ADP HE36C36A155A0004R Evaporator A-Coil | 3 Tons
The ADP HE36C36A155A0004R 3-ton R-454B uncased coil sits on your furnace and, matched with a matching ADP outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberHE36C36A155A0004R
514 316-2973 · sales@airgreen.ca
Quick facts
HE36C36A155A0004R: the ADP 3-ton coil for tall plenums (23 in), built to last, easy to maintain and well covered by warranty
Some homeowners are not looking for the cheapest quote; they are looking for equipment they will not have to think about for a long time. The ADP HE36C36A155A0004R evaporator coil, rated at 3 tons (36,000 BTU/h), A-shaped, uncased, using R-454B, suits that way of seeing things. At 23 in high and 41 lb, it is among the most substantial models in the series, with a width of 15-1/2 in. This page covers what you need to know for it to work well for a long time: matching, expansion valve, drain, warranty and maintenance.
The measurements to know
- Dimensions W × H × D: 15-1/2 × 23 × 19-1/2 in.
- Net weight: 41 lb.
- Size: 3 tons (36,000 BTU/h), ADP HE series.
- Refrigerant: R-454B.
- Nominal airflow: 1,200 CFM.
- Suction: 3/4 in ODF.
- Condensate: two 3/4 in FPT connections, front left and front right.
- Positions: multiposition, meaning upflow, or horizontal left or right; downflow following the ADP downflow airflow chart.
A coil of this height needs a suitable plenum and free space. We always confirm it with a measurement, because the 41 lb weight takes two people to handle on a narrow staircase.
The expansion valve: the part that works in silence
The HE36C36A155A0004R is equipped with an HP-A/C bleed TXV expansion valve, designed for R-454B. Its role is to meter the refrigerant entering the coil according to the load, so that the system does not wear itself out during periods of varying demand. For a homeowner, this means steadier airflow from the registers, without having to touch anything.
The warranty, explained simply
The manufacturer offers 5 years from installation, with a cap of 6 years after manufacture. There is also a 10-year limited warranty offered with registration. In practice, that means two things: the installation date counts, and registration does not happen by itself. We help you do it when we hand over the system, and we keep your documents to avoid unpleasant surprises.
The maintenance that preserves the coil
- A clean filter, checked regularly, to keep the airflow close to its nominal value.
- A clear pan and drain: a blocked drain is the first cause of water in the basement.
- An outdoor unit kept clear of snow, leaves and debris.
- A phone call as soon as a noise or behaviour surprises you, without waiting.
These steps are simple and need no tools. For the rest, refrigeration and electrical work are the business of qualified technicians, under RBQ licence 5645-9605-01 at AirGreen.
The HE36C36A155A0004R among the other models in the series
It shares with the others the 3-ton size, R-454B and the expansion valve. It differs by footprint.
- Same 15-1/2 in width: HE23C36A155A0004R, HE32C36A155A0004R, HE33C36A155A0004R and HE35C36A155A0004R. These models have different heights and weights; this one is the tallest in this group.
- 17 in width: HE23C36A170A0004R, HE32C36A170A0004R, HE33C36A170A0004R and HE35C36A170A0004R.
- 14 in width: HE32C36A140A0004R and HE33C36A140A0004R.
The HE36C36A155A0004R suits a furnace with a 15-1/2 in opening and a tall plenum. If you lack vertical clearance, we move to a lower model of the same width.
Why installation quality matters as much as the model
A well-made coil can disappoint if it is poorly installed. Poorly sealed duct connections let air leak out, badly brazed piping lets refrigerant escape, and a poorly sloped drain ends up overflowing. That is why we leak test with nitrogen, pull a vacuum and set the airflow before leaving: these steps determine the real lifespan of the whole assembly, far more than a number on a data sheet.
The manufacturer's warranty covers the unit; the quality of the job is our responsibility. We encourage you to keep the invoice, the system sheet and the AHRI number in a single file.
For what type of home
This model appeals to owners of a cottage or a multi-storey house in Laval, Longueuil or the North Shore whose mechanical room offers height. It also suits anyone who plans to stay in their house for a long time and prefers a system installed once, with a complete file, over a temporary solution. If your plenum is low or your staircase tight, we will tell you honestly and propose a more compact model.
Leak detection and safety
The refrigerant detection system (RDS) is installed at the factory, with a controller and a sensor. If a leak is spotted, the thermostat's 24 V power is cut, the compressor and the heating stop, and the fan runs during the leak and for another 7 min after the level returns below the threshold.
Matching, AHRI and efficiency
This coil is matched with an ADP outdoor unit of the same capacity and the same refrigerant. It has no efficiency rating of its own: SEER2, EER2 and HSPF2 attach to the certified system, linked by an AHRI number. We confirm that number in the AHRI directory before ordering.
What the coil does in the house
Set on the furnace or the blower cabinet, it cools and dries the air in summer, while the condensation water flows out through the drain. With a heat pump, it also passes heat from outdoors to the house air in winter. The furnace keeps its blower, its filters and its heating elements, and takes over below the temperature threshold programmed with you.
Our installation, step by step
- Measuring the furnace, checking the blower and the electrical panel.
- Setting the coil in the plenum, sealing the duct connections, building a transition on site if needed.
- Outdoor unit on a pad or bracket, brazed piping, nitrogen leak test, evacuation.
- Condensate drain and thermostat.
- Start-up, airflow adjustment and an explanation of how the system works.
We work in Montreal, Laval, Longueuil, and on the North Shore and South Shore.
To confirm before buying
- R-454B for the coil as well as for the outdoor unit.
- The published ratings apply to the certified match.
- The 15-1/2 in width and the 23 in height compatible with your furnace and your plenum.
- The blower must deliver the system's airflow.
Hydro-Québec incentives
Programs such as LogisVert are tied to the complete system, not to the coil taken in isolation. We check the official list based on the installation date and tell you what applies to your project.
Free estimate and financing
We measure the furnace, check the electrical service and give you a written quote for the complete ADP system. Financing is available to spread the cost of the project.
The heat pump coil for your furnace
The HE36C36A155A0004R sits in the plenum of a furnace or air handler. Connected to a matching ADP outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching ADP outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 15-1/2 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
ADPSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 3-ton ADP coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.