SKU: RNC5-TPD
155 cfm net1,800 to 2,900 sq ft61% at −25 °C
Talk to an HVAC technician · 514 316-2973
Meets the Québec CodeLifetime core warranty
01 · Your home

Is it the right size for your home?

It delivers 155 cfm net, enough to ventilate 1,800 to 2,900 sq ft. Choose your home's living area.

It's the right size.

For a 1,500 to 2,500 sq ft home, about 105 cfm of air needs to be renewed continuously. This unit delivers 155 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.

Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. We set the exact airflow during our on-site assessment.

02 · Performance

What it does, in numbers

Heat recovery
61%
At −25 °CCode: 55% or 60% minimum
59%
At 0 °CCertified at 83 cfm
Net airflowThe ducts cost it 19 cfm
0.2 in · test bench174 cfm
0.4 in · with ducts155 cfm

$93.70

Electricity per year

Less than a 100 W light bulb

Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.

96W
Running continuously
841kWh
Per year
3months
Filter cleaning

Meets both thresholds of the Québec Construction Code (art. 9.36.3.9). At −25 °C and at least 22 L/s, the Code (art. 9.36.3.9, in force since April 17, 2025) requires 55% where there are fewer than 6,000 heating degree-days and 60% elsewhere. This unit is rated at 61% at 68 cfm (HVI).

Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 96 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).

03 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

DampersBalancing damper on every oval collar

The 5 in oval collars on top each have a balancing damper, and the measuring ports are on the door, so the installer sets airflow right at the unit.

HooksHangs from supplied S hooks and straps

Four threaded inserts at the corners of the 22.75 × 14 × 17.25 in cabinet take the “S” hooks and hanging straps supplied with the unit.

61%What it still recovers at −25 °C

The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 68 cfm.

DamperIt defrosts with indoor air

In cold weather, a motorized damper closes the outdoor air intake and recirculates indoor air through the core to thaw it. During the cycle, no outdoor air comes in through the unit.

HRVIt recovers heat, not moisture

Excess moisture leaves the house. In Québec, that's the right choice in most cases: in winter, a house almost always has too much humidity, not too little.

2505261Its HVI certification number

Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.

−19 cfmWhat the ducts cost it

Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 174 to 155 cfm. Most spec sheets show only the first number, precisely because it looks better.

96 WMeasured at the airflow it actually runs at

Its 59% at 0 °C is certified at 83 cfm, the continuous airflow of a typical home. At that setting it draws 96 W, or about 841 kWh a year.

LifetimeThe core warranty

The core does the work and is the most expensive part to replace. Motors and parts: 5 years.

5 inWhat it needs on site

5 in (oval) ducts, top connection and a condensate drain. It weighs 51 lb, and it needs enough clearance to slide the core out for cleaning.

04 · Installation

What it needs on site

5 in (oval) ductsCollar diameter
Top connectionTop ports
Condensate drainRequired
51 lbUnit weight
22.75 × 14 × 17.25 inLength × depth × height
120 VPower supply

In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.

Complete spec sheetData and cited sources
Net airflow at 0.2 in. w.g.
174 cfm
Net airflow at 0.4 in. w.g.
155 cfm
SRE at 0 °C (83 cfm)
59%
SRE at −25 °C (68 cfm)
61%
ASE at 0 °C
66%
Power draw
96 W
Efficacy
0.9 cfm/W
Type
HRV
Connection
Top ports
Duct collars
5 in (oval)
Condensate drain
Required
Defrost cycle
Recirculation (motorized damper)
Filters
2 washable MERV 6 filters (exhaust and supply); MERV 13 upgrade (65-192-6R)
Dimensions (L × D × H)
22.75 × 14 × 17.25 in
Weight
51 lb
Power supply
120 V
HVI certification (Section III)
2505261
Warranty — core
Lifetime
Warranty — motors
5 years
Warranty — parts
5 years
Spec sheet (French)
PDF
Spec sheet (English)
PDF

Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2505261). Annual consumption calculated at 96 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.

05 · In the same family

The next model down and up

Talk to an HVAC technician before you choose

We assess your needs on site, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.

155 cfm net in a 22.75 in. cabinet

Short, stocky and generous with air, the Lifebreath RNC5-TPD is a heat recovery ventilator (HRV) that delivers high airflow for its size. Lifebreath presents it as a high-performing unit in a compact format. On its spec sheet, the net airflow is 186 cfm at 0.1 in. of static pressure, 174 cfm at 0.2 in. and 155 cfm at 0.4 in., the value HVI lists; it holds at 127 cfm at 0.7 in.

Recirculating damper defrost

The RNC5-TPD shares its cabinet with the RNC5-TPF; the first difference is the defrost. Here, a recirculating damper, which Lifebreath calls intelligent, makes sure that during the cycle it is indoor air, not outdoor air, that flows through the core. The RNC5-TPF, for its part, shuts off its fresh-air motor at intervals.

The two models also differ in the HVI directory. At 0 °C and 64 cfm, the RNC5-TPD scores 58% for 79 W, against 65% for 68 W for the RNC5-TPF. In deep cold, the edge changes sides: Lifebreath highlights the RNC5-TPD's excellent low-temperature performance, and HVI gives it a higher result at −25 °C than at 0 °C. At −25 °C and 68 cfm, its sensible recovery efficiency is 61% (HVI directory, November 4, 2026 edition). The Québec Construction Code (art. 9.36.3.9) requires at least 55% where there are fewer than 6,000 heating degree-days and 60% elsewhere, at a minimum of 22 L/s. The RNC5-TPD therefore meets both thresholds, while the RNC5-TPF stops at 56% at −25 °C.

A cross-flow core

Its heat-conducting cross-flow core passes heat from one airstream to the other. At 0 °C, HVI rates the unit at 58% at 64 cfm, 59% at 83 cfm and 57% at 114 cfm: a counter-flow HEX core recovers more, but this one keeps the unit short and lets a lot of air through. For cleaning, Lifebreath made it easy to remove.

Energy use

Each of the two airstreams is driven by its own motorized impeller, with several speeds. HVI measures 79 W at 64 cfm, 96 W at 83 cfm, or 0.9 cfm per watt, and 114 W at 114 cfm; at −25 °C and 68 cfm, the unit takes 93 W. Running continuously at the 83 cfm point, that comes to about 841 kWh a year, around $94 at Hydro-Québec Rate D (second tier, 11.142 ¢/kWh). Setting the high speed to the airflow the home actually needs, rather than to the maximum, therefore keeps the bill lower.

Dampers on every collar

On top, each of the four 5 in. oval collars has its own built-in balancing damper, and the airflow readings are taken at the door. The airflows are therefore set right at the unit, with no extra damper in the ducts. The high speed is selected by DIP switch (Hi 3 from the factory).

Hanging and drain

The cabinet measures 22.75 in. long, 14 in. deep and 17.25 in. high, and weighs 51 lb. Its four corners carry threaded inserts that take the supplied straps and “S” hooks. The drain, which is mandatory, connects to two 1/2 in. (12 mm) outlets. In front of the door, keep 25 in. of clear space. Lifebreath offers the wall control as an option.

Filters

On the stale-air side as on the fresh-air side, the air passes through a washable MERV 6 filter. To move up to MERV 13, Lifebreath's spec sheet gives part 65-192-6R for this model, not the 65-195-6R of the other RNC5 units.

Warranty

Lifebreath warrants the core for life, and the motors and parts for 5 years.

Which home it suits

The RNC5-TPD is aimed at a single-family home that needs airflow but whose mechanical room, already taken up by the furnace and the electrical panel, has no space for a long unit. It is also a good choice to replace an old air exchanger installed in a tight spot, and its performance at −25 °C makes it a serious option for a house exposed to the cold.

Installation by AirGreen in Greater Montreal

We assess the home's ventilation needs on site (bedrooms, bathrooms, kitchen, basement), then compare the total with the RNC5-TPD's 155 cfm net. If the home needs clearly more, or clearly less, we will suggest another model.

When the fresh air is sent into the furnace return and the stale air is drawn from the kitchen and bathrooms, it is called a partially dedicated installation: Lifebreath then recommends running the furnace blower non-stop, or interlocking it with the HRV's operation. At the outside wall, a thermal collar slipped over the galvanized sleeve fully seals the vapour barrier to the wall plate. Lifebreath adds that, under certain conditions, a secondary drain pan may be needed to protect against a condensate leak. During balancing, everything that exhausts air outdoors is turned off, such as the range hood, the dryer and the bathroom fans; appliances that exhaust air outside should have their own make-up air, since that is not the HRV's job.

Our team, under AirGreen's RBQ licence 5645-9605-01, works in Montreal and Laval, in Longueuil and on the South Shore, as well as on the North Shore.

Since October 1, 2026, Rénoclimat no longer funds HRV or ERV installations, except for a home already evaluated before the change whose post-work evaluation is done by March 31, 2027.

For an installed price, ask for a free quote at 514 316-2973 or sales@airgreen.ca.