ADP

ADP HE35C48A200A0004R Evaporator A-Coil | 4 Tons

In stock

The ADP HE35C48A200A0004R 4-ton R-454B uncased coil sits on your furnace and, matched with a matching ADP outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberHE35C48A200A0004R

4 tons48,000 BTU/h nominal
20 inwidth
R-454Brefrigerant
R-454BAdd-on heat pumpUncasedR-454B
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberHE35C48A200A0004R
ManufacturerADP
Size4 tons
Width20 in
RefrigerantR-454B
MeteringTXV à purge (bleed) HP-A/C, R-454B

ADP HE35C48A200A0004R coil: 4 tons and 20 in wide for furnaces with some width to them

Some furnaces have a wide plenum, often those in large two-storey homes or in bungalows with a finished basement. For them, a coil that is too narrow forces improvised connections. The HE35C48A200A0004R was designed differently: its 20 in width matches these plenums, and its 4-ton capacity (48,000 BTU/h) follows the airflow that these homes call for.

Here, in question form, is what homeowners in Montreal, Laval, Longueuil, the North Shore and the South Shore ask us most often about it.

My furnace is wide: is this coil right for it?

That is exactly its niche. At 20 in, it comes close to the width of more generous furnaces and limits the need for a transition. If yours is a little narrower, we build an insulated connecting piece on site; a difference in size is never a reason to give up.

Its dimensions W × H × D are 20 × 21 × 19-1/2 in. It weighs 39 lb net, which is still reasonable to handle on a basement staircase.

What does "uncased" mean?

The coil arrives bare, without the metal shell that usually surrounds it. It sits in the furnace plenum, or in a cabinet that we build as needed. For you, this means the existing shell is reused when it is in good shape, instead of paying for one more enclosure.

Can it be used for heating?

Yes, provided it is paired with a heat pump. In summer, it cools and dries the air; in winter, the cycle reverses and the heat captured outdoors is delivered through the same vents. With a simple central air conditioner, it only provides cooling. The furnace keeps its backup role for the coldest days, according to the temperature threshold that we program together.

Can I keep my current air conditioner?

Generally not. This coil runs on R-454B refrigerant and must be connected to the outdoor unit specified by the manufacturer, of the same capacity. We therefore install both parts together; this is what makes a certified match possible, with an AHRI number that we confirm before the order.

The features of the HE35C48A200A0004R, point by point

Here is what the manufacturer publishes for this model in the HE line.

  • Capacity: 4 tons, 48,000 BTU/h nominal.
  • Refrigerant: R-454B.
  • Expansion device: HP-A/C bleed TXV, set for R-454B.
  • Nominal airflow: 1,600 CFM.
  • Suction line: 7/8 in ODF.
  • Condensate drainage: two 3/4 in FPT outlets, one at the front left and the other at the front right; we choose the more practical side for your basement.
  • Positions: multi-position (upflow, horizontal left or right), with an ADP downflow airflow table for the downflow configuration.
  • Warranty: 5 years from installation, to a maximum of 6 years after manufacture; a 10-year limited warranty is available on registration.

The refrigerant detection system, explained simply

The letter R at the end of the model number indicates that the controller and the leak sensor are factory-mounted. If the sensor detects refrigerant, it cuts the 24 V power from the thermostat. The compressor and the heating then stop working, while the fan starts running. Once the level is acceptable again, the fan keeps running for another 7 min before stopping. You have nothing to program: it is a safety net that is part of the unit.

The 20 in HE35: does it stand out from its three neighbours?

Four 4-ton coils make up this series, all using R-454B, all uncased, all with the same bleed TXV expansion device. Only two criteria separate them: the width and the size of the line code.

  • The HE35C48A170A0004R is 17 in wide, a choice for furnaces of common size.
  • The HE35C48A200A0004R, the one on this page, is 20 in wide and aimed at wider plenums.
  • The HE36C48A170A0004R is 17 in wide, with a taller and slightly heavier body than the HE35.
  • The HE36C48A200A0004R combines a 20 in width with that taller body.

A simple rule: start from the width of the furnace, then check the height available in the plenum. If you have some vertical space, an HE36 model remains possible; if clearance is tight, the 20 in HE35 keeps the advantage.

What our job includes for a coil of this size

A 4-ton coil moves a lot of air, which is why the blower and the connections deserve as much attention as the coil itself. Our work list includes:

  • measuring the furnace, checking the blower and a look at the electrical panel;
  • installing the coil in the plenum, with an insulated transition if the width requires it, and sealing the air joints;
  • setting the outdoor unit on a pad or bracket, brazed piping, the nitrogen leak test and then the vacuum;
  • connecting the condensate drain and the thermostat;
  • start-up, airflow adjustment and a demonstration at your home.

Why a heat pump changes the bill for a large home

In a large home, baseboard or electric furnace heat weighs heavily on the winter bill, because every kilowatt-hour becomes exactly one kilowatt-hour of heat. A heat pump, on the other hand, carries heat from outside to inside; in mild weather, it delivers more heat than the electricity it uses. The colder it gets, the weaker that ratio becomes, and the furnace then goes back to work. The result: a large part of the season is covered by the heat pump, and the backup steps in only for the harshest days.

In summer, the same coil replaces several window air conditioners with a single outdoor unit. The upstairs bedrooms and the basement receive the same cool air through the existing vents.

What a coil does not tell you about efficiency

This coil has no efficiency rating of its own. The ratings shown in a quote describe the matched system, never an isolated part. That is why we always require the AHRI number of the match: it allows an honest comparison of two offers and also serves as a reference when applying for an incentive.

Before signing, check these four things

  • Does the 20 in width fit the furnace, or should a transition be planned?
  • Is the blower able to deliver the system's airflow?
  • Does the proposed outdoor unit really use R-454B?
  • Does the quote show the AHRI number of the complete system?

Financial assistance

Incentives depend on the complete system. We consult the official Hydro-Québec list according to the installation date and tell you what is eligible in your case, without promising an amount that we cannot confirm.

Book an appointment for an estimate

We travel to measure the furnace, check the electrical service and give you a written quote for the complete ADP system. To spread out the expense, see our financing page.

A local team, one visit to sort everything out

AirGreen is a family-run heating and cooling company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is covered by our RBQ licence 5645-9605-01. From measuring to the final adjustment, our technicians take care of the HE35C48A200A0004R and its outdoor unit, anywhere in Greater Montreal.

01 · What it is for

The heat pump coil for your furnace

The HE35C48A200A0004R sits in the plenum of a furnace or air handler. Connected to a matching ADP outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with a matching ADP outdoor unit
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerADP
ModelHE35C48A200A0004R
TypeUncased evaporator coil
LineHE
Nominal size4 tons (48,000 BTU/h)
RefrigerantR-454B
Metering deviceTXV à purge (bleed) HP-A/C, R-454B
Suction connection7/8 in ODF
Airflow1,600 CFM
Dimensions W × H × D20 × 21 × 19-1/2 in
Net weight39 lb
Model numberHE35C48A200A0004R
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 20 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
ADP
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 4-ton ADP coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.