Lifebreath 700 FD HRV Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore

In stock
SKU: 700 FD
HRV
01 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

FDFD version: supply shutdown, no fifth port

The FD suffix (Fan Defrost) marks the supply-fan-shutdown version: exhaust air defrosts the core while supply air is interrupted. It lacks the fifth damper port of the 700 DD, which shares the same 33.25 × 29 × 32.25 in cabinet.

700 cfm700 cfm nominal airflow at 0.5 in

The sheet's performance table gives a nominal airflow of 700 cfm at 0.5 in of static pressure, with two aluminum HEX cores. Ducts connect to four rectangular 14 × 8 in openings.

ExhaustIt defrosts by pausing the fresh air for a few minutes

In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.

HRVIt recovers heat, not moisture

Excess moisture leaves the house. In Québec, that's the right choice in most cases: in winter, a house almost always has too much humidity, not too little.

15 yearsThe core warranty

The core does the work and is the most expensive part to replace. Motors and parts: 2 years.

02 · Installation

What it needs on site

Side connectionSide ports
Condensate drainRequired
163 lbUnit weight
33.25 × 29 × 32.25 inLength × depth × height
120 VPower supply

In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.

Complete spec sheetData and cited sources
Type
HRV
Connection
Side ports
Condensate drain
Required
Defrost cycle
Exhaust only (supply fan off)
Filters
Washable MERV 6 filters (exhaust and supply); MERV 13 upgrade (65-195-6R)
Dimensions (L × D × H)
33.25 × 29 × 32.25 in
Weight
163 lb
Power supply
120 V
Warranty — core
15 years
Warranty — motors
2 years
Warranty — parts
2 years
Spec sheet (French)
PDF
Spec sheet (English)
PDF

The manufacturer doesn't publish an efficiency at −25 °C for this model; we don't make one up.

Talk to an HVAC technician before you choose

We assess your needs on site, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.

Lifebreath 700 FD: 700 cfm nominal, four connections, no frills

Four connections, no damper and an actual figure for nominal airflow: the Lifebreath 700 FD is the version of the 700 that defrosts without a fifth port. According to its spec sheet, this commercial HRV delivers 700 cfm (329 L/s) at 0.5 in. of static pressure, which makes it an option for a retail store, a daycare or a professional office.

The 700 FD is not listed in the HVI directory, so it has no certified net airflow or efficiency in the residential sense. For a dwelling's principal ventilation, article 9.36.3.9 of the Québec Construction Code calls for a unit tested to CAN/CSA-C439 and certified by HVI or by another body accredited by the Standards Council of Canada, or tested to ANSI/AHRI-1061 and certified by a body the Code designates; if the project is a large home, we check the unit's certification first.

FD version: fresh air shuts off during defrost

FD stands for Fan Defrost. As soon as the outdoor temperature drops below −3 °C (27 °F), the supply fan stops and the exhaust fan keeps running: the outgoing air is what melts the frost in the core. As set at the factory, the cycle alternates 30 minutes of run time and 4 minutes of defrost; setting DIP switch 8 to ON shortens the interval to 20 minutes, with defrosts still lasting 4 minutes. The 700 DD, built in the same cabinet, adds a fifth damper port that the FD does not have.

The FD therefore has one less duct to install and no motorized damper to maintain. The trade-off: during those minutes of defrost, air keeps leaving without being replaced. In a tight space or where combustion appliances are present, we take this into account before recommending the FD over the DD.

700 cfm at 0.5 in. and two aluminum cores

Lifebreath rates the 700 FD at three speeds and 700 cfm nominal at 0.5 in. Heat passes from one airstream to the other through two modular, patented aluminum cores, arranged for counter-flow and crossed in a single pass. The two centrifugal blowers are rated at 700 cfm free air delivery, and the ducts connect to four rectangular 14 × 8 in. collars (356 × 200 mm).

Efficiency and power use

In the performance table of its spec sheet, Lifebreath lists 59% efficiency at 0 °C, without saying at what airflow it was measured: it is an indication, not an HVI rating. The two 68-222 cores carry AHRI 1060 certification.

Each of the two single-shaft 1/4 HP, 1,450 rpm PSC motors draws 4.5 A, for 9 A in total on high speed and 1,032 W. On 120 V, the spec sheet sets the minimum circuit ampacity (MCA) at 11.3 A and the maximum overcurrent protection (MOP) at 15 A; the manual, for its part, recommends a separate 15 A circuit and advises against using an extension cord.

Installation: dimensions, weight and drain

The cabinet is 33.25 in. wide, 29 in. deep and 32.25 in. high, and weighs 163 lb (213 lb shipping). It sits on support brackets hung from threaded rods; neither is supplied. The drain is mandatory, with two 1/2 in. (12 mm) OD connections. The 22-gauge prepainted G60 galvanized steel gets foil-faced insulation wherever condensation would form on the outside. The front and back doors and the electrical panel, which moves from one side to the other, let you choose the duct direction; allow 30 in. (765 mm) of service clearance.

Controls and access

The three speeds are run by a built-in microprocessor circuit board, whose interlock contacts let you tie the HRV to another piece of building equipment. The blowers, one per airstream, slide out of the cabinet, and Lifebreath presents the unit as field reversible. Motors, cores and nominal airflow are identical to those of the 700 DD: the building, not the capacity, decides between the two versions. Lifebreath states that its units conform to CSA and UL standards.

Filter care

The washable MERV 6 filters, on the fresh air and on the stale air, account for most of the routine maintenance on the Lifebreath 700 FD: the manual calls for washing them in cold water, with a mild detergent. For the cores, the interval depends on how the building is used: sometimes every one or two months, at least every six months. Lifebreath has a MERV 13 version (65-195-6R) for finer filtration of the fresh air.

Warranty

Manufacturer's warranty: 15 years on the 700 FD core and 2 years on replacement parts. Lifebreath does not publish a separate warranty for the motors.

Installation by AirGreen in Greater Montreal

Before proposing a commercial HRV, we assess the building's ventilation needs on site: use and occupancy for commercial premises; bedrooms, bathrooms, kitchen and basement for a home. The Lifebreath 700 FD is only chosen if the required airflow falls within its operating range.

On site, the drain gets a P-trap formed with the plastic tee connector, pointing upward. Trap and tubing stay below the bottom of the door, move away from the unit dropping 1/4 in. per foot and run through a space that does not freeze. Outside, the two hoods stay at least 18 in. (46 cm) above the snow line or the ground, fitted with a bird screen whose mesh is at least 1/4 in. (6.35 mm).

At start-up, the unit runs on high speed while we adjust the fresh air to match the exhaust air, from readings taken in the ducts. Lifebreath also advises keeping a service log for the unit: recording the airflows from the first adjustment gives a point of comparison for later visits.

Our teams work in Montreal, Laval, Longueuil, the South Shore and the North Shore, under AirGreen's RBQ licence 5645-9605-01. Ask for a quote at 514 316-2973 or at sales@airgreen.ca: we will call you back.