COMFORTMAKER EVM5X49M21A Evaporator V-Coil | 4 Tons
The Comfortmaker EVM5X49M21A 4-ton R-454B cased coil sits on your furnace and, matched with the Comfortmaker Q5H9V48*K*AAA outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberEVM5X49M21A
514 316-2973 · sales@airgreen.ca
Quick facts
EVM5X49M21A: 4 tons, ENERGY STAR cold-climate match with the Q5H9V48*K*AAA
In Quebec, the real test of a heat pump does not come in July, but in January. That is what makes the Comfortmaker EVM5X49M21A evaporator coil interesting: among the seven EVM5X models on this page, it is one whose main outdoor unit, the Q5H9V48*K*AAA, is part of the matches that Comfortmaker states are certified ENERGY STAR cold climate.
It is a cased 4-ton (48,000 BTU/h) V-coil using R-454B refrigerant, which we install on furnaces in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.
What "cold climate" means for your bill
A heat pump loses capacity as the outdoor temperature drops. Models designed for the cold limit that loss. For the matched range, Comfortmaker lists a heating capacity at -8.3 °C that runs from 19,600 to 45,500 BTU/h depending on the match. The exact value depends on the outdoor unit chosen; we go over it with you before you sign.
In practical terms, the more capacity the heat pump keeps in cold weather, the less often the furnace has to take over. It stays there for the cold peaks, and it is the changeover threshold, programmed with you, that decides when.
The three published matches
- Q5H9V48*K*AAA, AHRI 217954486: cooling 47,000 BTU/h, heating 52,000 BTU/h at 47 °F, SEER2 15.2, HSPF2 9.0;
- N5H9V48*K*AAA, AHRI 217954481: cooling 47,000 BTU/h, heating 52,000 BTU/h at 47 °F, SEER2 15.2, HSPF2 9.0;
- C5H8T48*K*AAA, AHRI 216349393: cooling 48,000 BTU/h, heating 50,000 BTU/h at 47 °F, SEER2 16.5, HSPF2 7.8.
The first two are variable-speed heat pumps from the QuietComfort and Performance 19 SEER2 series. The last is a model from the C5H8T family. In all three cases, the AHRI number identifies the complete system: the coil has no efficiency rating of its own.
Note the difference between the figures: the last match shows a higher SEER2 but a lower HSPF2. For a home that heats more than it cools, HSPF2 is the figure to look at first.
Which model to choose in the series?
Let us compare the EVM5X49M21A with its six neighbours:
- EVM5X48M21A: same 4-ton size, same width, but the main outdoor unit is the B5H0V48*K*AAA, and the cabinet is shorter. It suits better when height is lacking.
- EVM5X43M21A and EVM5X44M21A: 3.5 tons, also 21 in, with the B5H3V36*K*AAA. Worth keeping in mind if the home's load is more modest.
- EVM5X60M21A: 5 tons, 21 in, same main outdoor unit as the 49M21A. If the house grows or the load is high, it is the next step up.
- EVM5X60M24A and EVM5X61M24A: 5 tons, wider (24-1/2 in), for wide furnaces.
The 49M21A is therefore the right choice for a 4-ton home with a furnace 21 in wide, where you want a heat pump designed for winter.
A cabinet 29-3/4 in high
Published dimensions: 21 × 29-3/4 in, with a net weight of 49.6 lb. The cabinet is taller than those of the EVM5X43M21A and EVM5X48M21A, which calls for a roomy plenum. We measure before ordering; if the height is borderline, we say so plainly and propose the shortest model that fits.
How the coil fits into a heat pump
In cooling, the refrigerant evaporates in the coil tubes and absorbs heat from the air in the house. In heating, the cycle is reversed: the refrigerant, warmed by the outdoor unit, releases its heat to the air passing through the coil. One important technical point: with a heat pump, the outdoor unit must have a piston expansion device in heating mode. The coil itself uses a TXV.
The condensate pan, in sloped PBT and fitted with three sealed plugs, carries away the water produced in cooling. The connections are 3/8 in (liquid) and 7/8 in (suction).
EVM5X49M21A sheet
- range: EVM5X, Comfortmaker;
- type: cased evaporator coil;
- nominal size: 4 tons (48,000 BTU/h);
- refrigerant: R-454B;
- positions: upflow, downflow or horizontal;
- leak detection: A2L sensor and complete dissipation system supplied or installed at the factory (sheet EVM5X-51-01PD);
- manufacturer warranty: 10 years on parts with registration within 90 days of installation, 5 years without registration.
Our assessment visit
Before proposing this system, we review the blower, the plenum and the return air. A 4-ton coil requires high airflow; if the furnace cannot supply it, we explain why and propose solutions. If the furnace width differs from 21 in, an insulated transition is built on site.
How the work unfolds
AirGreen is a family-owned heating and cooling company that has worked in Montreal for more than fifteen years, under RBQ licence 5645-9605-01. The job includes:
- measuring the furnace, checking the blower and the panel;
- installing the coil and sealing the duct connections;
- the outdoor unit on a pad or bracket, brazed piping, the nitrogen test, the vacuum;
- the drain and the thermostat;
- commissioning, airflow adjustment and explanations.
An example January day
In the morning, the thermostat calls for heat. The heat pump starts, the warmed air circulates in the same ducts as before and the house slowly rises in temperature, without the jolts of an electric resistance element. If the outdoor temperature plunges below the threshold set at installation, the furnace joins in or takes over. You have nothing to do: the thermostat manages the switching.
In spring, that same thermostat switches to cooling. The coil cools the air, the drain carries off the condensation and the house stays cool, from the basement to the upstairs bedrooms. One appliance to set, two seasons covered, and the chance to leave the window air conditioners in the garage from the first heat wave.
Why we keep the furnace
In an add-on system, the furnace keeps its blower, its filters and its heating elements. It becomes your safety net in deep cold. Rather than replacing everything, we add a layer of efficiency on top of equipment that still works.
Checks before you buy
- R-454B requires an outdoor unit using the same refrigerant, installed at the same time.
- The published ratings apply to the matched system, not to the coil alone.
- The available height must allow a 29-3/4 in cabinet.
- The furnace must have the right width and the right blower.
Comfortmaker
Comfortmaker is part of International Comfort Products (ICP), a Carrier subsidiary. Its EVM5X coils are intended for its heat pumps and central air conditioners.
LogisVert and Hydro-Québec
The matched Comfortmaker system appears on Hydro-Québec's list of eligible heat pumps. The amount varies with the installation date and your situation; we confirm it against the official list at the quote stage and prepare the application with you.
Planning your estimate
Call us for a free in-home estimate: we measure the furnace, check the electrical service and write a quote for the complete Comfortmaker system. Financing lets you spread the cost over time.
The heat pump coil for your furnace
The EVM5X49M21A sits in the plenum of a furnace or air handler. Connected to the Comfortmaker Q5H9V48*K*AAA outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the Comfortmaker Q5H9V48*K*AAA outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 21 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Explore the range
Evaporator coilsSee allSame brand
COMFORTMAKERSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 4-ton Comfortmaker coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.