GOODMAN CAPTA2422B3 Evaporator A-Coil | 1.5 to 2 Tons
The Goodman CAPTA2422B3 1.5 to 2-ton R-32 cased coil sits on your furnace and, matched with a matching Goodman outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberCAPTA2422B3
514 316-2973 · sales@airgreen.ca
Quick facts
CAPTA2422B3: an installation day with the Goodman 1.5 to 2 ton coil in 17-1/2 in
Rather than drawing up a list of features, let's follow the Goodman CAPTA2422B3 evaporator coil through a typical installation day. It is a good way to understand what it is, where it goes and what it asks of your home. This 1.5 to 2 ton model (24,000 BTU/h) fits in a cabinet 17-1/2 in wide and runs on R-32.
It is meant for homeowners in Montreal, Laval, Longueuil, the North Shore and the South Shore whose furnace is an intermediate width.
Before the job: the measuring visit
It all starts a few days earlier. We open the furnace casing, measure the plenum and look at the condition of the electrical panel. The CAPTA2422B3 measures 17-1/2 × 22 × 21 in (W × H × D): we check that these dimensions fit where planned, that the height is available and that the blower can deliver the system's airflow.
If the furnace width does not match exactly, we plan an insulated transition built on site. No surprises on installation day.
Early morning: the outdoor unit
The first step happens outside. The outdoor unit is installed on a pad or bracket, in a clear spot. It is chosen to match this coil: same refrigerant (R-32) and a neighbouring capacity. The two parts form a matched system identified by an AHRI number that we confirmed before the order.
Midday: the coil in the plenum
Inside, the insulated cabinet is set on the furnace. It works in upflow or downflow positions, depending on the orientation of the unit. Its liquid line connection is 3/8 in and its suction connection is 3/4 in. The copper piping is brazed between the outdoor unit and the coil, then tested with nitrogen to confirm it is leak-tight.
The metering device is a TXV. It meters refrigerant according to demand; you will never have to touch it.
Late afternoon: vacuum, drain and thermostat
Once the circuit is sealed, we pull a vacuum, connect the condensate drain and wire the thermostat. The R-32 refrigerant sensor, designed to last the life of the coil (sheet SS-DCoil-R32), is already built in. We then start the system and adjust the airflow.
What this capacity size serves best
The 1.5 to 2 ton range suits townhouses, bungalows and plex units that have their own forced-air system. It is large enough to get through a humid summer without the unit running at full capacity, and modest enough to avoid the short cycles of an oversized system.
Placing it in the series: CAPTA2422B3 compared with its neighbours
- Same capacity, narrower: the CAPTA2422A3 is 14 in wide.
- Same capacity, wider: the CAPTA2422C3 goes to 21 in.
- Same width, less capacity: the CAPTA1818B3 offers 1.5 tons in 17-1/2 in.
- Same width, more capacity: the CAPTA3022B3 goes up to 2 to 2.5 tons.
The logic is that of a two-way table: capacity in one direction, width in the other. This model sits in the middle square for both.
Air conditioning in summer, heating in winter
Paired with a heat pump, this coil lets you heat in winter through the existing ducts. The furnace becomes the backup heat in extreme cold, at a threshold we set with you. In summer, the coil cools the air and collects humidity in the condensate pan.
If you are replacing an old central air conditioner, the good news is that the duct network gets used again. Nothing to drill through the walls.
That same evening: what changes in the house
When the system starts up, the first sign is the quality of the air at the vents: cooler, drier and distributed more evenly. The noise of the outdoor unit stays outside, and the furnace blower does the rest of the work indoors. We walk you through the thermostat and answer your questions about the filter and the drain.
The next day, you will probably not have to think about it anymore. That is the goal: equipment that fades into the background behind the comfort it provides.
A concrete example: the South Shore bungalow
Picture a bungalow whose basement is used mostly for storage and whose furnace is a mid-range width. The owner wants air conditioning without running new ducts, and wants to cut what the electric furnace costs in winter. A mid-width cabinet and a 1.5 to 2 ton capacity fit that profile without excess. That is typically where the CAPTA2422B3 fits.
What we do not promise
We do not quote you a percentage of savings before we have seen your home. The real gain depends on insulation, air tightness, the current heating system and the matched system chosen. What we give you is a written quote, a verified AHRI number and a clean installation.
Why install everything at the same time
An R-32 coil does not accept just any outdoor unit: the two parts must share the same refrigerant and form a recognized matched system. That is why we install both on the same day, with a single set of new piping. That way you avoid paying for labour twice and you end up with a system in which every component has been verified, from the nitrogen leak test to the airflow adjustment.
If a contractor offers to replace only the outdoor unit, ask about the refrigerant and the AHRI number. The answer says a lot about the quality of the quote.
Efficiency: what a coil says (and does not say)
The coil has no efficiency rating of its own; the figures displayed belong to the certified set. That is why we never give you a rating without the AHRI number that backs it. If you are comparing quotes, ask each contractor to provide it.
Manufacturer's warranty
Goodman's 10-year limited warranty covers parts. Online registration within 60 days of installation is not required in Quebec (Goodman sheet SS-GCoil-R32).
Who works at your home
AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is done under RBQ licence 5645-9605-01. You know who you are talking to from start to finish of the project.
Points to confirm before buying
- R-32 requires an outdoor unit with the same refrigerant, installed at the same time.
- The 17-1/2 in cabinet has to suit your furnace, with a transition if needed.
- The blower has to deliver the required airflow.
- Published ratings are tied to the certified system.
Incentives
Hydro-Québec programs assess the complete system, not the coil alone. We check the official list based on the installation date and spell out what applies to your file.
Take the next step
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Goodman system. Financing is available to spread out the cost of the project.
The heat pump coil for your furnace
The CAPTA2422B3 sits in the plenum of a furnace or air handler. Connected to a matching Goodman outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching Goodman outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 17-1/2 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
GOODMANSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 1.5 to 2-ton Goodman coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.