GOODMAN CAPTA1818B3 Evaporator A-Coil | 1.5 Tons
The Goodman CAPTA1818B3 1.5-ton R-32 cased coil sits on your furnace and, matched with a matching Goodman outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberCAPTA1818B3
514 316-2973 · sales@airgreen.ca
Quick facts
Goodman CAPTA1818B3: 1.5 tons in a 17-1/2 in cabinet, for the mid-width furnace
Do you have a furnace that is a little wider than a condo's, but a home or unit that does not need much capacity? The Goodman CAPTA1818B3 coil exists for exactly that case. It pairs a 1.5-ton rating (18,000 BTU/h) with a cabinet 17-1/2 in wide, so the capacity stays modest while the footprint fits a wider furnace.
AirGreen installs it in Montreal, Laval, Longueuil and on the North Shore and South Shore. Read on to find out whether this model suits your home, or whether you should look at a neighbour in the line.
Two criteria, not one: capacity and width
Many people think a coil is chosen by tons alone. In reality, there are two separate questions. First: how much capacity does the house need? Second: what cabinet width suits the furnace installed in the basement? The CAPTA1818B3 answers the first with 1.5 tons and the second with 17-1/2 in.
Its published dimensions are 17-1/2 × 18 × 21 in (W × H × D). Width is what sets it apart from its twin, the CAPTA1818A3, which has the same capacity.
A visit to the furnace: what we measure
When we arrive at your home, we open the closet or utility corner and look at three things: the width of the plenum, the clearance above it and the furnace position (upflow or downflow). The coil works in upflow and downflow positions, which leaves some flexibility.
If the furnace is a little narrower or a little wider than the cabinet, we build an insulated transition on site. It is a common step, and it does not stop us from doing clean, airtight work.
The A shape, explained simply
Picture a pitched roof with two slopes. The two faces of the coil meet at the top, and the furnace air passes through both surfaces. This shape fits a lot of heat exchange surface into a compact space. It comes in an insulated cabinet: condensation is collected in the pan under the coil, then carried off by the drain.
What kind of home suits a 1.5-ton size?
Think of small, well-insulated single-storey houses, forced-air condos and plex units that have their own furnace. In these spaces, a modest capacity is enough and it gives better comfort: the unit runs longer and more quietly, and dries the air better than a system that starts and stops constantly.
Our role is to confirm that need through an assessment, not to sell the biggest unit. If the calculations show you need to go up a size, we will tell you.
Choosing between the CAPTA1818B3 and its neighbours
Here are the useful reference points, taken from the series data sheets:
- Same capacity, different width: the CAPTA1818A3 is 14 in wide. If your furnace is narrow, that is the one you need.
- Higher capacity, same width: the CAPTA2422B3 is offered in 17-1/2 in for 1.5 to 2 tons.
- Even more capacity: the CAPTA3022B3, for 2 to 2.5 tons, in the same 17-1/2 in width.
- Wider furnace: the 21 in models (CAPTA2422C3 and CAPTA3022C3) start at 1.5 to 2 tons.
In other words, the three "B3" models share the same cabinet width and differ only in capacity. That is handy if you are torn between two sizes: the furnace does not have to change.
Replacing an old central air conditioner: what really happens
If your home already has an ageing central air conditioner, people often assume you only need to change the outdoor unit. In practice, a coil designed for an older refrigerant cannot be paired with an R-32 unit. So we replace the whole set: the new coil in the plenum and the new unit outside. The piping is redone with care and checked with nitrogen before evacuation.
The benefit for you: one job site, one point of contact and a system whose parts were all chosen to work together.
R-32 refrigerant and TXV metering device
This coil runs on R-32 and must be paired with an outdoor unit using the same refrigerant. The metering device is a TXV: it adjusts the refrigerant flow in the coil according to the load. The connections are 3/8 in on the liquid side and 3/4 in on the suction side. An R-32 refrigerant sensor designed to last the life of the coil completes the set (sheet SS-DCoil-R32).
Summer comfort: humidity matters as much as temperature
Humid July heat wears you out more than dry heat. A well-sized system removes water from the air while it cools, which is why a modest, well-chosen capacity often gives a better result than an oversized unit. The thermostat controls the whole system, and the same ducts distribute the air to every room served.
Efficiency ratings: read the AHRI number
A coil has no efficiency rating on its own. Published values apply to the matched system and are tied to an AHRI number. On a quote, that number is the most reliable way to compare two offers. We confirm it before ordering so that the ratings are those of your actual installation.
What the Goodman warranty covers
The 10-year limited parts warranty applies, and online registration within 60 days of installation is not required in Quebec (Goodman sheet SS-GCoil-R32). The installation itself is covered by AirGreen.
Our work in Greater Montreal
A family-owned heating and cooling company in Montreal for more than fifteen years, AirGreen carries out its refrigeration, ventilation and electrical work under RBQ licence 5645-9605-01. For the CAPTA1818B3, here is the usual sequence:
- measuring the furnace, checking the blower and the electrical panel;
- setting the cabinet in the plenum, with a custom transition if needed;
- outdoor unit on a pad or bracket, brazed piping, nitrogen leak test, evacuation;
- condensate drain and thermostat;
- commissioning, airflow adjustment and a walkthrough.
A word about the blower
The coil adds resistance to airflow. The furnace blower must therefore be able to push the required airflow through the new coil and the existing ducts. We check this before ordering, then adjust the airflow at commissioning. It is a simple check, but it is what separates a quiet, even system from a noisy one that struggles.
What to check before you buy
- An R-32 outdoor unit, installed at the same time as the coil.
- A furnace whose width suits a 17-1/2 in cabinet.
- A blower able to deliver the system's airflow.
- Published ratings tied to the certified matched system, not to the coil alone.
Incentives and eligibility
Hydro-Québec programs are based on the complete system. We confirm eligibility based on the installation date, using the official list, and we explain what applies to your project.
Get a written quote
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Goodman system. Financing is available to spread out the cost of the project.
The heat pump coil for your furnace
The CAPTA1818B3 sits in the plenum of a furnace or air handler. Connected to a matching Goodman outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching Goodman outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 17-1/2 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
GOODMANSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 1.5-ton Goodman coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.