Lifebreath RNC6-ES HRV Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore
Is it the right size for your home?
It delivers 150 cfm net, enough to ventilate 1,700 to 2,800 sq ft. Choose your home's living area.
It's the right size.
For a 1,500 to 2,500 sq ft home, about 105 cfm of air needs to be renewed continuously. This unit delivers 150 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. We set the exact airflow during our on-site assessment.
What it does, in numbers
$45.87
Electricity per year
Less than a 60 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Meets both thresholds of the Québec Construction Code (art. 9.36.3.9). At −25 °C and at least 22 L/s, the Code (art. 9.36.3.9, in force since April 17, 2025) requires 55% where there are fewer than 6,000 heating degree-days and 60% elsewhere. This unit is rated at 60% at 70 cfm (HVI).
Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 47 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
DoorBalancing ports built into the door
The ports used to measure and balance airflow are located on the unit's door, and the dampers are adjustable. This makes commissioning simpler for the installer.
Hi3Selectable high speed
DIP switches on the circuit board let the installer choose the high speed (Hi3 is the factory setting), so the maximum airflow can be matched to the home's real needs.
60%What it still recovers at −25 °C
The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 70 cfm.
DamperIt defrosts with indoor air
In cold weather, a motorized damper closes the outdoor air intake and recirculates indoor air through the core to thaw it. During the cycle, no outdoor air comes in through the unit.
HRVIt recovers heat, not moisture
Excess moisture leaves the house. In Québec, that's the right choice in most cases: in winter, a house almost always has too much humidity, not too little.
2505098Its HVI certification number
Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.
−24 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 174 to 150 cfm. Most spec sheets show only the first number, precisely because it looks better.
47 WMeasured at the airflow it actually runs at
Its 65% at 0 °C is certified at 64 cfm, the continuous airflow of a typical home. At that setting it draws 47 W, or about 412 kWh a year.
LifetimeThe core warranty
The core does the work and is the most expensive part to replace. Motors and parts: 5 years.
5 inWhat it needs on site
5 in ducts, top connection and a condensate drain. It weighs 51 lb, and it needs enough clearance to slide the core out for cleaning.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 174 cfm
- Net airflow at 0.4 in. w.g.
- 150 cfm
- SRE at 0 °C (64 cfm)
- 65%
- SRE at −25 °C (70 cfm)
- 60%
- ASE at 0 °C
- 70%
- Power draw
- 47 W
- Efficacy
- 1.4 cfm/W
- Type
- HRV
- Connection
- Top ports
- Duct collars
- 5 in
- Condensate drain
- Required
- Defrost cycle
- Recirculation (motorized damper)
- Filters
- 2 washable MERV 6 filters (exhaust and supply); MERV 13 upgrade (65-195-6R)
- Dimensions (L × D × H)
- 22.75 × 14 × 17.25 in
- Weight
- 51 lb
- Power supply
- 120 V
- HVI certification (Section III)
- 2505098
- Warranty — core
- Lifetime
- Warranty — motors
- 5 years
- Warranty — parts
- 5 years
Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2505098). Annual consumption calculated at 47 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
We assess your needs on site, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
Lifebreath RNC6-ES: a compact HRV that draws little power
At AirGreen, we install the Lifebreath RNC6-ES air exchanger, a 51 lb heat recovery ventilator (HRV) whose cabinet measures 22 3/4 in. by 17 1/4 in. by 14 in. Natural Resources Canada includes it on its ENERGY STAR list, and Lifebreath's spec sheet adds a qualification: the unit meets those requirements only when used in Canada.
Polymer/Aluminum Cross-Flow Core
Its cross-flow core, made of polymer and aluminum, moves part of the heat from the stale air leaving the house to the fresh air coming in. It slides out of the unit easily for cleaning or service.
Motors and Speeds
An independent motorized impeller drives each of the two airstreams, at several speeds. High speed is selected with the DIP switches on the circuit board, and the unit leaves the factory set to Hi3.
Filtration
Two washable MERV 6 filters handle the stale air and the fresh air. To capture finer particles, Lifebreath offers MERV 13 filters under part 65-195-6R.
Mounting and Clearance
The cabinet hangs from four threaded inserts at its corners, which take the S hooks and hanging straps Lifebreath supplies. The unit must sit perfectly level so condensation drains properly, and Lifebreath recommends keeping 25 in. (635 mm) clear in front of the door for service.
Recirculating Damper Defrost
In cold weather, its intelligent recirculating damper defrost system keeps frost from settling in the core. Lifebreath points out that a defrost cycle can produce some condensation, which is why the unit connects to a drain.
Cabinet, Drain and Balancing
The cabinet's 22-gauge prepainted galvanized steel resists corrosion, and its insulation keeps condensation from forming on its outer walls. Water drains out through two drain outlets with a 12 mm (1/2 in.) outside diameter. The balancing ports are on the door and the balancing dampers are adjustable, which makes setting the airflows at start-up easier.
Controls and Timers
Offered as an option, the wall control calls for 3-wire low-voltage wiring, 20 gauge at minimum, up to 100 ft long. With Lifebreath's 99-DXPL03 control, you get:
- Five fan speeds, selected with a single press of the fan button.
- An electronic dehumidistat, adjustable from 25% to 60% relative humidity, to keep excess humidity in check.
- A back-lit LCD screen, which shows indoor humidity in large numbers.
- Continuous ventilation, one of the control's operating modes.
- The 99-DET02 wireless timer: it starts high speed for 20, 40 or 60 minutes and pairs wirelessly with the main control.
HVI-Certified Performance
The RNC6-ES is listed in the HVI directory under number 2505098. At 0°C and 64 cfm (30 L/s), HVI gives it 65% sensible recovery efficiency at a power draw of 47 W, or 1.4 cfm per watt. At −25°C and 70 cfm (33 L/s), its sensible recovery efficiency is 60% (HVI directory, November 4, 2026 edition). The Québec Construction Code (art. 9.36.3.9) requires at least 55% where there are fewer than 6,000 heating degree-days and 60% elsewhere, at no less than 22 L/s. The RNC6-ES therefore meets both thresholds. Its net airflow is 174 cfm at 0.2 in. of static pressure and 150 cfm at 0.4 in.
Running continuously at 64 cfm, its 47 W come to about 412 kWh a year, or close to $46 at Hydro-Québec Rate D (second tier, 11.142 ¢/kWh). For comparison, HVI measures 79 W for Lifebreath's RNC5-TPD at the same test airflow.
Warranty
Lifebreath's warranty covers the HRV core for life and replacement parts for 5 years.
Installation by AirGreen
Before recommending the RNC6-ES, we assess the home's ventilation needs on site (bedrooms, bathrooms, kitchen, basement). It is a good fit when those needs stay under its 150 cfm net at 0.4 in. and basement space is tight, since its longest side is only 22 3/4 in. Beyond that, we point you to a higher-capacity Lifebreath model.
For the drain, we build a P-trap with the plastic tee connector and two lengths of 1/2 in. hose, then pour a cup of water into the unit's drain pan once the connection is complete. The trap and hose run below the bottom of the door and slope down 1/4 in. per foot as they move away from the unit. On the electrical side, Lifebreath calls for a grounded 120 V outlet and advises against any extension cord; a 15 A circuit dedicated to the unit is recommended. We also insulate the two ducts that connect the RNC6-ES to the outdoors along their full length, right back to the unit.
At start-up, the RNC6-ES runs on high speed, with the furnace blower on if there is one. We then gradually reduce the stronger airflow with its damper until as much fresh air is blown into the house as stale air is expelled.
For a free quote, call us at 514 316-2973 or write to sales@airgreen.ca: we will call you back. Our team, under AirGreen's RBQ licence 5645-9605-01, installs the RNC6-ES in Montreal, Laval, Longueuil, the North Shore and the South Shore.