ADP HE30C24A155A0004R Evaporator A-Coil | 2 Tons
The ADP HE30C24A155A0004R 2-ton R-454B uncased coil sits on your furnace and, matched with a matching ADP outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberHE30C24A155A0004R
514 316-2973 · sales@airgreen.ca
Quick facts
HE30C24A155A0004R: 15-1/2 in wide, 11 in low, a two-ton ADP coil
Some furnaces are wide and yet squeezed under a low ceiling. If that is your case, a standard coil is hard to fit. The HE30C24A155A0004R combines two features that the other models in the series do not add together: 15-1/2 in of width and 11 in of height, with 19-1/2 in of depth. Nominal capacity: two tons, 24,000 BTU/h, with R-454B refrigerant.
An identity card in a few lines
- manufacturer: ADP, HE line, uncased evaporator coil;
- dimensions W × H × D: 15-1/2 × 11 × 19-1/2 in;
- net weight: 22 lb;
- nominal airflow: 800 CFM;
- expansion valve: HP-A/C bleed TXV for R-454B;
- suction connection: 3/4 in ODF;
- drain: two 3/4 in FPT outlets, front left and front right.
Three scenarios where it fits just right
First case: a plex in Montreal whose basement was partitioned after the fact, with a wide furnace and tight clearance above. Second case: a bungalow in Laval where an electric furnace at the end of its life must become a central heat pump without touching the joists. Third case: a home in Longueuil or on the South Shore where the old, taller coil forced someone to rig up a makeshift cabinet.
In each of these cases, the same question comes up: what is the width of the opening, and how much height is left? If both answers match this size, the decision is made quickly.
If the furnace is not quite this size
A gap is not an obstacle. We build an insulated transition on site that connects the coil to the existing opening. It is a common step in renovation. It takes insulation, sealed joints and a bit of time, but it avoids redoing the whole plenum.
Our visit serves to decide between the model as is and the model with a transition. We also check that the blower can deliver the nominal airflow.
How it works, from refrigerant to drain
The cooled liquid arrives from the outdoor unit, passes through the expansion valve and evaporates in the tubes. The air passing through gives up its heat, and the condensed water runs to one or the other of the drain outlets. In winter, with a heat pump, the exchange is reversed: the air of the house is warmed on contact with the coil. The furnace serves as backup when the outdoor temperature drops below the threshold chosen together.
ADP rates this coil as multi-position: upflow, horizontal left or right, or downflow according to the manufacturer's downflow airflow table.
The sensor that watches over the R-454B
A refrigerant detection system is mounted at the factory, with a controller and a sensor (code R). As soon as it senses a leak, it cuts the 24 V thermostat power: the compressor and heating stop, and the fan runs to disperse the refrigerant. It keeps going for 7 more min once the reading has returned below the threshold.
Selection chart for the series
Here is how this model stands against the other four:
- HE21C18A140A0004R: 1.5 tons and 14 in wide, for small loads;
- HE21C24A140A0004R: two tons, 14 in wide, taller body;
- HE21C24A155A0004R: two tons, 15-1/2 in wide, taller body;
- HE30C24A140A0004R: two tons, low profile, but only 14 in wide;
- HE30C24A155A0004R: two tons, low profile and 15-1/2 in wide; this is the one.
Choose the latter when both constraints are present at once. If only width matters, a taller model is enough; if only height matters, the 14 in model is suitable.
The required pairing with the outdoor unit
This coil has no efficiency rating of its own. The published ratings belong to the certified system, that is, the coil and an ADP outdoor unit of the same capacity and the same refrigerant. Before ordering, we find the AHRI number of the pairing and confirm it. That number is what lets you compare two quotes fairly.
What changes in the home
In mild weather, a heat pump produces two to three times more heat than the electricity it takes in. The gain shrinks in a hard freeze, and the furnace then takes over. In summer, you enjoy cool, drier air in every room, thanks to the ducts already in place.
The AirGreen installation
AirGreen is a family-run heating and cooling company based in Montreal for more than fifteen years, under RBQ licence 5645-9605-01. We also serve the North Shore. The work includes:
- recording the dimensions, the blower and the electrical panel;
- fitting the coil and sealing the joints;
- the outdoor unit, brazed piping, the nitrogen test and evacuation;
- the drain, the thermostat, commissioning and the demonstration.
Manufacturer's warranty: 5 years from installation, up to 6 years after manufacture, with a 10-year limited warranty on registration.
Before you decide
- furnace width: 15-1/2 in;
- clear height: 11 in;
- R-454B refrigerant indoors and outdoors;
- a blower capable of the required airflow.
Why the wide-and-low combination is less common
Most coils come in either a width or a height, rarely both at once. In this series, the models split into two widths and two heights: this one is the only one to marry 15-1/2 in and 11 in. For the installer, it avoids having to choose between a wide transition and raising the plenum.
This size weighs 22 lb net, like its 14 in neighbour of the same height. It is heavier than the taller models, but it is still easy for two people to carry.
When another model is the better choice
Let us be frank: this coil is not always the right one. If your plenum offers height, a taller model will do just as well and will sometimes be simpler to install. If your furnace is narrow, the 14 in version avoids a transition. And if the home is small, the 1.5-ton model in the series may control summer humidity better. Our role is to say so before the order, not after.
After installation: a few simple steps
Change the filter regularly, keep the drain outlets clear and schedule an annual check of the system. After commissioning, we give you a written summary of the settings, including the winter switchover threshold to the furnace, which we can adjust with you over the seasons.
What we explain on site
On commissioning day, we go over the thermostat with you, the location of the filter, the expected behaviour of the leak sensor and how to shut the system down if in doubt. We also answer questions about normal noises, about the drain water and about the first weeks of use. A successful installation also means a homeowner who is comfortable with the equipment.
Hydro-Québec incentives
Eligibility depends on the complete system and not on the coil alone. We check the official list at the time of the quote, according to the installation date.
Get your quote
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete ADP system. Financing is available to spread out the cost of the project.
The heat pump coil for your furnace
The HE30C24A155A0004R sits in the plenum of a furnace or air handler. Connected to a matching ADP outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching ADP outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 15-1/2 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
ADPSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 2-ton ADP coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.