SAMSUNG HYLEX STANDARD R454B Electric Furnace | 4 Tons

In stock
SKU: 218158144
Provincial Subsidy (LogisVert): 0 $ (Updated: November 26, 2025)
Model Number: HH48MCCC11H1
AHRI: 218158144
Works with the Central Heat Pump: AC048FCUDCG
ENERGY STAR: No
ENERGY STAR (COLD CLIMATE*): No / No
# ENERGY STAR ID: -
Heating Capacity (Heat Pump): -25 °C
Cooling Capacity: 48,000 BTU
Gas (Freon): R-454B
WiFi: Included

SEER2 (Seasonal Air Conditioning Efficiency)

1 14.3 30

HSPF2 (Seasonal heating efficiency)

1 8.0 15

EER2 (Instantaneous efficiency in air conditioning)

1 9.5 20

COP at -8 °C (Heating energy efficiency)

1 1.99 3
Size: 4 Tons
Nominal Power: 48,000 BTU
Power at -8°C: 30200 BTU
Power at -15°C: 40000 BTU
Interior Dimensions (L x D x H): 21.88 x 26 x 48 in
Dehumidification: pt/h
Sound Pressure Level (Indoor): TBD dB(A)

CFM (Airflow)

1 1971
External Dimensions (L x W x H): 37 x 13 x 43.63 in
Piping: 3/8 - 7/8
Sound Pressure Level (Exterior): 57.0 dB(A)
Voltage: 220 V
MCA (Minimum Circuit Ampacity): 34 A
MOP (Maximum Overcurrent Protection): 40 A
Warranty (Compressor - Parts - Labor): 12-12-0 years
Additional Warranty: Possible

(French brochure coming soon)

A Reliable and High-Performance Central HVAC Solution for Greater Montreal Properties

At AirGreen, we regularly install central systems adapted to Quebec's climatic realities. The SAMSUNG HYLEX STANDARD R454B electric furnace | 4 tons stands out as a structured and coherent option for homeowners seeking a combined heating and central air conditioning solution with a compatible heat pump. This type of equipment is particularly well-suited to the needs of residences and small buildings located in Montreal, Laval, Longueuil, the North Shore, and the South Shore, where temperature variations are significant and require consistent performance.

A Central Configuration Designed for Winter and Summer Performance

Compatibility with Samsung Central Heat Pump

This model is designed to work with a compatible central heat pump, specifically the AC048FCUDCG model, allowing for intelligent heating management down to very low outdoor temperatures. Concretely, this means:

  • Heating capacity maintained down to -25°C
  • Seamless transition between heat pump and electric heating
  • Reduced energy costs in mid-season

In several installations carried out by AirGreen in Boucherville and Laval, this combination has significantly reduced overall electricity consumption while ensuring stable comfort.

Energy Performance and Real Power

With a capacity of 48,000 BTU (4 tons), this furnace is suitable for medium to large areas. Here are some key technical data:

  • Power at -8°C: 30,200 BTU
  • Power at -15°C: 40,000 BTU
  • SEER2: 14.3
  • HSPF2: 8.0
  • EER2: 9.5
  • COP at -8°C: 1.99

These figures indicate stable performance, particularly well-suited for well-insulated single-family homes and plexes in the Longueuil and South Shore areas.

R-454B Refrigerant: A Transition to the Future

The system uses R-454B gas, known for its reduced environmental impact compared to R-410A. This allows for:

  • Compliance with new environmental standards
  • Improved thermal efficiency
  • Long-term value for the property

At AirGreen, we strongly recommend this type of refrigerant for new HVAC installations in Greater Montreal, as it is part of a sustainable transition.


HVAC Installation: What You Need to Know Before Choosing This Model

Dimensions and Installation Constraints

The indoor furnace has dimensions of:

  • 21.88 x 26 x 48 inches

This compact size facilitates installation in:

  • Residential basements
  • Technical closets
  • Restricted mechanical rooms

We recently installed this model in a triplex in Ahuntsic, where space was limited. Thanks to its vertical configuration and multi-position options (vertical, horizontal left/right, downflow), the installation was carried out without major structural modifications.

Airflow and Indoor Comfort

With an airflow of 1197 CFM, this unit allows for:

  • Uniform air distribution
  • Improved dehumidification
  • Compatibility with various existing duct networks

The variable-speed ECM motor offers operation that is:

  • Quiet
  • Stable
  • Energy optimized

In several projects in Laval, our clients have noticed an immediate improvement in thermal comfort after installation.

Piping and Connections

  • Piping: 3/8 – 7/8
  • Simplified connections with outdoor units
  • Compatibility with several duct configurations

Please note: when replacing, it is essential to check if the existing piping is compatible. At AirGreen, we often encounter cases where old installations require adaptation, which can influence the final cost.


Robust Construction and Simplified Maintenance

Materials and Durability

The structure is designed with:

  • Galvanized steel
  • Quality internal insulation
  • Easy front access for maintenance

These elements ensure better durability in humid environments like typical basements in Montreal and Longueuil.

HYDROTECT Drainage System

An often overlooked but essential point:

  • Drain pan with antimicrobial treatment
  • Reduced risk of mold
  • Double drain (left/right)

During our HVAC maintenance interventions, we observe that this type of design significantly reduces humidity-related problems.


Smart Control and Connectivity

Thermostat and SmartThings Integration

The system allows for:

  • Control via 24VAC thermostat
  • Integration with Samsung controllers
  • WiFi connection included
  • Remote monitoring via app

This allows homeowners to:

  • Adjust temperature remotely
  • Optimize energy consumption
  • Receive alerts in case of problems

We have installed this type of configuration in several homes in Terrebonne and Brossard, where clients particularly appreciate remote management.


Real AirGreen Installation Cases

Project in Laval – Complete HVAC Replacement

A client had an old inefficient central system. We:

  • Replaced the electric furnace
  • Installed the HYLEX 4 tons
  • Adapted existing ducts

Result:

  • Reduced energy costs
  • Better air distribution
  • Noise reduction

Project in Longueuil – Duplex Optimization

In this case, the main constraint was limited space. Thanks to the unit's flexibility:

  • Installation without structural modification
  • Integration with heat pump
  • Improved thermal comfort on two floors

Common Mistakes to Avoid

Underestimating Required Capacity

A 4-ton system is not suitable for all properties. Incorrect evaluation can lead to:

  • Excessive energy consumption
  • Thermal discomfort
  • Premature wear

At AirGreen, we always perform a complete analysis before any HVAC installation in Montreal, Laval, or the South Shore.

Neglecting Duct Compatibility

High airflow requires an adequate duct network. Otherwise:

  • Excessive noise
  • Loss of efficiency
  • Poor air circulation

Ignoring HVAC Maintenance

Even with a high-performance unit:

  • Regular cleaning required
  • Drain verification
  • Annual inspection recommended

Why Choose AirGreen for Your HVAC Installation

We operate daily in Greater Montreal, with a structured approach:

  • Complete technical analysis before installation
  • Transparent pricing
  • Installation compliant with RBQ standards
  • Experienced and certified technicians
  • Clear warranty and extended options

Our field experience allows us to anticipate specific constraints for each building, whether it is located in Montreal, Laval, Longueuil, the North Shore, or the South Shore.


Conclusion: An Efficient and Evolving Central Solution

The SAMSUNG HYLEX STANDARD R454B electric furnace | 4 tons represents a reliable solution for modern central HVAC systems. It combines:

  • Stable thermal performance
  • Heat pump compatibility
  • Connected technology
  • Flexible installation

This type of equipment is aimed at homeowners seeking a durable solution adapted to Quebec's climatic realities.


Contact AirGreen

For a precise quote, a technical evaluation, or to schedule an installation, contact our team directly. We cover Montreal, Laval, Longueuil, the North Shore, and the South Shore, with fast and professional service.