FUJITSU AIRSTAGE J-7S VRF R32 | 48000 BTU - 7 Indoor Units

In stock
SKU: AOUK048SSAN7-7
Provincial Subsidy (LogisVert): 4296 $ (Updated: November 26, 2025)
Model Number (External): AOUK048SSAN7
AHRI: 216372783
ENERGY STAR®: Yes
ENERGY STAR® (Cold Climate): Yes / Yes
# ENERGY STAR ID: 3813053
Heating Capacity: -26 °C
Cooling Capacity: 48,000 BTU
Gas (Freon): R-32
WiFi: Optional

SEER2 (Seasonal Air Conditioning Efficiency)

1 20.2 30

HSPF2 (Seasonal heating efficiency)

1 10.2 15

EER2 (Instantaneous efficiency in air conditioning)

1 11.4 20

COP at -8 °C (Heating energy efficiency)

1 2.1 3
Nominal Power: 48,000 BTU
Power at -8°C: 35800 BTU
Power at -15°C: 41500 BTU
Possible Model Number (Interior): Slim, taperable garment - ARUL***KSA1, Compact cassette - AUUA***KSA1, Wall mount - ASUA***KSA1, and Multi-position air handling unit - ARUX***KSA1

Maximum Pipe Length (feet)

1 164 200

Maximum Height Difference (feet)

1 98
External Dimensions (L x W x H): 39.31 x 12.63 x 37 in
Zones: 7 Areas
Maximum Zones: 12
Sound Pressure Level (Exterior): 60.0 dB(A)
Voltage: 220 V
MCA (Minimum Circuit Ampacity): 36 A
MOP (Maximum Overcurrent Protection): 40 A
Warranty (Compressor - Parts - Labor): 12-12-0 years
Additional Warranty: Possible

A Mini-VRF R-32 platform designed for demanding buildings in Greater Montreal

At AirGreen , we design and install HVAC systems for buildings where standard solutions quickly reach their limits: multi-unit residential buildings, urban plexes, light commercial buildings, professional offices, intergenerational residences and large properties in Montreal , Laval , Longueuil , on the North Shore , the South Shore and in Montérégie .
The FUJITSU AIRSTAGE J-7S VRF R32 – 48,000 BTU is specifically designed for this type of project. It is a compact Mini-VRF system, stable in heating conditions even in very cold weather, capable of powering up to 7 active indoor units (and up to 12 depending on the configuration), while maintaining precise modulation and high energy efficiency.

This system is neither a conventional multi-zone heat pump nor an oversized commercial VRF. It occupies a strategic space between the two, offering a coherent solution for buildings that require installation flexibility , independent zone control , and reliability in Quebec winters .


Understanding the true value of the AIRSTAGE J-7S Mini-VRF

In our field experience, several clients come to us after experiencing the limitations of a poorly adapted HVAC system:
thermal imbalances between floors, excessive noise, inability to maintain temperature during cold spells, major constraints on piping length or impossibility of adding additional zones.

The AIRSTAGE J-7S addresses these issues in a structural way.

  • Continuous heating down to −26 °C , without stopping the compressor, which eliminates the inefficient restart cycles observed on systems less adapted to the local climate.

  • Fine-modulation VRF technology , allowing precise adjustment of the refrigerant flow according to the actual demand of each zone.

  • R-32 refrigerant , more thermodynamically efficient and requiring a reduced overall charge, with integrated safety mechanisms.

  • Compact outdoor unit , designed for urban environments where space is a real constraint: balconies, narrow backyards, flat roofs, areas under windows.

In practice, these characteristics translate into superior thermal stability , better controlled power consumption and design flexibility that greatly simplifies complex projects.


A 48,000 BTU outdoor unit designed for complex configurations

Actual thermal capacity for heating and cooling

The AOUK048SSAN7 outdoor model has a rated output of 48,000 BTU , but this figure alone is insufficient to assess its actual performance. What distinguishes this system is its ability to maintain usable output at low temperatures:

  • Approximately 35,800 BTU at −8 °C ,

  • Approximately 41,500 BTU at −15 °C ,

  • Stable operation down to −26 °C .

In the projects we are carrying out in Laval and on the North Shore , this capacity makes it possible to avoid the use of energy-intensive backup systems or massive electrical resistances, which are often responsible for significant increases in consumption.

Pipe lengths and height differences

The AIRSTAGE J-7S accommodates long total pipe lengths and significant height differences between the outdoor and indoor units. This opens the door to configurations that would otherwise be impossible with traditional multi-zone systems:

  • Multi-story buildings,

  • Buildings with an outdoor unit installed in a recessed position,

  • Projects where aesthetics or municipal regulations impose strict constraints.

For AirGreen , this flexibility reduces technical compromises and allows for real optimization of HVAC installation according to the building, and not the other way around.


Advanced multi-zone management, adapted to real-world uses

Up to 7 active indoor units, with a full range of sizes

The FUJITSU AIRSTAGE J-7S is compatible with several types of indoor units, allowing for the design of customized systems:

  • Slim ducted : preferred solution for invisible integration, ideal in high-end renovations or common areas.

  • Compact cassette : widely used in shops, clinics and offices thanks to its uniform diffusion and integration into standard ceilings.

  • Wall unit : quiet, efficient and perfectly suited for bedrooms, closed offices and private accommodations.

  • Multi-position air handling unit : chosen when larger air volumes or complex ductwork systems are required.

In several projects in Longueuil and on the South Shore , we combine, for example, ducted units for open areas, wall units for private spaces and a compact cassette for a professional space, all powered by a single outdoor unit.


Energy efficiency and subsidies: a tangible impact

The AIRSTAGE J-7S is ENERGY STAR® certified, including Cold Climate recognition, a key criterion for eligibility for provincial subsidy programs, including LogisVert .

Beyond certifications, this system is distinguished by:

  • high seasonal efficiency in air conditioning ,

  • consistent heating performance , even during periods of prolonged cold.

  • improved modulation , reducing the on/off cycles responsible for energy losses.

In AirGreen installations, this translates into more predictable consumption and operating costs, a point particularly appreciated by owners of multi-unit residential buildings.


Safety, reliability and design for Quebec winters

Advanced R-32 Refrigerant Management

The system integrates leak detection sensors on the ducted indoor units, with options for alarms and automatic refrigerant shut-off devices. This approach is essential in buildings where multiple occupants share the same HVAC system.

The reduced overall refrigerant charge also decreases risks and facilitates compliance with current safety standards.

Designed to work when conditions are tough

  • Integrated base heating to prevent ice buildup and ensure reliable starting.

  • Electronic components are cooled by the refrigerant , which improves reliability during periods of extreme cold.

  • Controlled outdoor noise levels , a crucial element in the dense residential areas of Montreal and Laval .


Concrete examples of installations carried out by AirGreen

Mixed-use building in East Montreal

In a building combining a commercial space on the ground floor and two residential floors, the main constraints were the limited space for the outdoor unit and the need for independent thermal control.
The AIRSTAGE J-7S 48,000 BTU enabled:

  • a discreet installation below the window line,

  • a zone-based management system adapted to the different opening hours of shops and residences,

  • a significant reduction in temperature differences between floors.

Intergenerational residence on the North Shore

The project required distinct comfort for each living space, without multiplying outdoor amenities.
Thanks to a combination of ducted and wall-mounted units, the Mini-VRF offered a clean, quiet and scalable solution, while respecting interior aesthetics.


Common mistakes that we systematically avoid

  • Underestimating the actual heating needs for cold climates.

  • Neglecting the cumulative lengths of piping and their impact on performance.

  • Choosing indoor units that are poorly suited to the actual use of the spaces.

  • Installing a complex system without a clear plan for future maintenance.

At AirGreen , each project begins with a complete technical analysis : thermal loads, building configuration, electrical constraints, occupancy habits and long-term objectives.


Why entrust a Mini-VRF project to AirGreen

  • Certified refrigeration technicians , specializing in VRF and Mini-VRF systems.

  • Transparent approach : detailed submission before work begins, no surprises.

  • Expertise in grant programs in Montreal , Laval , Longueuil , North Shore and South Shore .

  • Structured after-sales service , essential for advanced HVAC systems.

  • Concrete experience , based on real installations, not on theoretical configurations.


Conclusion

The FUJITSU AIRSTAGE J-7S VRF R32 – 48,000 BTU represents a coherent, robust HVAC solution adapted to the realities of Quebec. Its flexibility, heating performance, and compact design make it a strategic choice for buildings where comfort, reliability, and energy efficiency are non-negotiable.

For a personalized analysis , a detailed quote or a feasibility study for your project in Montreal , Laval , Longueuil , on the North Shore or the South Shore , contact AirGreen Heat Pumps, Air Conditioning & Heating directly.
We support you from design to installation, with proven HVAC expertise tailored to your specific situation.