooftop HRVs we offer, the Lifebreath 2000 EFD is the large size: this heat recovery ventilator is rated at 2,000 cfm (940 L/s) at an external static pressure of 1.0 in., compared with 1,500 cfm for the 1500E. That volume of air makes it a fit for schools, community centres, big-box stores and office buildings whose roof can take an outdoor unit.

The HVI directory does not list it, like most commercial units: no certified net airflow and no recovery efficiency appear there for it. If the building includes dwelling units, we first make sure that the unit chosen for their principal ventilation system carries the certification that article 9.36.3.9 of the Québec Construction Code requires.

EFD: Exterior, Defrost by Shutting Off the Fresh Air

The E in the code stands for exterior. Its roof curb, part 53-2007, is sold as an option. Its two 25 × 16 in. (635 × 406 mm) connections, to and from the building, open under the cabinet, and its two 20 × 19 in. hoods with washable screens are supplied: according to the manual, they are shipped inside the cabinet. FD refers to the defrost: the fresh-air motor stops while the exhaust air defrosts the core. The cycle starts below −3 °C (27 °F): one minute with everything stopped, four minutes with only the stale air moving, then 30 minutes of normal operation, or 20 if DIP switch 8 is set to ON.

Powder-coated to resist corrosion, the cabinet's 22-gauge steel forms metal-lined sides and roof panels, insulated with 1 in. of fibreglass.

Five Power Supplies, from 208 V Single-Phase to 575 V Three-Phase

Five versions are offered: 208 V and 240 V single-phase, 208 V, 460 V and 575 V three-phase, each under its own order code. The first three use two 2.0 HP ODP motors, while the 460 V and 575 V models get two 1.5 HP TEFC motors. The maximum overcurrent protection depends on the voltage and is shown on the nameplate of the unit ordered. We therefore confirm your building's voltage before placing the order.

Efficiency and Belt-Drive Blowers

Eight aluminum cores, arranged in cross-flow, transfer heat from the outgoing air to the incoming air. Lifebreath credits it with an efficiency of 65% at 2,000 cfm; its commercial sales sheet ties that figure to 0 °C, without giving any other test conditions. The two centrifugal blowers, one per airstream, are belt driven. Each motor carries a variable-pitch pulley that sets its airflow independently; after any pitch change, the manual calls for re-tensioning the belt and taking an amperage reading, which must never exceed the motor's rated value.

Installation: Weight, Drain and Clearance

At 770 lb (349 kg), and 910 lb shipping, this is a rooftop installation that has to be planned: structure, 53-2007 curb and lift. Its two powder-coated galvanized steel drain pans empty through 1/2 in. OD outlets: a drain is mandatory, and the manual wants it trapped and placed below the level of the door, with 1/4 in. of slope per foot away from the unit. For service, set aside at least 40 in. (1 m) of clear space on one side of the unit.

Why Choose a Rooftop Unit

On a single-storey building or a flat-roofed school, the 2000 EFD avoids giving up a room to mechanical equipment and shortens the ducts to the top-floor spaces. It does, however, need a roof that can carry its weight and access for service. If that is not the case, the 2000 IFD, its indoor version, offers the same airflow. The spec sheet declares it compliant with CSA and UL standards. A built-in microprocessor board runs the unit, and the manual describes dry contacts that let an air handler or a furnace be interlocked with the HRV's blowers.

Filter and Belt Care

Four 16 × 25 × 2 in. (406 × 635 × 50 mm) MERV 8 pleated filters, two per airstream, are replaced during maintenance. We also check belt tension and clean the hood screens. To take out a blower, the manual has you remove the service panel, unscrew the two bolts that hold it to its rails, disconnect the motors, then slide it back and lift it out.

Warranty

Lifebreath warrants the core of the 2000 EFD for 15 years and replacement parts for 2 years. No separate term is published for the motors: they follow the parts warranty.

Installation by AirGreen in Greater Montreal

We assess the building's ventilation needs on site: how the spaces are used, number of occupants and floor area. That picture either confirms the Lifebreath 2000 EFD or points to a neighbouring size in the Lifebreath range.

Once the unit is on its curb, balancing is done with a Pitot tube on the ducts: we adjust the pulleys until the fresh air equals the exhaust air, then we take an amperage reading on each motor, as the manual requires.

Ask for a quote at 514 316-2973 or sales@airgreen.ca: we will call you back. We install in Montreal, Laval, Longueuil, the North Shore and the South Shore, with our team under AirGreen's RBQ licence 5645-9605-01.