AMERISTAR 4MXCA001AC6HCA Evaporator A-Coil | 1.5 to 2.5 Tons

In stock

The Ameristar 4MXCA001AC6HCA 1.5 to 2.5-ton R-410A cased coil sits on your furnace and, matched with a matching Ameristar outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model number4MXCA001AC6HCA

1.5 to 2.5 tons30,000 BTU/h nominal
14-1/2 inwidth
R-410Arefrigerant
R-410AAdd-on heat pumpCasedR-410A
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model number4MXCA001AC6HCA
ManufacturerAmeristar
Size1.5 to 2.5 tons
Width14-1/2 in
RefrigerantR-410A
MeteringPiston

4MXCA001AC6HCA: the 1.5 to 2.5 ton Ameristar coil for a home that is neither small nor huge

You have a furnace that still works, ductwork that reaches every room, and you are tired of hauling window air conditioners up to the second floor every June. The Ameristar 4MXCA001AC6HCA evaporator coil was designed for exactly that situation. It is a cased coil with a nominal size of 1.5 to 2.5 tons (30,000 BTU/h), it runs on R-410A refrigerant, and it sits on top of the furnace.

On its own, it does nothing: it needs an Ameristar outdoor unit of the same capacity. Once the two units are connected, the house gets cool air in summer. If the outdoor unit is a heat pump, it also gets heat in winter, through the same vents and the same ducts you have today.

Why this size suits mid-sized homes

A 1.5 to 2.5 ton coil sits in the middle of the range. It works well for two-storey homes with a properly insulated upper floor, bungalows with a partly finished basement, or townhouses in Laval and Longueuil where the heated area stays reasonable. It avoids the temptation of going "bigger, just in case".

An oversized unit keeps shutting off and starting up again. It cools quickly, but it dries the air poorly, and the house stays clammy despite the air conditioning. We prefer to measure before we recommend anything: windows, insulation, the number of rooms served by the ducts. The load calculation settles it, not a hunch.

What this coil does in your plenum

Think of the plenum as the crossroads where the furnace air heads out to the ducts. The coil is installed there, in the path of the air. In summer, cold refrigerant flows through its tubes and removes heat and moisture from the air passing over it. The water collected in the pan runs out through the 3/4 in NPT condensate drain.

The cabinet is insulated and arrives ready to install. For you, that means a cleaner installation and less air leakage around the unit than with a bare coil that gets wrapped on site.

An A shape, a width of 14-1/2 in

The coil is shaped like the letter A: two sloped faces meet at the top, and the air passes through them in turn. The cabinet measures 14-1/2 × 20 × 21 in, with a net weight of 40 lb. Nothing bulky, which helps when the furnace is tucked into a tight corner of the basement.

The manufacturer lists it as multipoise: upflow, downflow, or horizontal left or right. The same unit can therefore serve a furnace standing upright or lying down in a crawl space.

The key checkpoint is the width. If your furnace is not 14-1/2 in wide, we build an insulated transition on site. That is not a flaw in the product, just a routine part of the trade.

How it compares with the other models in the 4MXC series

Four models share this catalogue page. All use R-410A, and all have a piston-type metering device. What changes is the capacity and the width:

  • 4MXCA001AC6HCA (this one): 1.5 to 2.5 tons, 14-1/2 in wide.
  • 4MXCA003AC6HCA: 1.5 to 3 tons, same 14-1/2 in width. If your furnace is narrow but the house is a little bigger or harder to cool, this is the one we look at.
  • 4MXCB004AC6HCA: 1.5 to 3 tons, but 17-1/2 in wide. It is meant for wider furnaces.
  • 4MXCC009AC6HCA: 3.5 to 5 tons, 21 in wide, for large properties.

The practical rule: first choose the width that matches the furnace, then the capacity that matches the house. The 4MXCA001AC6HCA is a good fit when both answers are "narrow" and "medium".

Matching it with the outdoor unit

The coil is paired with an Ameristar outdoor unit of the same capacity and the same refrigerant. The coil and the outdoor unit are installed together, with R-410A. Before placing an order, we look up the exact match in the AHRI directory, and we keep the reference number for you.

Why so many precautions? Because the coil has no efficiency rating of its own. The SEER2, EER2 and HSPF2 ratings belong to the certified system, that is, to a specific combination of coil, outdoor unit and AHRI number. When two quotes look similar, that number tells you whether you are really comparing the same thing.

Add-on heat pump: the furnace stays in the picture

In this setup, your furnace keeps its blower, its filters and its heating elements. It becomes the backup heat for the coldest weather, and the outdoor unit does most of the work in mild weather. We set up with you the temperature threshold below which the furnace takes over.

The concrete result on your bill: an electric furnace turns every kilowatt-hour into an equal amount of heat, whereas a heat pump moves heat and, in mild temperatures, delivers two to three times more than the electricity it consumes. That efficiency drops when it gets very cold, which is why we keep the backup.

What we check before ordering

  • R-410A: the coil is paired with an outdoor unit using the same refrigerant. A replacement on an existing system requires us to confirm the refrigerant already in place.
  • The 14-1/2 in width against the width of your furnace.
  • The blower, which must deliver the system's airflow.
  • The electrical panel, for the outdoor unit's circuit.
  • The published ratings, which apply to the certified match and not to the coil alone.

4MXCA001AC6HCA specifications

  • Type: evaporator coil with cabinet, 4MXC range
  • Nominal size: 1.5 to 2.5 tons (30,000 BTU/h)
  • Refrigerant: R-410A
  • Metering device: piston
  • Connections: 3/8 in liquid, 3/4 in suction
  • Condensate drain: 3/4 in NPT
  • Dimensions W × H × D: 14-1/2 × 20 × 21 in
  • Net weight: 40 lb

Please note: Ameristar states that some certified combinations of this older-generation R-410A coil require a TXV kit ordered separately. We confirm this when we work out the match, not after delivery.

How it goes at your home, in Montreal and beyond

AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years. We work in Montreal, Laval, Longueuil, on the North Shore and on the South Shore. Refrigeration, ventilation and electrical work is carried out under our RBQ licence 5645-9605-01. A typical installation goes like this:

  • measuring the furnace and checking the blower and the panel;
  • installing the coil in the plenum, with a transition if needed, then sealing the connections;
  • installing the outdoor unit, brazed piping, nitrogen pressure test and vacuum;
  • connecting the drain and the thermostat;
  • commissioning, adjusting the airflow and walking the household through the system.

Frequently asked questions

Can this coil provide heat? Yes, if it is paired with a heat pump: it cools in summer and heats in winter. With a central air conditioner, it only provides cooling.

Can I keep my current air conditioner? Generally not. The coil runs on R-410A and must connect to the outdoor unit specified by the manufacturer. We install the complete system.

My furnace is a different width. What can I do? We measure it and, if needed, build an insulated transition.

Is the furnace still useful? Yes. It keeps its blower and takes over below the threshold we set together.

Hydro-Québec grants

Eligibility depends on the matched system, not on the coil alone. We check Hydro-Québec's official list according to the installation date and tell you what applies to your project, with no hasty promises.

Next step: a free estimate

Request your free in-home estimate. We measure the furnace, check the electrical service and give you a written quote for the complete Ameristar system. Financing is available to spread out the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The 4MXCA001AC6HCA sits in the plenum of a furnace or air handler. Connected to a matching Ameristar outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with a matching Ameristar outdoor unit
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-410A refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerAmeristar
Model4MXCA001AC6HCA
TypeCased evaporator coil
Line4MXC
Nominal size1.5 to 2.5 tons (30,000 BTU/h)
RefrigerantR-410A
Metering devicePiston
Liquid connection3/8 in
Suction connection3/4 in
Dimensions W × H × D14-1/2 × 20 × 21 in
Net weight40 lb
Model number4MXCA001AC6HCA
03 · Before installing

What to know before installing

  • R-410A refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 14-1/2 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
AMERISTAR
See all
05 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-410A and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 1.5 to 2.5-ton Ameristar coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.