SAMSUNG HYLEX STANDARD R454B Electric Furnace | 3 Tons

In stock
SKU: 218158143
Provincial Subsidy (LogisVert): 0 $ (Updated: November 26, 2025)
Model Number: HH36MCBC11H1
AHRI: 218158143
Works with the Central Heat Pump: AC036FCUDCG
ENERGY STAR: No
ENERGY STAR (COLD CLIMATE*): No / No
# ENERGY STAR ID: -
Heating Capacity (Heat Pump): -25 °C
Cooling Capacity: 36,000 BTU
Gas (Freon): R-454B
WiFi: Included

SEER2 (Seasonal Air Conditioning Efficiency)

1 14.6 30

HSPF2 (Seasonal heating efficiency)

1 8.2 15

EER2 (Instantaneous efficiency in air conditioning)

1 9.5 20

COP at -8 °C (Heating energy efficiency)

1 1.85 3
Size: 3 Tons
Nominal Power: 36,000 BTU
Power at -8°C: 22000 BTU
Power at -15°C: 24800 BTU
Interior Dimensions (L x D x H): 18.5 x 22 x 41 in
Dehumidification: pt/h
Sound Pressure Level (Indoor): TBD dB(A)

CFM (Airflow)

1 1297
External Dimensions (L x W x H): 37 x 13 x 39.31 in
Piping: 3/8 - 3/4
Sound Pressure Level (Exterior): 55.0 dB(A)
Voltage: 220 V
MCA (Minimum Circuit Ampacity): 25 A
MOP (Maximum Overcurrent Protection): 30 A
Warranty (Compressor - Parts - Labor): 12-12-0 years
Additional Warranty: Possible

(French brochure coming soon)

A reliable central HVAC solution optimized for Quebec's climate

At AirGreen, we install and maintain central HVAC systems designed to meet the real demands of residential and multi-dwelling properties in Greater Montreal, Laval, Longueuil, North Shore, and South Shore. The SAMSUNG HYLEX STANDARD R454B 3-ton electric furnace fits this approach: a modern system, compatible with central heat pumps, that prioritizes stability, performance, and ease of installation.

This model is particularly aimed at homeowners looking to replace an existing furnace or integrate a complete solution with a heat pump, without compromising on reliability or indoor comfort control.


Understanding the HYLEX system: much more than just a furnace

A system designed to work with a central heat pump

Unlike a traditional electric furnace, the SAMSUNG HYLEX STANDARD R454B acts as an indoor unit (air handler) in combination with a compatible central heat pump (model AC036FCUDCG). This type of configuration allows for:

  • A uniform distribution of hot and cold air throughout the house
  • Intelligent heating and cooling management
  • Adaptation to outdoor temperatures down to -25°C
  • Better overall efficiency compared to electric-only systems

In practice, this means your system doesn't rely solely on electric resistance heaters, but uses the heat pump as the primary source, thereby reducing energy consumption.


Key technical data to remember

Here are the most important elements to consider for this model:

  • Capacity: 3 tons (36,000 BTU)
  • Refrigerant: R-454B (new generation, more environmentally friendly)
  • Heating capacity: up to -25°C
  • Power at -8°C: 22,000 BTU
  • Power at -15°C: 24,800 BTU
  • SEER2: 14.63
  • HSPF2: 8.21
  • EER2: 9.52
  • Voltage: 220V
  • Integrated WiFi
  • Outdoor sound level: 55 dB(A)

These figures translate into a stable system, capable of maintaining good performance even in typical Quebec winter conditions.


HVAC installation: what AirGreen has learned in the field

Real-world example in Montreal (central system replacement)

During a recent project in a duplex in Montreal East, our team replaced an old electric furnace combined with an aging air conditioner. The challenges encountered:

  • Restricted mechanical space
  • Existing ducts to optimize
  • Excessive noise from the old system

With the SAMSUNG HYLEX 3 tons, we were able to:

  • Install a compact system (18.5 x 22 x 41 inches) perfectly suited
  • Significantly reduce noise thanks to the variable-speed ECM fan
  • Improve air circulation with better flow management (optimized CFM)

Result: more stable temperature, fewer variations between rooms, and a noticeable reduction in perceived noise.


Installation flexibility: a major advantage

One of the strengths of this unit is its multi-position configuration:

  • Vertical installation
  • Horizontal left or right installation
  • Downflow installation (with accessories)

This allows our AirGreen technicians to adapt to almost all mechanical configurations, whether it's:

  • Residential basement
  • Compact mechanical room
  • Multi-dwelling projects

Performance and efficiency: what changes concretely

Intelligent airflow management

The high-efficiency ECM motor offers:

  • 5 fan speeds
  • Automatic adaptation based on demand
  • Reduced vibrations and noise

In a real context, this means:

  • Fewer harsh cycles
  • Better dehumidification in summer
  • More homogeneous air distribution

Advanced refrigeration system

The system uses:

  • Dual-rotor BLDC inverter compressor
  • Electronic expansion valve (heating)
  • TXV (air conditioning)

This type of management allows for precise modulation, avoiding energy losses and improving comfort.


Construction quality

AirGreen places great importance on durability. On this model:

  • Galvanized steel casing with durable finish
  • Internal insulation (5/8”) to limit thermal losses
  • Air leakage tested at less than 2%

These are details often overlooked but directly influence long-term performance.


HVAC maintenance and reliability: points to watch

Simplified access for service

Two access panels allow for:

  • Quick maintenance
  • Efficient inspection
  • Reduced intervention time

At AirGreen, this translates into:

  • Better controlled maintenance costs
  • Faster diagnostics
  • Improved system longevity

Drainage and mold protection

The HYDROTEC drain pan integrates:

  • Microban antimicrobial technology
  • Reduced water accumulation
  • Corrosion-resistant materials

In several installations on the South Shore, we have found that this type of design significantly reduces odor and humidity problems.


Common mistakes to avoid with this type of system

Over the years, we have identified several common mistakes:

1. Undersizing or oversizing capacity

Poor evaluation can lead to:

  • Too frequent cycles
  • Poor energy efficiency
  • Unstable comfort

2. Neglecting heat pump compatibility

The HYLEX model requires a precise match with the outdoor unit.

3. Ignoring the quality of existing ducts

Even the best system will not compensate for poorly designed ducts.

At AirGreen, we always include a complete analysis before installation.


Why choose AirGreen for this type of installation

Recognized local expertise

We operate daily in:

  • Montreal
  • Laval
  • Longueuil
  • North Shore
  • South Shore

Our teams are familiar with the real constraints of Quebec buildings.


Transparent and structured approach

  • Clear final price before work
  • Comprehensive needs analysis
  • Compliance with RBQ standards
  • 5M$ liability insurance

Optimized installation from the start

We ensure that:

  • Piping (3/8 - 3/4) is adapted
  • Electrical integration (MCA 25A / MOP 30A) complies
  • The system is correctly calibrated from the outset

Conclusion: a consistent and durable central HVAC solution

The SAMSUNG HYLEX STANDARD R454B 3-ton electric furnace represents a solid option for any modern central HVAC installation in Greater Montreal. It combines:

  • Efficient heat pump compatibility
  • Flexible installation
  • Stable performance in cold climates
  • A design focused on maintenance and durability

It is a particularly relevant choice for replacing existing systems or projects requiring a reliable central solution.


Take action with AirGreen

Are you considering installing an electric furnace or a central system with a heat pump in Montreal, Laval, Longueuil, North Shore, or South Shore?

Contact AirGreen today for:

  • A free estimate
  • A personalized technical analysis
  • A clear and surprise-free proposal

Call us or write to us at sales@airgreen.ca — our team will support you from start to commissioning.