GENERAL AIRSTAGE CENTAURI XLTH R32 Electric Furnace | 2.5 Tons - 30000 BTU

In stock
SKU: 217895716
21,000BTU/h of heat at −8 °C (certified)
−26 °Ccoldest published heating point
$2,520LogisVert grant (Hydro-Québec)
ENERGY STAR® · cold climateR-32Optional Wi-Fi12-year compressor warranty
Talk to a technician · 514 316-2973
Indoor unit (air handler)AMUH30KUAS
Outdoor unit (heat pump)AOUH30KUAH1
AHRI certificate217895716

GENERAL AIRSTAGE CENTAURI XLTH 30,000 BTU electric furnace: when the northern cold settles in, the backup stays in reserve

In Prévost, north of Saint-Jérôme, at the gateway to the Laurentians, January nights tend to bite harder than in the city. An electric furnace there keeps its elements working non-stop. A GENERAL AIRSTAGE CENTAURI XLTH system, here in 30,000 BTU (2.5 tons), replaces it while keeping the duct system: the AMUH30KUAS multi-position air handler goes in its spot, and the AOUH30KUAH1 outdoor unit, a very-low-temperature Heat Pump, supplies the heat down to −26 °C according to the manufacturer.

The twin Fujitsu AIRSTAGE CENTAURI XLTH page describes the same units, down to the model number. The manufacturer has not changed either: Fujitsu General Limited has been called GENERAL Inc. since January 1, 2026, and both names share the manufacturer's spec sheet and its warranty.

Here, the whole point of the XLTH unit lies in the coldest stretch of winter. Between −21 °C and −26 °C, a standard CENTAURI heat pump would already have handed over to the backup; the XLTH unit keeps heating. The electric backup heat kit installed in the air handler is then only needed on the worst nights.

GENERAL or Fujitsu AIRSTAGE: the same machine

The XLTH unit's low-temperature heating range is published by the manufacturer's American subsidiary, also renamed on January 1, 2026. In other words, the data come from the same house as before, under a new name. Nothing changed in the factories, in the AIRSTAGE model numbers or in the warranty program.

Until the Fujitsu brand has fully disappeared, both labels will designate the same unit. Hence our two pages, and the comparison that follows: it shows no difference at all.

SpecificationGENERAL AIRSTAGEFujitsu AIRSTAGE
Indoor unitAMUH30KUASAMUH30KUAS
Outdoor unitAOUH30KUAH1AOUH30KUAH1
AHRI certificate217895716217895716
Nominal capacity30,000 BTU30,000 BTU
RefrigerantR-32R-32
Power supply208/230 V208/230 V
SEER218.818.8
HSPF210.010.0
EER212.212.2
Heating capacity at −8 °C21,000 BTU21,000 BTU
COP at −8 °C2.962.96
Heating capacity at −15 °C34,000 BTU34,000 BTU
COP at −15 °C2.102.10
Heating down to (manufacturer operating range)−26 °C−26 °C
ENERGY STARYesYes
Cold climate (ENERGY STAR)YesYes
ENERGY STAR ID45117724511772
Indoor unit dimensions (W × D × H, in)21 x 21 x 4821 x 21 x 48
Outdoor unit dimensions (W × D × H, in)39.31 x 12.60 x 37.0139.31 x 12.60 x 37.01
Indoor sound level (min / max)32 / 43 dB(A)32 / 43 dB(A)
Outdoor sound level57.0 dB(A)57.0 dB(A)
Airflow1,000 CFM1,000 CFM
Dehumidification3.5 pints/h3.5 pints/h
Wi-FiOptionalOptional
LogisVert grant (Hydro-Québec, list of October 27, 2026)$2,520$2,520
Warranty (compressor · parts · labour, years)12 · 12 · 612 · 12 · 6
ManufacturerGENERAL Inc. (Kawasaki, Japan)GENERAL Inc. (Kawasaki, Japan)
Product pageThis pageFujitsu AIRSTAGE CENTAURI 30,000 BTU

The page under the former name is here: Fujitsu AIRSTAGE CENTAURI XLTH 2.5-ton electric furnace.

In the mechanical room, the change is quickly described. The furnace comes out; the AMUH30KUAS, a 21 × 21 × 48 in. cabinet (W × D × H), moves into the freed-up space and ties into the plenum and return air after the ducts have been examined. Being multi-position, it can work upflow, downflow if you add the UTD-DFMMB1 kit, or lying on one side or the other. The grilles in the rooms stay put; duct routing and grille count are confirmed on site.

To judge this system in deep cold, here are the figures that matter. The AOUH30KUAH1 provides low-ambient heating down to −26 °C and cooling from −21 °C to 50 °C. The certification tests add two reference points, each measured under its own conditions: 21,000 BTU with a COP of 2.96 at −8 °C, and 34,000 BTU with a COP of 2.1 at −15 °C, two values we report as they are. On AHRI certificate 217895716, the system earns a SEER2 of 18.8, an HSPF2 of 10.0 and an EER2 of 12.2; ENERGY STAR recognizes it in its cold climate category (ID 4511772).

Even with an XLTH unit, you need backup. Below −26 °C, or when the house loses more heat than the heat pump can supply, the electric kit takes over. The air handler offers several backup heat logics; in Prévost, we favour a setting that lets the heat pump work as long as possible and calls on the elements last. Sold separately, the manufacturer's compatible kit gets its own power supply; the heat pump has its own as well, at 208/230 V (MCA 21 A, MOP 25 A).

In the northern part of the territory, the outdoor unit's location is decided with snow in mind. The unit measures 39.31 × 12.60 × 37.01 in., and we place it:

  • raised on a pad or a bracket, above the usual snow build-up on the property;
  • away from a roof slope or a gutter that dumps snow and ice;
  • out of the path of the snowblower and the driveway snowbanks;
  • far from bedroom windows, since the unit is rated at 57 dB(A).

To reach the indoor unit, the refrigerant line, with its 3/8 and 5/8 in. tubes, travels with the cable and the drain, along a route set during the visit.

For air distribution, the AMUH30KUAS goes up to 1,000 CFM, with an allowable external static pressure of 0.2 to 0.8 in. WC. Those values only help if the return air keeps up, and it is a point we check every time on an old electric furnace duct system. Indoors, the air handler stays between 32 and 43 dB(A). In summer, it cools through the same ducts and dehumidifies at 3.47 pints/h, according to the spec sheet.

We build an access panel in front of the filter. A refrigeration technician commissions the system and, at the same time, sets the backup logic; our company, which holds an RBQ licence, has AIRSTAGE Elite Plus installer status. The air handler includes its own leak detection system.

No control is supplied. The UTY-TTRXZ1 interface lets you keep a 24 V thermostat, provided it handles a heat pump and its backup. The other choices: a wired KAGAMI controller (UTY-RVRU or UTY-RNRUZ5), the AIRSTAGE Mobile app over Wi-Fi, or a wireless remote paired with an IR receiver kit. With a compatible controller, service monitoring is added.

The filter can sit in an optional 20 × 20 in. base. In the dead of winter, the system runs for long stretches: checking the filter more often than usual keeps it from choking the airflow just when the house needs it most.

For the LogisVert grant, Hydro-Québec listed this system at $2,520 in its list of October 27, 2026; the list in force on the day you apply takes precedence. Under the manufacturer's warranty, the compressor and the parts get 12 years, labour gets 6. AirGreen also offers this system under the "central heat pump" name.

This size is meant for the house with ducts, heated today by an electric furnace, where the cold hits harder than in the city. The 2.5 tons are confirmed by a heat-loss calculation done on site; if the house needs more, a larger size exists in the same series, and we will tell you. Let us also be clear on one point: no heat pump makes the backup useless, it shrinks its role.

Official brochures

The manufacturer's brochures are available as PDF files:

Prévost and the North Shore: have your electric furnace assessed for free

Our crews travel to Prévost and throughout the North Shore, and the territory of AirGreen, an HVAC contractor, also extends to Laval, Montreal, Longueuil and the South Shore. One call to 514 316-2973 and we schedule the visit for your free quote: on site, we look at the mechanical room, the duct system, the electrical service and the corner of the property that will host the outdoor unit.

If you know how old your furnace is, write it down before calling. It helps us know what we will find when we open the mechanical room.