COMFORTMAKER EVM5X60M21A Evaporator V-Coil | 5 Tons
The Comfortmaker EVM5X60M21A 5-ton R-454B cased coil sits on your furnace and, matched with the Comfortmaker Q5H9V48*K*AAA outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberEVM5X60M21A
514 316-2973 · sales@airgreen.ca
Quick facts
The Comfortmaker EVM5X60M21A: 5 tons in a 21 in width, for large homes with a narrow furnace
Three questions come up almost every time the owner of a large home calls us about a 5-ton coil: is the furnace wide enough? will the blower keep up? and what does this size change compared with the smaller ones? This page answers those three questions for the Comfortmaker EVM5X60M21A, a 5-ton (60,000 BTU/h) cased V-shaped evaporator coil with an insulated cabinet and R-454B refrigerant.
We install it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore, on furnaces and blower cabinets already in place.
First question: is the furnace wide enough?
This model is 21 in wide, like the EVM5X43M21A, EVM5X44M21A, EVM5X48M21A and EVM5X49M21A. That is what sets it apart from its two 5-ton cousins, the EVM5X60M24A and EVM5X61M24A, whose cabinets are 24-1/2 in wide. If your furnace is 21 in wide, the 60M21A fits it directly. If it is wider, we build an insulated transition, or we steer you toward a 24-1/2 in model depending on what the measurement shows.
Published dimensions: 21 × 29-3/4 in, net weight 49.6 lb. The cabinet is therefore fairly tall: we check the clearance above the furnace before any order.
Second question: will the blower keep up?
This is the decisive question. A 5-ton size calls for more airflow than any of the smaller sizes in the series. A worn-out blower, narrow return ducts or overly restrictive filters would make the coil frost up in summer. So during the visit we check the motor, the plenum size and the returns. Sometimes a small improvement to the distribution fixes everything; more rarely, we recommend a smaller size.
The multi-position coil accepts upflow, downflow or horizontal airflow: the direction of the air depends on your furnace, not on the coil.
Third question: what does the 5-ton size really change?
It increases the exchange surface available to the refrigerant, and that is useful when a large residence has many rooms and windows. But be careful: the coil size is not the output of the complete unit. The real capacity of a system also depends on the outdoor unit. See the published figures:
- Q5H9V48*K*AAA, AHRI 217954500: cooling 47,000 BTU/h, heating 52,000 BTU/h at 47 °F, SEER2 15.2, HSPF2 9.0;
- N5H9V48*K*AAA, AHRI 217954495: cooling 47,000 BTU/h, heating 52,000 BTU/h at 47 °F, SEER2 15.2, HSPF2 9.0;
- C5H8T48*K*AAA, AHRI 216349401: cooling 48,000 BTU/h, heating 50,000 BTU/h at 47 °F, SEER2 16.5, HSPF2 7.8.
In other words, the load calculation determines the outdoor unit; the 5-ton coil is sized to accompany it and to let the air through. Only the AHRI number, which links the two parts, is authoritative for the efficiency ratings.
Where the 60M21A sits in the series
- Smaller: the EVM5X43M21A and EVM5X44M21A (3.5 tons, matched with the B5H3V36*K*AAA) and the EVM5X48M21A and EVM5X49M21A (4 tons).
- Same size, wider: EVM5X60M24A and EVM5X61M24A, at 24-1/2 in.
To choose between the 60M21A and the 49M21A, look at the tonnage. With the same main outdoor unit (Q5H9V48*K*AAA), moving from 4 to 5 tons is justified by the volume of air to be handled, not by the capacity of the outdoor unit.
The technical facts at a glance
- type: cased evaporator coil, EVM5X range;
- expansion device: TXV;
- connections: 3/8 in liquid, 7/8 in suction;
- drain: sloped PBT pan and three sealed plugs;
- A2L leak detection and dissipation system installed or delivered with the unit, per sheet EVM5X-51-01PD;
- 10-year limited warranty on parts, with registration within 90 days of installation (5 years otherwise).
The coil's role in your furnace heat pump
Installed in the plenum, the coil receives the refrigerant from the outdoor unit. In summer, it picks up heat from the air; the condensation water is collected in the pan and carried to the drain. In winter, with a heat pump, the direction of the cycle changes and the outdoor heat is delivered to the air of the home. In a large residence, this distribution through ducts is a big advantage: you do not multiply wall-mounted units.
Comfortmaker states that the EVM5X matches with the Q5H9V and N5H9V heat pumps are certified ENERGY STAR cold climate. With a heat pump, the outdoor unit must have a piston expansion device in heating mode.
What a large home goes through in summer
In a large two-storey home, July heat builds up upstairs, in the south-facing bedrooms and in the home office. Window units are noisy there and leave lukewarm zones. A central system connected to this coil moves the air of the whole house through the existing registers. You set one thermostat, and the air is dried along the way, which eases the sticky, humid feeling.
In winter, the same duct network spreads the heat from the heat pump, keeping the furnace as backup in deep cold.
What we do not do
We do not choose a 5-ton coil out of habit, simply because the house is big. A coil too large for its system, or poorly supplied with air, costs more to buy and gives poorer comfort. That is why we start from the load calculation, then check the distribution, and only after that confirm the model. If the 4-ton is enough, we tell you, even if it lowers the quote.
Installation day
AirGreen is a family-owned heating and cooling company in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01. For this job, the crew:
- measures the furnace and checks the blower and the electrical panel;
- installs the coil in the plenum and seals the duct connections, with a custom transition if needed;
- sets the outdoor unit, brazes the piping, runs the nitrogen test and pulls the vacuum;
- connects the drain and the thermostat;
- commissions the system, adjusts the airflow and guides you through its use.
Before you sign
- R-454B requires an outdoor unit using the same refrigerant.
- The ratings apply to the certified matched system.
- Width of 21 in, height of 29-3/4 in and blower airflow: three measurements to confirm.
The brand
Comfortmaker belongs to International Comfort Products (ICP), a Carrier subsidiary. The EVM5X60M21A is designed for its heat pumps and central air conditioners.
LogisVert rebate
The matched Comfortmaker system is listed on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and on your situation. We check the official list when we prepare your quote and prepare the application with you.
Have your furnace assessed
Our on-site estimate is free: we measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. Financing helps spread out the cost of the project.
The heat pump coil for your furnace
The EVM5X60M21A sits in the plenum of a furnace or air handler. Connected to the Comfortmaker Q5H9V48*K*AAA outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the Comfortmaker Q5H9V48*K*AAA outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 21 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Explore the range
Evaporator coilsSee allSame brand
COMFORTMAKERSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 5-ton Comfortmaker coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.