ADP HE36C48A200A0004R Evaporator A-Coil | 4 Tons
The ADP HE36C48A200A0004R 4-ton R-454B uncased coil sits on your furnace and, matched with a matching ADP outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberHE36C48A200A0004R
514 316-2973 · sales@airgreen.ca
Quick facts
HE36C48A200A0004R, the largest size in the series: 20 in wide, 23 in tall, 4 tons
Among the four uncased 4-ton coils in this ADP series, the HE36C48A200A0004R combines the greatest width (20 in) and the tallest body (23 in). It weighs 41 lb net. Using R-454B, it sits on a furnace or a blower cabinet and pairs with an ADP outdoor unit of the same capacity, that is 4 tons or 48,000 BTU/h nominal.
Rather than rolling out a spec sheet right away, let's follow this coil through a year in a home in Montreal, Laval, Longueuil, the North Shore or the South Shore. You understand what a coil is for better when you watch it work through the seasons.
Spring: the visit and the match
The mild shoulder season is ideal for planning, because neither heating nor cooling is pressing. A technician measures the furnace, examines the plenum and checks whether the blower can deliver the system's airflow. For a coil of this size, we look in particular at the vertical and lateral space, because it is both wide and tall.
We also look up the exact match with the outdoor unit in the AHRI directory. The number obtained becomes the reference for the quote.
Summer: cool air in every room
During heat waves, the refrigerant evaporates in the tubes of the coil and absorbs heat from the air passing through. The moisture condenses, drops into the pan and runs to the drain, since the HE36C48A200A0004R has two 3/4 in FPT connections, at the front left and the front right. The result: the air distributed is cooler and less muggy, in the bedrooms as in the basement.
Fall: fine-tuning before the first cold
This is the time to program the switchover point between the heat pump and the furnace. We set it with you according to the insulation of the house and your tolerance for cold. Nothing prevents changing it later.
Winter: the heat pump takes over
The cycle reverses. The refrigerant warmed by the outdoor unit gives up its heat to the air passing through the coil, and your existing vents blow warm air. During periods of intense cold, the furnace becomes the backup again: it keeps its blower, its filters and its heating elements, and goes to work below the agreed threshold.
This coil alone has no efficiency rating. The published ratings describe the matched system and its AHRI number.
What we check before choosing this size
- The furnace is wide enough to take 20 in without a transition, or we build one, insulated, on site.
- The 23 in height fits in the plenum or the blower cabinet.
- The blower provides the required airflow; otherwise comfort suffers.
- The outdoor unit uses R-454B like the coil.
- The complete system appears on the official Hydro-Québec list on the installation date.
The manufacturer's data in brief
- Line: HE, uncased evaporator coil;
- Nominal size: 4 tons (48,000 BTU/h);
- Dimensions W × H × D: 20 × 23 × 19-1/2 in;
- Net weight: 41 lb;
- Expansion device: HP-A/C bleed TXV, R-454B;
- Nominal airflow: 1,600 CFM;
- Suction: 7/8 in ODF;
- Warranty: 5 years from installation, 6 years maximum after manufacture; 10 years limited on registration;
As for orientation, the coil is multi-position: it can be placed upflow or horizontal, left or right side. For a downflow installation, we refer to ADP's downflow airflow table.
Built-in leak detection
A controller and a sensor, factory-mounted, form the refrigerant detection system (RDS), identified by the R code. If it detects refrigerant, it cuts the 24 V power from the thermostat: the compressor and the heating stop, while the fan runs. After the level returns below the threshold, it runs for another 7 min.
The HE36C48A200A0004R compared with the other three coils
Here is the comparison, straight up. The four models share the 4-ton capacity, R-454B refrigerant, the absence of a cabinet and the same type of expansion device.
- HE35C48A170A0004R: 17 in wide, shorter and lighter body. The most compact of the four.
- HE35C48A200A0004R: 20 in wide, shorter body.
- HE36C48A170A0004R: 17 in wide, tall body.
- HE36C48A200A0004R (this page): 20 in wide, tall body.
The 20 in HE36 is therefore the one that needs the most space. If the furnace is wide and height is not a problem, it fits well. If vertical space is limited, the 20 in HE35 does the same job with a lower profile. If the furnace is narrow, a 17 in model, with or without a transition, will be a better fit.
Can the old air conditioner be kept?
In principle, no. The coil runs on R-454B and pairs with the outdoor unit specified by the manufacturer, installed at the same time. We install the complete system, from the coil to the brazed piping, including the nitrogen test and the vacuum.
Why keep the furnace when adding a heat pump
Many homeowners think everything has to be replaced. That is not the case. The furnace remains useful: it supplies the blower that pushes the air, the filters that clean it and the heating elements that take over in extreme cold. The coil is inserted in the plenum and completes the assembly, which limits the scope of the work and avoids touching the ducts.
For a large home, this approach keeps the distribution network as it is, with its vents and returns, while the source of heating and cooling is renewed.
Frequently asked questions about this model
Does the coil heat on its own? No. It heats only when a heat pump sends it hot refrigerant; with a central air conditioner, it only cools.
My furnace has a different width, what should I do? We measure it, then build an insulated transition on site if necessary.
Do incentives apply to the coil? They apply to the complete system, never to the part alone.
Incentives
Eligibility for Hydro-Québec programs depends on the matched system, not on the coil taken alone. We check the official list according to the installation date, then tell you what applies to your project.
A free estimate, then financing
We come to your home to measure the furnace, check the electrical service and write a quote for the complete ADP system. If you wish to spread out the cost, see the financing available.
AirGreen, from the spring visit to winter service
AirGreen is a family-run heating and cooling company based in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 for refrigeration, ventilation and electrical work. We install the HE36C48A200A0004R and its outdoor unit in Montreal, Laval, Longueuil, the North Shore and the South Shore.
The heat pump coil for your furnace
The HE36C48A200A0004R sits in the plenum of a furnace or air handler. Connected to a matching ADP outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching ADP outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 20 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
ADPSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 4-ton ADP coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.