BOSCH BMAC4860CNTF Evaporator A-Coil | 4-5 Tons
The Bosch BMAC4860CNTF 4-5-ton R-410A cased coil sits on your furnace and, matched with a matching Bosch outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberBMAC4860CNTF
514 316-2973 · sales@airgreen.ca
Quick facts
Bosch BMAC4860CNTF: 4-5 tons and 21 in of width for larger furnaces
Some homes need more than a standard size: an enlarged cottage, a basement finished as a family room, a multi-storey property in Laval or on the South Shore. For those cases, the Bosch BMAC4860CNTF evaporator coil offers a nominal size of 4-5 tons (60,000 BTU/h). It is an A-coil with a cabinet that uses R-410A refrigerant and sits on top of a furnace or a blower cabinet.
Our team installs it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore. Here is what you need to know to tell whether this size suits your home, and when another choice is the wiser one.
The house comes before the capacity
A large coil solves nothing if the house cannot feed it. At this size, two things get checked first: the electrical service, which must accommodate the outdoor unit's circuit, and the air distribution network, which must handle the airflow the system calls for.
That is why we start the visit with the electrical panel and the blower, not with the catalogue. If the ducts are too narrow or the air struggles to move, we say so plainly. Sometimes two smaller systems serve the house better than one big one.
What comes in the box
The BMAC4860CNTF measures 21 × 30 in, with a net weight of 83 lb. It is a bulkier module than its smaller sibling, so you need room in the furnace area, along with a clear path to bring it in without damaging the staircase.
- liquid connection: 3/8 in;
- suction connection: 7/8 in;
- condensate drain: 3/4 in female NPT, primary and auxiliary, with two connections on each side of the pan;
- expansion device: TXV;
- positions: multipoise, meaning upflow, downflow, horizontal left and horizontal right.
The suction line, wider than on a 3-ton coil, is not a minor detail: it goes along with the larger refrigerant flow that this capacity requires.
A job that needs preparation
A coil of this size is not something to improvise on a heatwave morning. Before installation, we take the time to record the exact width of the furnace, the height available above the plenum and the clearance around the module. A taller cabinet can force a change to the duct outlet, and it is better to know that before anything is ordered.
We also look at the condition of the existing ducts. In many homes in Montreal and Longueuil, the main sections were sized for an older, more modest air conditioner. If the network chokes the air, the coil cools poorly and the blower strains. Fixing a duct section costs little compared with living with a system that does not deliver.
Homeowners on the North Shore often ask us the same question: does the electrical panel need to be upgraded? It depends on the outdoor unit chosen and on what the panel already feeds. We check on site and note it in the written quote, so there are no bad surprises on installation day.
How air and cooling move through it
At the heart of the module, two sloped faces meet at a point, like the letter A. Air coming from the furnace passes through this double wall. In summer, the refrigerant evaporates in the tubes, picks up heat from the air and lets the moisture condense; the water runs into the pan and leaves through the drain.
The TXV adjusts the feed to the coil according to the load. When the house heats up in the afternoon sun, it lets in more refrigerant; when demand drops, it lets in less.
Add-on heat pump: winter without scrapping the furnace
If the outdoor unit is a heat pump, the cycle reverses in winter. The refrigerant, warmed outdoors, gives up its heat to the air passing through the coil. The furnace keeps its blower, its filters and its heating elements; it steps in when the outdoor temperature falls below the threshold programmed with you.
For a large house, this is a concrete gain. In mild weather the heat pump delivers two to three times more heat than the electricity it consumes, and the furnace stays on hand as backup for the coldest periods.
Comparing with the BMAC3036BNTD
In the same Bosch BMAC line, the other choice is the BMAC3036BNTD, at 3 tons. The two models share the A-shape, the cabinet, R-410A and the TXV. What changes:
- Capacity: 4-5 tons here, 3 tons for the BMAC3036BNTD;
- Width: 21 in versus 17-1/2 in;
- Suction line: 7/8 in versus 3/4 in;
- Size: the BMAC3036BNTD is more compact and lighter to handle.
If your furnace is narrow or the house is mid-sized, the BMAC3036BNTD will be the more natural fit. The BMAC4860CNTF becomes relevant when the furnace is wider and the house calls for this capacity.
Efficiency ratings: what to demand in writing
A coil on its own has no efficiency rating. The SEER2, EER2 and HSPF2 ratings describe a complete system: a coil, an outdoor unit and an AHRI number that pairs them. To compare two quotes honestly, ask each contractor for that number.
We confirm the exact match before ordering. What Bosch publishes about this version is worth knowing:
- Bosch states that BMAC coils on R-410A are designed for the BOVA 2.0 heat pump, the BGH96 furnace (96% AFUE) or the SM Split geothermal module;
- no BMAC...NTD / NTF match is ENERGY STAR certified, and the Tecnico list shows no AHRI number;
- this R-410A version is now classed among discontinued products, replaced by the BMAC coils on R-454B.
What we do on installation day
AirGreen has been a family-run heating and cooling company in Montreal for more than fifteen years, and our refrigeration, ventilation and electrical work falls under our RBQ licence 5645-9605-01. For a coil of this size, our work follows these steps.
- Measuring the furnace and checking the blower and the electrical panel.
- Setting the coil in the plenum, with an insulated transition made on site if needed, and sealing the duct connections.
- Installing the outdoor unit on a pad or bracket, brazing the line set, pressure-testing with nitrogen and pulling a vacuum.
- Connecting the drain and the thermostat.
- Commissioning, setting the airflow and explaining the system at your home.
When two systems beat one
In a very large house, or one with an added wing and a floor far from the furnace, a single big system sometimes struggles to balance temperatures. The upstairs is too warm, the basement too cool. Two smaller systems, each with its own zone and thermostat, can be tuned more finely and protect comfort in every room.
We do not sell the highest capacity on principle. If your house is a poor fit for it, we will suggest another configuration, including the BMAC3036BNTD for one of the zones.
Quick answers
Can this coil provide heat? Yes, with a heat pump: cooling in summer, heating in winter. With a central air conditioner, cooling only.
Can I keep my current air conditioner? Generally not. The R-410A coil must be matched with the outdoor unit specified by the manufacturer, and we install the whole set.
Is the furnace still useful? Yes. It supplies the blower and backup heat below the threshold we set together.
Points to check before you buy
- R-410A suits a replacement on an existing system with the same refrigerant, which we check before ordering.
- Published ratings apply to the certified match with the specified outdoor unit.
- The furnace must have the right width and a blower able to deliver the system's airflow.
Government assistance
Hydro-Québec programs assess the complete system, not an isolated part. When we prepare the quote, we consult the official list and tell you what applies to your file, depending on the installation date.
Plan the visit
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Bosch system. Financing is available to spread out the cost of the project.
A 4-5 ton Bosch BMAC4860CNTF coil, installed by AirGreen, for homes that truly need this capacity.
The heat pump coil for your furnace
The BMAC4860CNTF sits in the plenum of a furnace or air handler. Connected to a matching Bosch outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching Bosch outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-410A refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 21 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
BOSCHSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-410A and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 4-5-ton Bosch coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.