AMERISTAR 4MXCA003AC6HCA Evaporator A-Coil | 1.5 to 3 Tons

In stock

The Ameristar 4MXCA003AC6HCA 1.5 to 3-ton R-410A cased coil sits on your furnace and, matched with a matching Ameristar outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model number4MXCA003AC6HCA

1.5 to 3 tons36,000 BTU/h nominal
14-1/2 inwidth
R-410Arefrigerant
R-410AAdd-on heat pumpCasedR-410A
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model number4MXCA003AC6HCA
ManufacturerAmeristar
Size1.5 to 3 tons
Width14-1/2 in
RefrigerantR-410A
MeteringPiston

The 4MXCA003AC6HCA: a 1.5 to 3 ton Ameristar coil for the narrow furnace

Changing seasons without changing ducts

Here is a simple way to explain this product: think about how your home lives through a full year. In January, the furnace blows. In July, you close the blinds and dream of a cooler upstairs. The Ameristar 4MXCA003AC6HCA evaporator coil is the part that lets the same air ductwork serve in both cases. It is a cased A-coil from the 4MXC range, with a nominal size of 1.5 to 3 tons (36,000 BTU/h), and it uses R-410A refrigerant.

Spring: the time to assess it

Visits are easy to schedule before the heat arrives. We come to your home in Montreal, Laval, Longueuil, on the North Shore or on the South Shore, and we look at the furnace, the access to the plenum and the electrical panel. We note the width of the furnace: this model is 14-1/2 in. If yours differs, an insulated transition is built on site.

What matters at this stage is the conversation about your habits. A room that is hard to cool, a damp basement, an upper floor that stays lukewarm: all of this feeds the load calculation that tells us whether 1.5 to 3 tons is the right range.

Summer: cool air in every room

As soon as the outdoor unit is running, refrigerant flows through the coil. The warm air from the house passes through it, gives up its heat and moisture, then heads back out to the ducts. The condensation falls into the pan and runs to the 3/4 in NPT drain. A single system replaces the window units, and the house becomes drier, which makes a big difference to how muggy days feel.

Winter: the heat pump takes over

With a central heat pump as the outdoor unit, the cycle reverses. The refrigerant picks up heat outside and gives it to the air passing through the coil. The furnace remains available: it keeps its blower and its filters and serves as backup on the harshest nights, according to the threshold we set with you.

For a homeowner who currently heats with electricity, this is where the value lies: the heat pump moves heat instead of making it, and in mild weather delivers two to three times more heat than the electricity it consumes.

The shape of the coil

Two sloped faces forming an A, an insulated cabinet, dimensions of 14-1/2 × 20 × 21 in, a net weight of 40 lb. The connections are 3/8 in on the liquid side and 3/4 in on the suction side. The metering device is a piston type: a calibrated orifice controls the flow of refrigerant to the coil, with no moving parts to maintain.

Ameristar lists several installation positions: upflow, downflow, or horizontal left or right. Depending on where the furnace is, we choose the one that keeps the drain properly sloped and the filter access clear.

The certified match, explained without jargon

A coil does not get an efficiency rating on its own. The rating belongs to a trio: a specific coil, a specific outdoor unit and the AHRI number that links them. That is where the published SEER2, EER2 and HSPF2 ratings are found. Before ordering, we confirm this number in the AHRI directory.

For you, the consequence is practical: when comparing two quotes, ask for the AHRI number of each. If the numbers differ, the efficiency figures cannot be compared. If one quote gives none, ask the question.

This model among its neighbours

In the 4MXC series, three other models exist. All use R-410A and a piston. Here is how to tell them apart:

  • 4MXCA001AC6HCA: 1.5 to 2.5 tons, 14-1/2 in. Same width as this one, a slightly lower capacity range, for mid-sized homes.
  • 4MXCA003AC6HCA (this page): 1.5 to 3 tons, 14-1/2 in. The choice for a narrow furnace and a house that needs a wider range.
  • 4MXCB004AC6HCA: 1.5 to 3 tons, 17-1/2 in. Same capacity range, wider cabinet.
  • 4MXCC009AC6HCA: 3.5 to 5 tons, 21 in. For large homes.

In other words, the 4MXCA003AC6HCA and the 4MXCB004AC6HCA have the same nominal capacity: only the width of the cabinet separates them. Your furnace decides, not your preference.

Points to clarify before buying

  • The coil runs on R-410A and is paired with an outdoor unit using the same refrigerant.
  • The published ratings apply to the matched system, never to the coil taken separately.
  • The coil is 14-1/2 in wide: we check the furnace before ordering.
  • The blower must deliver the system's airflow.
  • Ameristar states that some certified combinations of this older-generation coil require a TXV kit ordered separately. We check this for your match.

Technical sheet

  • Manufacturer: Ameristar, model 4MXCA003AC6HCA
  • Type: evaporator coil with cabinet
  • Nominal size: 1.5 to 3 tons (36,000 BTU/h)
  • Refrigerant: R-410A
  • Metering device: piston
  • Connections: 3/8 in liquid, 3/4 in suction
  • Condensate drain: 3/4 in NPT
  • Dimensions W × H × D: 14-1/2 × 20 × 21 in
  • Net weight: 40 lb

Why go with AirGreen

We are a family-owned heating and cooling company that has been based in Montreal for more than fifteen years. Refrigeration, ventilation and electrical work is done under RBQ licence 5645-9605-01. Our installation day includes measuring the furnace, checking the panel, installing the coil in the plenum, brazing the piping, the nitrogen leak test, the vacuum, connecting the drain and the thermostat, then commissioning with airflow adjustment.

Quick answers

Does it heat? Yes, with a heat pump. With a central air conditioner, the function is cooling.

Can my old air conditioner stay? Rarely. The outdoor unit must match the coil and the R-410A, and we install the whole set.

What happens to the furnace? It stays in place as backup heat.

Three home scenarios where it fits in

The seventies-era bungalow in Longueuil. Electric furnace in the basement, old sheet-metal ducts, a window air conditioner in every bedroom. The coil is added to the plenum, an outdoor unit goes on a pad behind the house, and the system replaces the window units and a good part of the electric heating all at once.

The Laval two-storey with a well-insulated upper floor. Cool air finally reaches the upstairs bedrooms, which the old portable units did poorly. The 1.5 to 3 ton range leaves some margin if the house gets a lot of afternoon sun.

The North Shore house expanded in stages. A living room addition, a half-finished basement: the load calculation says whether the nominal range is enough, or whether we need to look at the large size in the same series.

What we do not promise

We promise neither an efficiency rating without an AHRI number, nor a grant before we have checked the list, nor that a coil will save ducts in poor condition. We prefer a customer who knows exactly what they are buying to one who is surprised by the bill. If the ducts leak or are too narrow, we say so in the written quote.

Maintenance after installation

The coil needs little attention: a clean filter, a clear condensate drain, a glance at the cabinet insulation. We explain each step at commissioning, and we are happy to come back if the pan overflows or the air seems less cool than before.

Grants

Hydro-Québec programs apply to the complete system, never to the coil alone. When we prepare the quote, we check the match against the official list, according to the installation date, then explain what applies to your case.

Request an estimate

The on-site estimate is free: furnace measurements, a review of the electrical service, and a written quote for the complete Ameristar system. To spread out the expense, financing is offered.

01 · What it is for

The heat pump coil for your furnace

The 4MXCA003AC6HCA sits in the plenum of a furnace or air handler. Connected to a matching Ameristar outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with a matching Ameristar outdoor unit
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-410A refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerAmeristar
Model4MXCA003AC6HCA
TypeCased evaporator coil
Line4MXC
Nominal size1.5 to 3 tons (36,000 BTU/h)
RefrigerantR-410A
Metering devicePiston
Liquid connection3/8 in
Suction connection3/4 in
Dimensions W × H × D14-1/2 × 20 × 21 in
Net weight40 lb
Model number4MXCA003AC6HCA
03 · Before installing

What to know before installing

  • R-410A refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 14-1/2 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
AMERISTAR
See all
05 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-410A and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 1.5 to 3-ton Ameristar coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.