ADP HE32C36A155A0004R Evaporator A-Coil | 3 Tons
The ADP HE32C36A155A0004R 3-ton R-454B uncased coil sits on your furnace and, matched with a matching ADP outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberHE32C36A155A0004R
514 316-2973 · sales@airgreen.ca
Quick facts
A home visit with the HE32C36A155A0004R: ADP 3-ton coil, 15-1/2 in wide, 15 in high
The best way to understand an evaporator coil is to follow what happens on the day we come to measure it at your home. The HE32C36A155A0004R is an ADP uncased A-coil rated at 3 tons (36,000 BTU/h), using R-454B refrigerant. Here is how a typical visit goes, followed by the reasons this model turns up often in our quotes.
Arrival: we look at the furnace first
The technician starts in the basement. He locates the furnace or blower cabinet, removes the plenum access panel and notes the width of the opening. If it is close to 15-1/2 in, the HE32C36A155A0004R goes on the list of candidates. That figure is the same as for several other models in the series, which is why width alone does not decide.
The technician then measures the vertical space. This model is 15 in high and 19-1/2 in deep, and weighs 28 lb. It goes in without a crane or scaffolding, but there must be room to handle it, to connect it and to bring out the 3/4 in ODF suction line.
Second stop: the electrical panel and the outdoor unit location
The outdoor unit goes on the ground or on a bracket, away from ice falling off the roof. We check the distance to the coil, the route of the piping and the capacity of the electrical panel. This step is not about the coil itself, but it shapes the quote, because the system works as a pair.
What the coil does once installed
The coil sits in the path of the air, between the furnace blower and the ducts. In summer, it cools and dries the air. The condensate falls into the pan and flows out through one of the two 3/4 in FPT drain connections, front left or front right. In winter, with a heat pump, it distributes the heat captured outdoors.
Technical data
- Model: HE32C36A155A0004R, ADP HE line.
- Type: A-shaped evaporator coil, uncased.
- Size: 3 tons (36,000 BTU/h).
- Dimensions W × H × D: 15-1/2 × 15 × 19-1/2 in; net weight: 28 lb.
- Refrigerant: R-454B; HP-A/C bleed TXV expansion valve.
- Nominal airflow: 1,200 CFM.
- Positions: upflow, horizontal left or right, downflow per ADP's downflow airflow chart.
How this model compares with its siblings
When deciding, we always ask three questions: what width, what height, what weight? This model answers "15-1/2 in" to the first.
- If the furnace is narrow, we look at the HE32C36A140A0004R or the HE33C36A140A0004R, at 14 in.
- If it is wide, the HE32C36A170A0004R, like the HE23C36A170A0004R, HE33C36A170A0004R and HE35C36A170A0004R, is 17 in.
- For the same 15-1/2 in width, there are the HE23C36A155A0004R, HE33C36A155A0004R, HE35C36A155A0004R and HE36C36A155A0004R. Their height or weight differs from that of the HE32C36A155A0004R; the space available above your furnace settles it.
Keep in mind that the size, the refrigerant and the expansion valve are identical across the series. The choice comes down to the footprint.
The match, piece by piece
A coil is not sold without an outdoor unit. This one is paired with an ADP unit of the same capacity and the same refrigerant. The SEER2, EER2 and HSPF2 ratings shown on the data sheets belong to the pair, not to the coil. An AHRI number links the two elements. We confirm it before the order, so that a quote never advertises an efficiency that would not match the combination actually installed.
On the day of the work
- Final check of the measurements, the blower and the electrical panel.
- Setting the coil in the plenum, with an insulated transition built on site if there is a width gap, and sealed duct connections.
- Placing the outdoor unit, brazed piping, nitrogen leak test, evacuation.
- Connecting the drain and the thermostat.
- Start-up, airflow adjustment and a demonstration.
Our crews are based in Montreal and travel to Laval, Longueuil, the North Shore and the South Shore. The work is done under our RBQ licence 5645-9605-01.
Built-in leak detection
The manufacturer has factory-mounted a refrigerant controller and sensor (code R). When the sensor detects a leak, the thermostat loses its 24 V power; the compressor and the heating stop, the fan starts to stir the air, and it keeps running for 7 min after the level returns below the threshold. It is automatic, not a setting.
The furnace keeps a role
In an "add-on" installation, the furnace keeps its blower, its filters and its heating elements. When the outdoor temperature falls below the agreed threshold, it takes over. This split avoids oversizing the heat pump for the few very cold days of the year.
Warranty
The manufacturer covers the unit for 5 years from installation, with a maximum of 6 years after manufacture. A 10-year limited warranty is available with registration.
Three questions we get during the visit
Can it also heat? Yes, if the outdoor unit is a heat pump: the house is cooled in summer and heated in winter. With a simple central air conditioner, it only cools.
Can my old air conditioner stay? Generally not. The coil runs on R-454B and requires the outdoor unit specified by the manufacturer. We install the complete system so that everything is compatible.
What if my furnace is not the same width? We measure and, if needed, build an insulated transition on site. It is a routine operation for us and it does not compromise the durability of the assembly.
What it changes in daily life
After installation, the difference shows mostly in July. The air circulates through the same registers as the heating, the house dries out and the noise of window air conditioners disappears. In winter, the heat pump provides most of the heat, and the furnace simply takes over at the lowest temperatures. You still have a single thermostat: you set the house, not two devices.
The bill follows the same logic. An electric furnace turns every kilowatt-hour into an equal amount of heat, whereas a heat pump moves heat and delivers two to three times more in mild temperatures. The colder it gets, the more that advantage shrinks, which is why the furnace stays as backup.
To check before ordering
- The coil and the outdoor unit both run on R-454B.
- The published ratings apply to the certified match.
- The furnace must have the right width and blower; we confirm them on site.
- The space above the furnace must accept the height of the coil.
Financial help
Hydro-Québec incentives, such as LogisVert, depend on the complete system. We check the official list at the time of the quote, based on the installation date, then explain what applies to your file.
End of the visit: estimate and financing
At the end of the visit, you receive a written quote for the complete ADP system. The estimate is free. If you would like to spread the expense, financing is available. For the next step, just tell us the date that suits you.
The heat pump coil for your furnace
The HE32C36A155A0004R sits in the plenum of a furnace or air handler. Connected to a matching ADP outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching ADP outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 15-1/2 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
ADPSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 3-ton ADP coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.