ADP

ADP HE21C24A155A0004R Evaporator A-Coil | 2 Tons

In stock

The ADP HE21C24A155A0004R 2-ton R-454B uncased coil sits on your furnace and, matched with a matching ADP outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberHE21C24A155A0004R

2 tons24,000 BTU/h nominal
15-1/2 inwidth
R-454Brefrigerant
R-454BAdd-on heat pumpUncasedR-454B
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberHE21C24A155A0004R
ManufacturerADP
Size2 tons
Width15-1/2 in
RefrigerantR-454B
MeteringTXV à purge (bleed) HP-A/C, R-454B

HE21C24A155A0004R: the two-ton ADP coil that fits a 15-1/2 in furnace

A technician arrives at your home, opens the furnace plenum and takes out a tape measure. The number that matters most is not the capacity but the width: 14 in or 15-1/2 in? The ADP HE21C24A155A0004R coil answers the second measurement. It is an uncased two-ton coil, 24,000 BTU/h nominal, with R-454B refrigerant, built for furnaces whose opening is larger than the usual size.

Why width matters so much

A coil that is too narrow lets air slip past its tubes: part of the airflow bypasses the heat exchange, and you pay for cooling that never arrives. A coil that is too wide simply does not fit. In between, an insulated transition can be built, but it is extra work, with joints to seal and insulation to get right.

With its 15-1/2 in width, this model often avoids that step on wider furnaces. It measures 13 in high and 19-1/2 in deep, and weighs 20 lb net. If your furnace opening is 14 in, look instead at the HE21C24A140A0004R, identical in capacity and height.

A visit to measure, not to guess

We do not like to order before seeing the site. On location, we record the plenum width, the available height, the drain location and the access for piping. We also check the electrical service and the blower. Only then do we choose the model, and we confirm it with the AHRI number of the complete pairing.

In Montreal, Laval and Longueuil, as on the North Shore and the South Shore, these measurements vary from one street to the next, because furnaces were installed in very different eras.

What two tons means for your home

A capacity of two tons is meant for homes of average size. It is determined after a load calculation: insulation, windows, orientation, number of occupants. A size that is too generous causes repeated shutdowns and air that stays humid; a size that is too tight never catches up with the heat of a July afternoon.

The nominal airflow is 800 CFM, which the furnace blower must deliver. Clean filters and ductwork without restrictions help a great deal.

Installation and positions

The A-coil sits on the furnace, in the plenum or in a cabinet made to measure. ADP rates it as multi-position: upflow, horizontal left or right, or downflow according to its downflow airflow table. The suction connection is 3/4 in ODF, and the drain has two 3/4 in FPT outlets, front left and front right.

An HP-A/C bleed TXV for R-454B regulates the refrigerant supply according to the thermal load.

Built-in leak detection

The coil comes with the RDS system, installed at the factory with its controller and sensor (code R). If the sensor detects refrigerant, the thermostat's 24 V circuit opens: the compressor and heating stop, and the fan stirs the air. It keeps running for 7 min after the reading returns below the threshold.

Choosing between this model and the others in the series

Here is how we reason it through with customers:

  • HE21C18A140A0004R: 1.5 tons and 14 in; for small volumes;
  • HE21C24A140A0004R: two tons, 14 in; the same capacity as this one, but for a narrower furnace;
  • HE21C24A155A0004R (this one): two tons, 15-1/2 in;
  • HE30C24A140A0004R: two tons, 14 in, reduced height for a low plenum;
  • HE30C24A155A0004R: two tons, 15-1/2 in, with reduced height as well.

The rule is simple: capacity first, width second, height last. The model presented here suits a wide furnace where height is not a restriction.

The coil is not sold on its own

Because it uses R-454B, it is matched with an ADP outdoor unit of the same capacity and the same refrigerant, installed along with it. Efficiency, published as SEER2, EER2 and HSPF2 ratings, belongs to that certified pair, not to the coil. We therefore check the pairing before any order, so that you get the ratings you were promised.

Add-on heat pump: what you gain

With a heat pump, the home is heated by moving heat from outside to inside. In mild weather, you get two to three times more heat than the energy consumed. When the mercury plunges, the furnace takes over. During summer, the same equipment cools every room at once.

Installation, warranty and licence

AirGreen, a family-run heating and cooling company based in Montreal for more than fifteen years, operates under RBQ licence 5645-9605-01. We take care of:

  • fitting the coil and sealing the connections;
  • the outdoor unit, brazed piping, the nitrogen test and evacuation;
  • the drain, the thermostat, commissioning and an explanation of how it works.

The manufacturer's warranty lasts 5 years from installation, capped at 6 years after manufacture; a 10-year limited warranty is available on registration.

Points to confirm before ordering

  • the actual width of the furnace: 15-1/2 in for this model;
  • R-454B refrigerant, on both the indoor and outdoor sides;
  • the capacity of the blower;
  • the home's load calculation.

The typical case of a wider furnace

Large-size furnaces are often found in homes whose heating system was replaced once before with a bulkier unit. The plenum is more generous there, but the original ducts remain. A 14 in coil would then leave a gap on each side; this one closes the gap and directs the air where it needs to go.

The homeowner gets a system that looks cleaner, fewer insulation patches and, above all, a heat exchange that uses the full surface of the tubes rather than only a portion.

Maintaining a well-installed system

After commissioning, the steps are simple: clean filter, free drain, thermostat set to the right season. Have the whole system checked once a year. A fouled pan or a forgotten filter shows up as water leaks or as frost on the coil, two signs that deserve a call.

We stay reachable after the installation, and we hand over a summary of the settings so that you can find the information the day it has to be given to another technician.

Why choose ADP for this job

ADP makes coils and blower cabinets that several heating and cooling brands sell under their own names. The HE line was designed for R-454B, with a TXV expansion valve and a built-in detection system. For an installer, that is an advantage: the parts in the series look alike, the connections are predictable and the documentation is complete.

Incentives

Hydro-Québec's assistance depends on the complete system. We check the official list, taking the installation date into account, then tell you what applies.

Take the next step

Request your free on-site estimate: we measure the furnace, examine the electrical service and give you a written quote for the complete ADP system. Financing is available to spread out the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The HE21C24A155A0004R sits in the plenum of a furnace or air handler. Connected to a matching ADP outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with a matching ADP outdoor unit
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerADP
ModelHE21C24A155A0004R
TypeUncased evaporator coil
LineHE
Nominal size2 tons (24,000 BTU/h)
RefrigerantR-454B
Metering deviceTXV à purge (bleed) HP-A/C, R-454B
Suction connection3/4 in ODF
Airflow800 CFM
Dimensions W × H × D15-1/2 × 13 × 19-1/2 in
Net weight20 lb
Model numberHE21C24A155A0004R
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 15-1/2 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
ADP
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 2-ton ADP coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.